background image

Notice the Fish Alarm indication on the screen. Any fish (or objects not on the bottom) will trigger 
a short fish alarm sound indication. 
 
Step 6 
Press the Auto Sensitivity On/Off button to change to the manual mode. Notice that the word 
AUTO in the lower left corner of the display has gone off. Also, the area below the bottom is no 
longer blacked out. You can now change the sensitivity setting by pressing the manual set and 
_A or * buttons. Notice that the digital bottom reading goes off in the manual mode. Note: In the 
manual mode the depth range will not automatically change. The automatic depth change works 
only in the automatic mode. Push the Auto On/Off button to go back to the automatic mode. 
Step 7 
 
Steps 1 through 6 have verified that your LCR is working properly. You are now ready to increase 
boat speed to test the transducer installation. As you increase boat speed the LCR should give a 
continuous bottom return. With a proper transducer installation your LCR will perform well at high 
speeds. 
 
TROUBLE SHOOTING: If at high speeds the bottom return is not continuous or there are gaps in 
the bottom, then the transducer installation or location is such that air is going under the 
transducer face. Refer back to the transducer mounting procedure for adjustments or for other 
mounting options. 
 
TROUBLE SHOOTING: If at high speed and high sensitivity setting the display begins to blacken, 
then cavitation noise from the propeller is being received by the transducer. The transducer 
should be moved away from the prop or to another location to reduce the cavitation noise. 
 
TROUBLE SHOOTING: If a fault condition is displayed on the screen, turn the unit off and then 
on again. If this does not clear the fault condition the unit should be returned for repair. 
 
 
LEARNING TO USE SCREEN MEMORY 
 
The operation of the LCR Screen Memory was discussed in detail earlier in this manual. By 
following the steps below you will be able to easily learn how to use this unique feature of your 
unit. 
Step 1 
Your LCR has been pre-programmed at the factory with 16 screens. These pre-programmed 
screens will aid in your learning and hopefully let you have some fun, too. 
Press the Mode Select Button to change from the digital depth display (in the lower right corner of 
the screen) to the Memory Display (See Figure 21). If the screen number is not 1, press the 
Memory Select Button (or hold it down) until 1 is displayed. 
Step 2 
To recall screen number 1 simply press the Memory Recall Button. The left side of the screen will 
now display the screen that was pre-programmed at the factory. 
Step 3 
Now let's store a screen into location 1. Press the Store R (right) button. Recall screen 1 by 
pressing the recall button and see that the old pre-programmed screen has been erased and has 
been replaced by the information from the right half of the screen. This screen will remain in 
location 1 until another screen is stored in its place. 
A screen may be stored at any time, but you might find it easiest to stop the display before storing 
a screen. 
A screen does not have to be recalled before storing another screen in its place. For example, to 
store a new screen in location 1, first use the memory select button to go to location 1. Now the 
left side or right side can be stored by pressing the Store L or Store R button. The Recall Button 
does not have to be pressed unless you want to see the stored information before it is erased and 
replaced by the new information. 

Содержание LCR 8000

Страница 1: ......

Страница 2: ...uding aluminum Please carefully consider the following before installing your transducer TRANSDUCER MOUNTING OPTIONS A Transom Mount The Humminbird high speed transducer allows the transducer element...

Страница 3: ...bronz thru hull transducer has a threaded stem which installs through a hole drilled in the boat hull leaving the housing exposed under the boat This type of installation must be used for many boats...

Страница 4: ...use a silicone sealant between the screwhead and bracket in order to prevent leaking See Figure C Step 2 BRACKET INSTALLATION Fiberglass Boats If your boat has a stepped transom located below and und...

Страница 5: ...cally in the three slots found in the bracket It is important to use a silicone sealant between the screwhead and bracket in order to prevent leaking Step 3 TRANSDUCER PIVOT ASSEMBLY Assemble the pivo...

Страница 6: ...the bracket Slide the O ring on to the headed pin and insert it through the two parts Assemble by screwing the x3 8 allen head screw into the end of the pin and tighten See Figure G Step 5 ANGLE ALLIG...

Страница 7: ...h this type installation it is important that the transducer be mounted by someone familiar with the use of two part epoxy adhesives For this reason Techsonic Industries Inc will not be responsible fo...

Страница 8: ...ye of the transducer The bubbles will disappear in a short time or can be removed by rubbing the transducer eye with your fingers while the transducer is in the water 4 If your instrument should fail...

Страница 9: ...Install the mounting knobs and tighten snugly The unit can now be swiveled and tilted to any desired position...

Страница 10: ...cket can also be mounted directly to the dash without the swivel mount however this method is not recommended since the unit cannot be rotated INSTALLING THE CABLES Your LCR comes equipped with Hummin...

Страница 11: ...ole cover after determining the necessary wire length from the hole The power cable has a red lead to the positive post and the black lead to the negative post Install a 1 amp fuse between the red cab...

Страница 12: ...while still viewing the full depth range information on the right The display used on the LCR is a Liquid Crystal Display The material in the display is a liquid that can be aligned such that it eith...

Страница 13: ...d screen memory work in the same way to give you the benefit of split screen comparisons The detailed operation of each of these functions is explained later in this manual TOTAL SCREEN UPDATE What is...

Страница 14: ...pth scale This Total Screen Update feature works when changing to deeper or shallower scales For example suppose you are in the 0 to 120 foot scale but the bottom depth changes quickly to 20 feet When...

Страница 15: ...itch The LCR always comes on in the automatic mode In the automatic mode the unit will find the bottom by varying the sensitivity and selecting the proper depth range for a satisfactory return Also th...

Страница 16: ...nd later want to change it again you can just press either the or V button if no other function light gray button had been pressed since the zoom range button 4 Depth Automatic Mode In the automatic m...

Страница 17: ...to change to the 0 to 60 foot range The depth range can also be changed by only pressing the depth set button Each time this button is pressed the depth range will decrease become shallower Remember t...

Страница 18: ...hen a hard bottom is being read the sensitivity needed to achieve a good return will be less Also in the automatic mode the unit will black out the display beneath the bottom line Manual Mode There ar...

Страница 19: ...region may be selected as 15 feet 30 feet or 60 feet pressing the range size button Each time this range size button is pressed the zoom range size increases until it is at the maximum then the size...

Страница 20: ...r you have passed over it Remember that because of the LCR s Total Screen Update feature even while you are using Zoom no information is being lost You can turn Zoom off go to any depth range and see...

Страница 21: ...me a return is detected between the boat and the bottom It will not alarm on the bottom but only on objects off the bottom To activate the Fish Alarm press the Fish On Off button The indicator in the...

Страница 22: ...at the previous setting 11 Mode This button selects what is shown in the lower right corner of the display either depth surface temperature or memory location Depth When the LCR is turned on the digit...

Страница 23: ...matically split to display the screen in memory on the left side and the full depth scale information on the right See Figure 20 NOTE If zoom or bottom lock is on when recalling a memory screen then t...

Страница 24: ...d to avoid scratching the lens Care should be exercised to keep chemicals such as bug repelent ammonia abrasive cleaners or gasoline away from the LCR case and lens As with any electrical instrument d...

Страница 25: ...to deeper water until the bottom return goes off the display The LCR will automatically change to the next deeper depth range Notice that the entire screen is changed to the new depth range This is th...

Страница 26: ...splayed on the screen turn the unit off and then on again If this does not clear the fault condition the unit should be returned for repair LEARNING TO USE SCREEN MEMORY The operation of the LCR Scree...

Страница 27: ...ion LEARNING TO READ THE DISPLAY The following illustrations show some typical displays with bottom structure and fish returns These should help you in interpreting the information being displayed on...

Страница 28: ...With bottom lock the wreck and fish are clearly displayed on the left side of the screen which shows an expanded view 40 feet up from the bottom screen is from 112 feet to 172 feet...

Страница 29: ...ermocline therefore if you want to see the thermocline go to the manual mode and increase the sensitivity level OPTIONAL SURFACE TEMPERATURE GAUGE Your LCR 8000 or LCR 8000D is designed to work with a...

Страница 30: ...lay the reading on the LCR screen The probe and computer controlled electronics have been designed for an accurate indication and an extremely fast response time If you do not have a surface temperatu...

Отзывы:

Похожие инструкции для LCR 8000