Install&User Manual
38
- Standard wire : Pie off the wiring cover 8~10mm and solder it. Wire gage should
AWG 22~26.
- Sold wire : Peel off the wiring cover 8~10mm and solder it.Wire gage should be AWG 20~26
2.3.2
Inserting & removing wire
To insert & remove wire in Terminal Block, use a screwdriver in the diagram to the below;
2.3.3
Connecting and configuring sensor
2.3.3.1
Specification
In order to run sensor input DVR normally, the following conditions are required.
Spec
Input Ch
Transistor input
HVRM-T1600M. HVRM-T1600Q : 16EA,
HVRM-T800M, HVRM-T800Q : 8EA
HVRM-T400M : 4EA
Input type
N.C, N.O supprt
Supported sensor
Dry contact sensor
Way of connecting
Connecting the trimmed wire to terminal block
Performance
Available
input
pulse range
Minimum 500ms
Output current
Typical DC 12mA