![Hunt Electronic HVRM-T1600L Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/hunt-electronic/hvrm-t1600l/hvrm-t1600l_install-and-users-manual_2184348031.webp)
- Standard wire : Pie off the wiring cover 8~10mm and solder it. Wire gage should AWG
22~26.
- Sold wire : Peel off the wiring cover 8~10mm and solder it.Wire gage should be AWG 20~26.
2.3.2 Inserting & removing wire
To insert & remove wire in Terminal Block, use a screw driver in the diagram like below.
2.3.3 Connecting and configuring sensor
2.3.3.1 Specification
In order to run sensor input DVR normally, the following conditions are required.
Spec
Input Ch
16EA Transistor input
Input type
N.C, N.O supprt
Supported sensor
Dry contact sensor
Way of connecting
Connecting the trimmed wire to terminal block
Performance
Available input
pulse range
Minimum 500ms
Output current
Typical DC 12mA