background image

©2008 HUNTER FAN CO. 

43055-01   20081106

3

SAFETY INSTRUCTIONS

Thank you for purchasing the HUVC Air Purifier from Hunter Fan Company. You have 

purchased our latest development in portable air purification which has been designed to improve 

the quality of the air that you breathe. The following innovative features are included in your Hunter 

Air Purifier.

• High Particulate Efficiency: The HEPAtech® filter will remove 99.97% of 0.1 micron particles from 

the air that passes through the filter.

• 

Odor Removal

: The activated carbon Pre-Filter helps remove odors such as cooking, smoke, and 

pet smells from the air. It also traps lint, hair, and other large particles to help extend the life and 

performance of the HEPAtech® filter.

• 

Ionizer

: The ionizer improves the quality of air in the room by releasing negative ions into the air 

that attract positively charged dust, smoke, and pollen particles.

• 

UVC Lamp

: This Hunter Air Purifier is equipped with a UVC germicidal lamp. UVC technology is a 

proven germicide that is accepted by the FDA and EPA as having the ability to kill pathogens in air 

that is exposed to UVC light.

• 

Filter Counters

: Filter maintenance is critical to the performance of the Air Purifier. To help you 

determine when to change the  filters, the Pre-Filter and HEPAtech® filter, the unit has built in life 

counters that keep track of the life remaining of each filter.

       

WARNING

: This Air Purifier emits UV radiation that may cause eye and/or skin irritation. RG-3. 

Avoid exposing eyes and skin to unshielded UVC Lamp. 

       Caution

: The UVC Lamp may shatter and cause injury if it is dropped or sustains impact. Wear 

safety glasses and gloves when handling the UVC Lamp. Do not use excessive force when handling 

the UVC Lamp. Dispose of the UVC bulb in accordance with local or State guidelines as trace 

amounts of Mercury are present.

IMPORTANT!

READ ALL INSTRUCTIONS BEFORE USING THIS AIR PURIFIER.

1. This Air Purifier is designed for use on a flat level floor and may not work properly on an uneven 

floor. ALWAYS place the Air Purifier on a firm level floor. ALWAYS place the Air Purifier at least six 

(6) inches away from walls and heat sources such as stoves, radiators, or heaters.

2. Place the Air Purifier in an area that is out of the reach of children.

3. Before using the Air Purifier, extend the cord and inspect for any signs of damage. DO NOT use 

the product if the cord has been damaged.

4. This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug  

will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the 

plug. If the plug still does not fit, contact a qualified electrician. DO NOT attempt to defeat or over-

ride this safety feature.

5. ALWAYS UNPLUG the Air Purifier while it is being cleaned.

6. DO NOT move or tilt the Air Purifier while it is in operation. Turn off and unplug before moving.

7. DO NOT immerse the Air Purifier in water at any time because permanent damage will occur. To 

properly clean your Air Purifier, follow the instructions in the Maintenance section of this manual 

(pg. 10).

8. This equipment should be inspected frequently and collected dirt removed from it regularly to 

prevent excessive accumulation that could result in flashover or risk of fire.

READ AND SAVE THESE INSTRUCTIONS

!

Содержание 30790

Страница 1: ...HEPAtech UVC HEPAtech UVC HEPAtech UVC Form 43055 01 20100610 2010 HUNTER FAN CO English Germicidal Air Purifier Owner s Guide Models 30790 30791...

Страница 2: ...Keys 5 Operation Initial Operation 6 Filter Life Counters 8 Resetting the Air Purifier 8 Using the Ionizer 8 Air Purifier Maintenance Cleaning Your Air Purifier 9 Changing the Pre Filter 9 Changing t...

Страница 3: ...may shatter and cause injury if it is dropped or sustains impact Wear safety glasses and gloves when handling the UVC Lamp Do not use excessive force when handling the UVC Lamp Dispose of the UVC bulb...

Страница 4: ...s are collected Next the air passes through the UVC Field which helps reduce airborne pathogens such as germs viruses mold and mildew Then the ionizer releases negative ions into the air that attract...

Страница 5: ...esets the HEPAtech Filter Life Counter resets the UVC Lamp Life Counter IONIZER KEY Turns the Ionizer on and off UVC KEY Turns the UVC on and off UVC Key Pre Filter Reset Key Filter Reset UVC Lamp Res...

Страница 6: ...ingers under the handle on the Grill and pull forward then up Refer to Figs 4 and 5 3 Next check the HEPAtech filter by pressing firmly on all four corners of the Filter to ensure that it is fully ins...

Страница 7: ...ive turbo clean Fig 6 Fig 7 purifier base 6 Plug the unit into a 120V electrical outlet and turn the Speed Knob The unit will start with a low blower speed 7 Use the Speed Knob to adjust the blower sp...

Страница 8: ...nstructions on how to reset the counters Resetting the Air Purifier In the unusual situation that the unit or the display is exhibiting erratic behavior you may want to reset the Air Purifier If you s...

Страница 9: ...p extend the life of the HEPAtech filter Refer to Obtaining Replacement Filters pg 14 if you need help finding replacement filters 1 First turn off and unplug the Air Purifier 2 Next remove the Front...

Страница 10: ...p Refer to Figs 4 and 5 pg 6 3 Gently pull on the Filter to remove it from the unit While removing the Filter note the directional arrows printed on the top of the Filter The new Filter will be instal...

Страница 11: ...lacement UVC Lamps Change the UVC Lamp after 8000 hours approximately 1 year of use or every other time you replace the HEPAtech Filter To change the UVC Lamp 1 First turn off and unplug the Air Purif...

