background image

2-wire Heat Only

3-wire Cool Only

3-wire Heat Only

THERMOSTAT

G

W

Y

RH

RC

Heat Relay
or Valve

Heat
Transformer

THERMOSTAT

G

W

Y

RH

RC

Heat Relay
or Valve

Heat
Transformer

Fan
Relay

THERMOSTAT

G

W

Y

RH

RC

Cool
Contactor

Fan
Relay

Cool
Transformer

Содержание 44150

Страница 1: ...Owner s Manual S I N C E 1 8 8 6 44150...

Страница 2: ...Other Quality Products from Hunter Fans Humidifiers Air Purifiers...

Страница 3: ...k you for buying a Hunter product Table Of Contents Installation Operation Features 6 Remove Old Thermostat 8 Labeling Wires 10 System Selector Switches 14 Connecting Wires and Mounting Thermostat 14...

Страница 4: ...ter Thermostat is designed to operate with most gas oil electric or 2 wire hot water heating and air conditioning systems that have 24 volt or millivolt control This Hunter Thermostat will not control...

Страница 5: ...WARNING 8When the batteries are low LOW BATT indicator on the display will flash When this happens install new batteries immediately Once the LOW BATT indicator appears the thermostat will continue to...

Страница 6: ...y door for easy access Soft touch programming buttons see below Display shows time day temperature program number hold usage and low battery indicator Reset button for resetting computer back to 12 00...

Страница 7: ...display to current time and temperature Automatically programs the thermostat for weekday and weekend program settings For entering day of week Provides permanent temperature setting by overriding sto...

Страница 8: ...be labeled prior to removal IMPORTANT Turn off the power to the furnace at the main power panel or at the furnace Remove existing thermostat cover and thermostat See Figure 1 Some thermostats will ha...

Страница 9: ...TYPICAL HOME THERMOSTATS FIGURE 1 Wall Mounting Plate Thermostat Cover Wall Mounting Plate Thermostat Cover...

Страница 10: ...ect the other wire to the W terminal to complete the circuit IMPORTANT BEFORE DISCONNECTING ANY WIRES APPLY THE SELF ADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN TABLE A ON PAGE 11 For example att...

Страница 11: ...hermostat is RH R VR or 4 24 Volt G or F Fan RC VC 24 Volt Cool Y C or M See Note Air Conditioning W or H Heating RED BLUE GREEN YELLOW WHITE This table will help you match the labels to the wires so...

Страница 12: ...terminals Otherwise if you have separate RH and RC wires 5 wire system then remove the jumper wire between the RH and RC terminals NOTE Do not connect a Common wire sometimes labelled C to any termin...

Страница 13: ...vel for appearance Mark holes for plastic anchors provided if existing holes do not line up with Hunter Thermostat holes Drill holes with 3 16 bit and gently tap anchors into the holes until flush wit...

Страница 14: ...ect in the cooling mode NOTE HG position is for gas and most other systems HE position is for certain electric systems having a fan relay F C selector Fahrenheit Centigrade Your thermostat is set for...

Страница 15: ...ermostat body to snap it into the wallplate NOTE Do not force the thermostat onto the wallplate as the terminal pins may be damaged If it does not snap properly the thermostat may not work Insert the...

Страница 16: ...in heat mode and 78 25 C in cool mode Press the reset button after installing new batteries The first data you should enter is the current time and day of week As the keys are pressed the display will...

Страница 17: ...e If return is not pressed it will return automatically in 10 seconds HOUR MIN DAY RETURN M T W TH F SA SU SET TEMP HOLD TEMP I9 00 72c AM PM HEAT COOL 1234 FILTER LO BAT M T W TH F SA SU SET TEMP HOL...

Страница 18: ...fuel bill up to 25 Your thermostat is capable of holding up to 4 separate programs for heat or cool for weekdays and 4 seperate programs for each weekend day A typical set of programs is shown in Tabl...

Страница 19: ...or 78 F 20 C or 25 C right away use the temporary manual override feature described on page 26 to enter your desired temperature setting When your program becomes effective at the next time temperatu...

Страница 20: ...an revise your records each time you change your temperature settings Personal Program Schedule FOR WINTER FOR SUMMER PROGRAM WAKE LEAVE RETURN SLEEP NUMBER 1 2 3 4 MON TIME TIME TIME TIME thru FRI TE...

Страница 21: ...anual method of programming Press Your thermostat will be programmed automatically according to Table 3 If the slide switch is in the heat mode only heat program is effective In order to activate cool...

Страница 22: ...PM HEAT COOL 1234 FILTER LO BAT M T W TH F SA SU SET TEMP HOLD TEMP 80 00 68c AM PM HEAT COOL 1234 FILTER LO BAT Press and hold until 6 00 is displayed Weekday Program 1 is complete Note AM PM HOUR M...

Страница 23: ...M T W TH F SA SU SET TEMP HOLD TEMP 86 00 69c AM PM HEAT COOL 1234 FILTER LO BAT Use to insert or change time and temperatures of other programs HOUR MIN PROG PROG HOUR MIN PROG M T W TH F SA SU SET...

Страница 24: ...nue pressing to review programs NOTE The temperatures you have entered will NOT take effect immediately but at the next program time change The Thermostat is pre set to 68 F in heat mode and 78 F in c...

Страница 25: ...room temperature as 68 F If held for more than 2 seconds you will manually override your present temperature to a new setting as explained below M T W TH F SA SU SET TEMP HOLD TEMP 86 70 68c AM PM HEA...

Страница 26: ...sing arrow After 2 seconds the set temperature digits will blink and begin to increase until the button is released at the desired setting in this case 70 F Program number flashes Press return or in 1...

Страница 27: ...EAR until program number appears HOLD will disappear if you were in permanent manual override From temporary or permanent manual override state NOTE You can also return the current program by pressing...

Страница 28: ...ER LO BAT FILTER RESET 28 29 The Hunter Digital Thermostat measures and stores the amount of time the heating or air conditioning system operated After 500 hours of usage the word FILTER will appear a...

Страница 29: ...e Span Press Your thermostat comes with an electrolumi nescent lamp for easy viewing of the display in the dark To activate press the light button between the up and down arrow keys The display will r...

Страница 30: ...TO FAN DOES NOT COME ON 1 Remove clear mylar sticker 1 Check battery connections and batteries 2 Press reset button once with a small pin and hold in for two seconds 1 Replace batteries 1 Check that t...

Страница 31: ...on wait and check 3 Check your circuit breakers and switches to ensure there is power to the system 4 Replace batteries 5 Make sure your furnace blower door is closed properly 6 If your system only u...

Страница 32: ...ol System 5 wire Heat Cool System THERMOSTAT G W Y RH RC Heat Relay or Valve Heat Cool Transformer Fan Relay Cool Contactor Jumper THERMOSTAT G W Y RH RC Heat Relay or Valve Heat Transformer Fan Relay...

Страница 33: ...Cool Only 3 wire Heat Only THERMOSTAT G W Y RH RC Heat Relay or Valve Heat Transformer THERMOSTAT G W Y RH RC Heat Relay or Valve Heat Transformer Fan Relay THERMOSTAT G W Y RH RC Cool Contactor Fan...

Отзывы: