8-12. Align the keyhole slots in the upper switch housing with the
housing assembly screws installed in Step 8-8.
8-13. Turn the lower switch housing clockwise until the housing as-
sembly screws installed in sub-steps 1 and 2 are firmly situated
in the narrow end of the keyhole slots. Tighten all four screws
firmly.
8-14. Partially install two of the screws into the lower switch housing
to mount the globe assembly.
8-15. Install candelabra-based light bulb(s), 40 Watt maximum.
8-16. Align the keyhole slots in the light kit with the screws installed
in the lower switch housing.
8-17. Turn the light kit clockwise until the screws installed are firmly
situated in the narrow end of the keyhole slots. Securely install
the third screw and tighten all screws.
CAUTION:
Make sure the lower switch housing/light
assembly is securely attached to the switch housing mounting
plate. Failure to properly attach and tighten all four housing
assembly screws could result in the switch housing and light
fixture falling.