Страница 12: ...ove the Lamp from the unit Refer to Fig 13 NOTE HANDLE THE UVC LAMP CAREFULLY IT MAY SHATTER IF IT IS DROPPED DISPOSE OF THE UVC BULB IN ACCORDANCE TO LOCAL OR STATE REQUIREMENTS AS TRACE AMOUNTS OF M...

Страница 13: ...Press the filter firmly into the Air Purifier To avoid damaging the filter media you should press on the frame of the filter only Refer to page 12 NOTE THIS UNIT WILL NOT OPERATE UNLESS FILTER IS INST...

Страница 14: ...on pg 8 Changing the Pre Filter on pg 10 and Changing the Filter on pg 11 4 Unit has reduced air flow or increased noise The filter is clogged and should be changed Refer to Changing the Filter on pg...

Страница 15: ...if the air purifier is not purchased and used in the USA or Canada This warranty excludes and does not cover defects malfunctions or failures of the Air Purifier which were caused by repairs by person...

Страница 16: ...a and Taiwan Programmable Thermostat M AM 4 TEMP SOME AMERICAN STATES AND CANADIAN PROVINCES DO NOT ALLOW THE EXCLUSION OR INVALIDITY OF EXPRESS OR IMPLIED WARRANTIES IF THE USER CEASES TO OWN THE AIR...

Страница 17: ...2008 HUNTER FAN CO 43055 01 20081106 17 HEPAtech UVC HEPAtech UVC HEPAtech UVC Form 43055 02 20100610 2010 HUNTER FAN CO Espa ol Purificador de aire germicida Manual del propietario Modelos 30790 3079...

Страница 18: ...clas de control 21 Operaci n Operaci n inicial 22 Contadores de vida de filtro 24 Restableciendo el purificador de aire 24 Uso del ionizador 24 Mantenimiento del purificador de aire Limpieza de su pur...

Страница 19: ...recauci n L mpara UVC puede romperse y causar lesiones si se cae o recibe un impacto Use lentes de seguridad y guantes al manipular la l mpara UVC No use fuerza excesiva al manipular la l mpara UVC De...

Страница 20: ...mo g rmenes virus moho y hongos Luego el ionizador libera iones negativos en el aire que atraen el polvo el humo y las part culas de polen cargados positivamente Finalmente el aire purificado y limpio...

Страница 21: ...contador de vida til del filtro HEPAtech restablece el contador de vida til de la l mpara UVC TECLA IONIZADOR Enciende y apaga el ionizador BOT N UVC Enciende y apaga la l mpara UVC BOT N UVC Restable...

Страница 22: ...re Despu s de seguir esta orientaci n inicial contin e leyendo este folleto para aprender a operar las funciones m s avanzadas de su purificador de aire Operaci n b sica del purificador de aire 1 Reti...

Страница 23: ...tro de la rejilla delantera con cinta tipo gancho Aseg rese que cubra adecuadamente los conductos de ventilaci n de la rejilla Podr notar que se desprenden part culas de color negro del pre filtro Esa...

Страница 24: ...nes sobre c mo restablecer los contadores Restablecimiento del purificador de aire En la poco com n situaci n que la unidad o la pantalla exhiba un comportamiento err tico puede desear restablecer el...

Страница 25: ...h Consulte Obtenci n de filtros de reemplazo p gina 30 si necesita ayuda para hallar filtros de reemplazo Para cambiar el pre filtro y restablecer el contador de pre filtro 1 Primero apague y desconec...

Страница 26: ...luego hacia arriba Consulte las Fig 4 y 5 p gina 22 3 Tire suavemente del filtro para retirarlo de la unidad Al retirar el filtro observe las flechas de direcci n impresas en la parte superior del fil...

Страница 27: ...la l mpara UVC despu s de 8000 horas aproximadamente 1 a o de uso o cada vez que reemplace el filtro HEPAtech Para cambiar la l mpara UVC 1 Primero apague y desconecte el purificador de aire 2 Luego...

Страница 28: ...para Luego retire cuidadosamente la l mpara de la unidad Consulte la Fig 13 PUEDE ROMPERSE SI SE CAE DESECHE LA BOMBILLA UVC DE ACUERDO cON LOS C DIGOS LOCALES O ESTATALES YA QUE CONTIENE MERCURIO Fig...

Страница 29: ...l mpara 11 Presione el filtro firmemente dentro del purificador de aire Para evitar da ar el elemento del filtro s lo debe presionar en el bastidor del filtro Consulte la p gina 28 NOTA ESTA UNIDAD N...

Страница 30: ...filtro en la p g 24 Cambio del pre filtro en la p g 24 y cambio del filtro en la p g 4 La unidad ha reducido el lujo de aire o aumentado el ruido El filtro est obstruido y debe remplazarse Consulte Ca...

Страница 31: ...L MATERIAL DEL FILTRO O EL FILTRO DE CARB N ESTAGARANT ASUSTITUYEA TODAS LAS OTRAS GARANT AS EXPRESAS LADURACI N DE TODA GARANT A IMPL CITA INCLUYENDO PERO SIN LIMITARSE A CUALQUIER GARANT A IMPL CITA...

Страница 32: ...CESORIOS EN EXCESO DELPRECIO DE COMPRA DEL PURIFICADOR DE AIRE SU NICO RECURSO SER LA REPARACI N O EL REEMPLAZO COMO SE ESTIPUL ANTERIORMENTE ALGUNOS ESTADOS NORTEAMERICANOS Y ALGUNAS PROVINCIAS CANAD...

Отзывы: