Table Of Contents

Preparing the Fan Site

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

1 • Getting Ready

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6

2 • Installing the Ceiling Plate

  .  .  .  .  .  .  .  .  .  . 7

3 • Assembling and Hanging the Fan

  .  .  . 8

4 • Wiring the Fan

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9

5 • Setting the Remote Transmitter                      

and Receiver

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

6 • Installing the Canopy and Canopy                 

Trim Ring

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11

7 • Assembling the Blades

 .  .  .  .  .  .  .  .  .  .  .  .  .  . 12

8 • Completing Your Installation With or 

Without a Bowl Light Fixture

  .  .  .  .  .  . 13

9 • Operating and Cleaning Your                     

Ceiling Fan

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 17

10 • Operating the Remote Control

  .  .  .  . 18

11 • Troubleshooting

  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 19

© 2009 Hunter Fan Company

Your new Hunter

®

 ceiling fan is an addition to your home or office that 

will provide comfort and performance for many years. This installation 
and operation manual gives you complete instructions for installing 
and operating your fan.

We are proud of our work. We appreciate the opportunity to supply 
you with the best ceiling fan available anywhere in the world.

Before installing your fan, for your records and warranty assistance, 
record information from the carton and Hunter nameplate label 
(located on the top of the fan motor housing).

Cautions and Warnings

 READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING 

INSTALLATION.  SAVE THESE INSTRUCTIONS.

• Use only Hunter replacement parts.
• To reduce the risk of personal injury, attach the fan directly to the 

support structure of the building according to these instructions, 
and use only the hardware supplied.

• To avoid possible electrical shock, before installing your fan, 

disconnect the power by turning off the circuit breakers to the 
outlet box and associated wall switch location. If you cannot lock 
the circuit breakers in the off position, securely fasten a prominent 
warning device, such as a tag, to the service panel.

• All wiring must be in accordance with national and local electrical 

codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a 
qualified electrician.

• To reduce the risk of personal injury, do not bend the blade 

attachment system when installing, balancing, or cleaning the fan. 
Never insert foreign objects between rotating fan blades.

• To reduce the risk of fire, electrical shock, or motor damage, do not 

use a solid-state speed control with this fan. Use only Hunter speed 
controls.

Welcome

Содержание 42693-01

Страница 1: ...lso attach your receipt or a copy of your receipt to the manual __________________________________________ Model Name __________________________________________ Model No ______________________________...

Страница 2: ...unter nameplate label located on the top of the fan motor housing CautionsandWarnings READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS Use only Hunter replacemen...

Страница 3: ...eptable and safe for your new Hunter fan If you cannot check off every item prepare a new fan site as described on this page Fan Support System Fan attaches directly to building structure Fan support...

Страница 4: ...2 outlet box plus two 8 x 1 1 2 wood screws and washers available from any hardware store or electrical supply house 4 2 Orient the outlet box so that both the inner and outer holes in the box align...

Страница 5: ...cluded with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans...

Страница 6: ...er height dependent upon installation site CheckingYourFanParts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor...

Страница 7: ...ll four isolators are in place and were not removed during shipment 2 3 Place a flat washer on each of the two 3 wood screws 2 4 Thread the supply wires from the outlet box in the ceiling through the...

Страница 8: ...embled do not remove the downrod For Low Profile mounting Note For low profile mounting the downrod is replaced with the low profile washer 3 4 Remove the setscrew from the adapter 3 5 Place the low p...

Страница 9: ...r low profile washer 4 4 Using the large wire connector connect the white wires and the black wires from the ceiling as follows The white common power wire from the ceiling to the white wire from the...

Страница 10: ...y to operate this equipment Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interfer...

Страница 11: ...canopy screws into the holes opposite the ceiling plate tabs 6 4 Partially install a canopy screw into the hole between the two ceiling plate tabs When all the holes are properly aligned securely tig...

Страница 12: ...slightly loose after screws are tightened This is normal 7 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to s...

Страница 13: ...housing assembly screws 8 4 Turn the housing counterclockwise until the housing assembly screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing...

Страница 14: ...and damage to the product 8 7 Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to...

Страница 15: ...Thread the fan pull chain through the grommet hole in the side of the cover plate 8 11 Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl 8 12 Thread th...

Страница 16: ...e from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull the thin plug connector male through first and t...

Страница 17: ...ith a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft 9 5 For cleaning fin...

Страница 18: ...the light off and on 10 2 Use the Light buttons to turn the Light On and Off 10 3 Use the Fan buttons to turn the Fan On and Off 10 4 When necessary replace the battery with a 12 volt type 23A MN 21...

Страница 19: ...an very carefully and check that the hanger ball is properly seated In compliance with U S Federal regulations this ceiling fan contains a wattage saver that limits the light output to 190 Watts The f...