3

42693-01  •  11/11/09  •  Hunter Fan Company

7’ Minimum 

Blades to 

Floor

8’ Minimum 

Ceiling 

Height

30” From 

Wall or 

Nearest 

Obstruction

Step 1 - Choose the Fan Site

Proper ceiling fan location and attachment to the building 
structure are essential for safety, reliable operation, maximum 
efficiency, and energy savings.

Choose a fan site where:

• No object can come in contact with the rotating fan blades during 

normal operation.

• The fan blades are at least 7 feet above the floor and the ceiling is 

at least 8 feet high.

• The fan blades have no obstructions to airflow, such as walls or 

posts, within 30 inches of the fan blade tips.

• The fan is directly below a joist or support brace that will hold the 

outlet box and the full weight of the fan.

Checklist for Existing Fan Site

If you want to use an existing fan site, complete the following checklist to 

determine if the site is acceptable and safe for your new Hunter fan. If you 

cannot check off every item, prepare a new fan site as described on this 

page.

Fan Support System

• 

Fan attaches directly to building structure.

• Fan support system will hold full weight of the fan and light kit.

Ceiling Hole

• The outlet box clearance hole is directly below the joist or support brace.

Outlet Box

• The outlet box is an UL-approved octagonal 4” x 1-1/2” outlet box (or as 

specified by the support brace manufacturer).

• The outlet box is secured to the joist or support brace by wood screws 

and washers through the inner holes of outlet box.

• The outer holes of the outlet box are aligned with joist or support brace.
• The bottom of the outlet box is recessed a minimum of 1/16” into 

ceiling.

Wiring

• The electrical cable is secured to outlet box by an approved connector.
• Six inches of lead wires extend from outlet box.
If your existing fan site is suitable, skip ahead to Section 

2 • Installing the 

Ceiling Plate.

Suitable Existing Fan Site

Fan Support 

System

Fan Support 

System

Wiring

Outlet Box

Preparing the Fan Site

Содержание 42693-01

Страница 1: ...lso attach your receipt or a copy of your receipt to the manual __________________________________________ Model Name __________________________________________ Model No ______________________________...

Страница 2: ...unter nameplate label located on the top of the fan motor housing CautionsandWarnings READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS Use only Hunter replacemen...

Страница 3: ...eptable and safe for your new Hunter fan If you cannot check off every item prepare a new fan site as described on this page Fan Support System Fan attaches directly to building structure Fan support...

Страница 4: ...2 outlet box plus two 8 x 1 1 2 wood screws and washers available from any hardware store or electrical supply house 4 2 Orient the outlet box so that both the inner and outer holes in the box align...

Страница 5: ...cluded with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans...

Страница 6: ...er height dependent upon installation site CheckingYourFanParts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor...

Страница 7: ...ll four isolators are in place and were not removed during shipment 2 3 Place a flat washer on each of the two 3 wood screws 2 4 Thread the supply wires from the outlet box in the ceiling through the...

Страница 8: ...embled do not remove the downrod For Low Profile mounting Note For low profile mounting the downrod is replaced with the low profile washer 3 4 Remove the setscrew from the adapter 3 5 Place the low p...

Страница 9: ...r low profile washer 4 4 Using the large wire connector connect the white wires and the black wires from the ceiling as follows The white common power wire from the ceiling to the white wire from the...

Страница 10: ...y to operate this equipment Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interfer...

Страница 11: ...canopy screws into the holes opposite the ceiling plate tabs 6 4 Partially install a canopy screw into the hole between the two ceiling plate tabs When all the holes are properly aligned securely tig...

Страница 12: ...slightly loose after screws are tightened This is normal 7 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to s...

Страница 13: ...housing assembly screws 8 4 Turn the housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing...

Страница 14: ...and damage to the product 8 7 Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to...

Страница 15: ...Thread the fan pull chain through the grommet hole in the side of the cover plate 8 11 Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl 8 12 Thread th...

Страница 16: ...e from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull the thin plug connector male through first and t...

Страница 17: ...ith a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft 9 5 For cleaning fin...

Страница 18: ...the light off and on 10 2 Use the Light buttons to turn the Light On and Off 10 3 Use the Fan buttons to turn the Fan On and Off 10 4 When necessary replace the battery with a 12 volt type 23A MN 21...

Страница 19: ...an very carefully and check that the hanger ball is properly seated In compliance with U S Federal regulations this ceiling fan contains a wattage saver that limits the light output to 190 Watts The f...

Отзывы: