background image

In 

A

UTOMATIC

mode, the 

L

EGEND

1000 S

ERIES

selects the depth

range best suited to keep
recent sonar returns
visible; however, the depth
range can be adjusted to
optimize the display for
viewing the second return.
The display can also be
optimized for maximum
display resolution, making
it possible to distinguish fish very close together or close
to the bottom. 

Optimizing the Depth Range for Sonar Targets

When the image of the bottom does not appear close
to the bottom of the LCD display, the Legend 1000
Series is not fully optimizing the display to show sonar
targets, such as fish, that are very close together. To
enhance the ability of the unit to separate sonar
targets and to optimize the display for maximum
resolution, follow these steps: 

1. Make sure the Legend 1000 Series is operating in

Automatic Mode.

2. Push the 

R

ANGE

knob. An adjustment indicator

appears at the lower right corner of the 

C

HART

W

INDOW

.

3. Turn the 

R

ANGE

knob counterclockwise until the image

of bottom is close to the bottom of the LCD display
but still shows the area of interest.

Note: As the depth of the water increases, the 

L

EGEND

1000 S

ERIES

changes the depth range to keep the bottom on-screen. The

L

EGEND

1000 S

ERIES

uses a depth range to keep the bottom

contour close to the bottom of the display.

To return the depth range to normal viewing, turn the
unit off and back on again using the 

G

AIN

knob. This is

the only way to reset the depth range to normal
viewing.

Optimizing the Depth Range for Second Return

To optimize the depth range for viewing the second
return, follow these steps.

1. Make sure the 

L

EGEND

1000 S

ERIES

is operating in

Automatic.

2. Push the 

R

ANGE

knob. An adjustment indicator

appears at the lower right corner of the 

C

HART

W

INDOW

.

3. Turn the 

R

ANGE

knob clockwise until the second return

is visible on the display. 

4. To return the depth range to normal viewing, rotate

the 

R

ANGE

knob counterclockwise until the depth

range stops updating.

Note: The second return does not appear at many of the deeper
depth ranges. The appearance of the second return depends
on depth of the water, water conditions, bottom hardness and
the gain setting.

The 

L

EGEND

1000 S

ERIES

operates with this offset depth

range until it is returned to the original settings, or the
unit is turned off, after which the unit defaults to
factory settings.

7

USING THE LEGEND 1000 SERIES

MODES OF OPERATION / OPTIMIZING THE DISPLAY

Adjustment Indicator

Optimized Display

Optimized Display showing second return

Содержание Legend 1000

Страница 1: ...Operations Manual Operational instructions for Humminbird Legend 1000 Series including the Legend 1000 1005 1000 Deep and 1005 Deep...

Страница 2: ...nbird com WARNING This device should not be used as a navigational aid to prevent collision grounding boat damage or personal injury When the boat is moving water depth may change too quickly to allow...

Страница 3: ...oom Mode 8 Manual Mode 8 Chart Speed 9 Sonar View 9 Light 9 Contrast 9 RTS Window 9 Surface Clutter 10 White Line 10 Filter 10 Depth Alarm 10 Temp Alarm 11 Fish Alarm 11 Fish Sensitivity 11 Fish ID 11...

Страница 4: ...chirp sounds as the unit turns on If the unit detects that the transducer is connected and is in water the LEGEND 1000 SERIES begins to show sonar information on the display If the transducer is not...

Страница 5: ...L knob again If no adjustments are made after a few seconds the CONTROL PANEL list is removed automatically Range Knob The RANGE knob adjusts the depth ranges used on the display The RANGE knob has sl...

Страница 6: ...ft bottom shows more gray below Structure appears above the bottom as a cluster of lines with varying lengths and gray shades Fish appear as smaller groupings of sonar returns between the bottom and s...

Страница 7: ...e speed and direction over the location where the structure was originally located Thermoclines The LEGEND 1000 SERIES is also capable of showing layers of water having different temperatures These te...

Страница 8: ...adjusted by using the RANGE knob The active CONTROL PANEL consists of three parts the CONTROL PANEL NAME SETTING INDICATOR and SETTING READOUT The CONTROL PANEL NAME indicates the feature the SETTING...

Страница 9: ...depth range to keep the bottom on screen The LEGEND 1000 SERIES uses a depth range to keep the bottom contour close to the bottom of the display To return the depth range to normal viewing turn the un...

Страница 10: ...membered until the LEGEND 1000 SERIES is powered off when the unit defaults to factory settings Manual Mode MANUAL mode turns off automatic bottom tracking leaving control of the depth range to the us...

Страница 11: ...rightness so the display will be visible at night The backlight will then begin to decrease in intensity automatically until it is off in order to save energy Selecting the CONTROL PANEL LIGHT choice...

Страница 12: ...m composition and structure is reduced Selecting a smaller numeric setting narrows the band and shows greater variation in bottom composition Selecting OFF turns the WHITE LINE feature off The WHITE L...

Страница 13: ...settings OFF plus the three different fish symbols shown onscreen see FISH ID The 1000 Deep 1005 Deep can be set to alarm only large fish displayed as a large fish symbol only large and medium fish di...

Страница 14: ...e CONTROL PANELS and for messages See the LEGEND 1005 1005 DEEP Specifications for included languages LANGUAGE setting is retained in memory after the LEGEND 1005 1005 DEEP is turned off The factory s...

Страница 15: ...nit Next inspect the transducer cable from end to end for breaks kinks or cuts in the outer casing of the cable and repair after disconnecting the cable from both the unit and the transducer Also make...

Страница 16: ...15 380mm from the prop 10 The screen does not display a full fish arch Check the running angle of the transducer If the running angle is too great a full fish arch may not appear Reduce the running a...

Страница 17: ...pair Authorization Number for your unit Please have your product model name and serial number available before calling the factory If you contact the factory by e mail please include your product mode...

Страница 18: ...g Frequencies 50 200 kHz Power Output 4000 Watts Peak to Peak 500 Watts RMS Area of Coverage 20 and 74 at 10 dB Power Requirement 10 20 VDC Display 8 level FSTN Grayscale LCD LCD Matrix 160 H x 160 V...

Отзывы: