background image

TROUBLESHOOTING

Repairs

Do not attempt to repair the 

L

EGEND

1000 S

ERIES

yourself.

There are no user-serviceable parts inside, and
special tools and techniques are required for
reassembly to ensure the waterproof integrity of the
housing. Repairs should be performed only by
authorized Techsonic technicians.

Before You Call Customer Support

Many requests for repair received by Techsonic
involve units that do not actually need repair. These
units are returned “no problem found.” If you have a
problem with your 

L

EGEND

1000 S

ERIES

, use the following

troubleshooting guide before calling Customer
Support or sending your unit in for repair. The 

L

EGEND

1000 S

ERIES

contains several tools that can aid in

determining if there is a problem, as well as how to
isolate and repair a problem in many cases.

1. Nothing happens when I turn the unit on.

Check the power cable connection at both ends. Be
sure the cable is connected correctly to a reliable
power source—red lead to positive, black lead to
negative or ground. Ensure the power available at the
mount is between 10 and 20 VDC. If the unit is wired
through a fuse panel, ensure the panel is powered;
accessory fuse panels often are controlled by a
separate switch or by the boat’s ignition switch. A
fuse also can appear to be good when in fact it is not.
Check the fuse with a tester or replace it with a fuse
known to be good.

Check the power connection to the 

L

EGEND

1000 S

ERIES

. It

is possible to force the power cable connector into
the collector plug incorrectly. If the connector is
reversed, the unit will not work. Examine the contacts
on the back of the unit to ensure there is no corrosion. 

Ensure the cables are properly installed into the
collector plug and the collector plug is properly
seated into the 

L

EGEND

1000 S

ERIES

.

2. The unit starts up in Simulator mode.

The 

L

EGEND

1000 S

ERIES

has the ability to detect that a

transducer is connected. If, at power up, a transducer
is not connected, the unit starts up in 

S

IMULATOR

mode. 

Ensure that an appropriate transducer connector is
used and the connector is positioned correctly in the
collector plug. Also, be sure that the collector plug is
fully-seated into the unit. Next, inspect the transducer
cable from end to end for breaks, kinks, or cuts in the
outer casing of the cable, and repair after

disconnecting the cable from both the unit and the
transducer. Also, make sure that the transducer is fully
submerged in water. If the transducer is connected to
the unit through a switch, temporarily connect it
directly to the unit and try again. If none of these
items identifies an obvious problem, the transducer
itself may be at fault. Be sure to include the
transducer if returning the unit for repair.

To override the 

S

IMULATOR

manually, select the 

S

IMULATOR

C

ONTROL

P

ANEL

and turn to 

O

FF

. See Control Panels for

more information.

3. There is no bottom reading visible on the display.

There are several possible causes for this condition. If
the loss of bottom information occurs only at high
boat speeds, the transducer needs to be adjusted. If
the digital depth readout is working but there is no
bottom visible on-screen, it is possible that the depth
range has been adjusted manually to a range lower
than that needed to display the bottom. Also, in very
deep water, it may be necessary to increase the 

G

AIN

setting manually in order to maintain a graphic
depiction of the bottom.

If you are using a transducer switch to connect two
transducers to the 

L

EGEND

1000 S

ERIES

, make sure that the

switch is in the correct position to connect a
transducer, and that the transducer is submerged in
water. (If a trolling motor transducer is selected and
the trolling motor is out of the water, no sonar
information will appear.) 

If none of the above solves the problem, inspect the
transducer cable from end to end for breaks, kinks, or
cuts in the outer casing of the cable, and repair after
disconnecting the cable from both the unit and the
transducer. If the transducer is connected to the unit
through a switch, temporarily connect it directly to the
unit and try again. If none of these items identifies an
obvious problem, the transducer itself may be at fault.
Be sure to include the transducer if returning the unit
for repair.

4. When in very shallow water, I get gaps in the bottom
reading and inconsistent digital depth indications.

The 

L

EGEND

1000 S

ERIES

will work reliably in water 2' (.6m) or

deeper. Remember that the depth is measured from the
transducer, not necessarily from the surface of the water.

13

MAINTENANCE AND WARRANTY

TROUBLESHOOTING

Содержание Legend 1000

Страница 1: ...Operations Manual Operational instructions for Humminbird Legend 1000 Series including the Legend 1000 1005 1000 Deep and 1005 Deep...

Страница 2: ...nbird com WARNING This device should not be used as a navigational aid to prevent collision grounding boat damage or personal injury When the boat is moving water depth may change too quickly to allow...

Страница 3: ...oom Mode 8 Manual Mode 8 Chart Speed 9 Sonar View 9 Light 9 Contrast 9 RTS Window 9 Surface Clutter 10 White Line 10 Filter 10 Depth Alarm 10 Temp Alarm 11 Fish Alarm 11 Fish Sensitivity 11 Fish ID 11...

Страница 4: ...chirp sounds as the unit turns on If the unit detects that the transducer is connected and is in water the LEGEND 1000 SERIES begins to show sonar information on the display If the transducer is not...

Страница 5: ...L knob again If no adjustments are made after a few seconds the CONTROL PANEL list is removed automatically Range Knob The RANGE knob adjusts the depth ranges used on the display The RANGE knob has sl...

Страница 6: ...ft bottom shows more gray below Structure appears above the bottom as a cluster of lines with varying lengths and gray shades Fish appear as smaller groupings of sonar returns between the bottom and s...

Страница 7: ...e speed and direction over the location where the structure was originally located Thermoclines The LEGEND 1000 SERIES is also capable of showing layers of water having different temperatures These te...

Страница 8: ...adjusted by using the RANGE knob The active CONTROL PANEL consists of three parts the CONTROL PANEL NAME SETTING INDICATOR and SETTING READOUT The CONTROL PANEL NAME indicates the feature the SETTING...

Страница 9: ...depth range to keep the bottom on screen The LEGEND 1000 SERIES uses a depth range to keep the bottom contour close to the bottom of the display To return the depth range to normal viewing turn the un...

Страница 10: ...membered until the LEGEND 1000 SERIES is powered off when the unit defaults to factory settings Manual Mode MANUAL mode turns off automatic bottom tracking leaving control of the depth range to the us...

Страница 11: ...rightness so the display will be visible at night The backlight will then begin to decrease in intensity automatically until it is off in order to save energy Selecting the CONTROL PANEL LIGHT choice...

Страница 12: ...m composition and structure is reduced Selecting a smaller numeric setting narrows the band and shows greater variation in bottom composition Selecting OFF turns the WHITE LINE feature off The WHITE L...

Страница 13: ...settings OFF plus the three different fish symbols shown onscreen see FISH ID The 1000 Deep 1005 Deep can be set to alarm only large fish displayed as a large fish symbol only large and medium fish di...

Страница 14: ...e CONTROL PANELS and for messages See the LEGEND 1005 1005 DEEP Specifications for included languages LANGUAGE setting is retained in memory after the LEGEND 1005 1005 DEEP is turned off The factory s...

Страница 15: ...nit Next inspect the transducer cable from end to end for breaks kinks or cuts in the outer casing of the cable and repair after disconnecting the cable from both the unit and the transducer Also make...

Страница 16: ...15 380mm from the prop 10 The screen does not display a full fish arch Check the running angle of the transducer If the running angle is too great a full fish arch may not appear Reduce the running a...

Страница 17: ...pair Authorization Number for your unit Please have your product model name and serial number available before calling the factory If you contact the factory by e mail please include your product mode...

Страница 18: ...g Frequencies 50 200 kHz Power Output 4000 Watts Peak to Peak 500 Watts RMS Area of Coverage 20 and 74 at 10 dB Power Requirement 10 20 VDC Display 8 level FSTN Grayscale LCD LCD Matrix 160 H x 160 V...

Отзывы: