background image

 

If Display speed or sensitivity is pressed a chirping sound will indicate an incorrect entry. 
When the Stop/Resume button is pressed again the unit will resume reading at the 
immediate point at which the boat is sitting in the water. 

 

6.  Display Speed Set: The LCR has 8 display speed settings. 
 

When the unit is turned on the display will be advancing at a medium speed. To increase 
the display speed, depress the Speed Set and or hold it down to change rapidly. An 
audible sound is heard each time the speed is advanced. When the limit has been 
reached a chirping sound will be heard. At this point the speed will be advancing at its 
maximum. To decrease the speed, simply depress the Speed Set and * until the desired 
advance is reached. 

 

It is suggested that you experiment with various display speeds until you achieve the 
desired results. You should select the fastest display speed for high speed operation, but 
use a slower display speed for idle or trolling speed. 

 

7.  Sensitivity: Automatic Mode: - Each time the unit is turned on, the automatic feature is on. 

In the automatic mode the sensitivity is adjusted automatically to give a good return and 
the correct depth range is selected. The word Auto will appear in the lower left corner of 
the display. The sensitivity bar at the bottom of the screen will increase or decrease 
automatically indicating the amount of sensitivity being used. In deeper water or soft 
bottom conditions this bar will increase indicating more senistivity. In shallow water or 
when a hard bottom is being read, the sensitivity needed to achieve a good return will be 
less. Also in the automatic mode, the unit will black out the display beneath the bottom 
line. 

 

Manual Mode: - There are two ways of putting the LCR in the manual mode; (1) Depress 
the Auto On/Off button or (2) Depress the Manual Set button and then either the 
decrease or _• increase button. There are 15 sensitivity settings. When the * or • or 
button is pressed once, the sensitivity setting at the bottom of the screen will change by 
one division. If the • or A button is held down the setting will move up or down as long as 
the button is held down. When the maximum or minimum setting is achieved, the unit will 
make a "Chirping" sound indicating a limit has been reached. 
 
Also, the word "max" will appear when the maximum sensitivity setting is reached. 

 

In the manual mode everything below the bottom is no longer blacked out, therefore a 
second return or double echo can be displayed if desired. (See Figure 17). Also, the 
hardness of the bottom can sometimes be determined by the thickness of the bottom 
return. For example, a hard or rock bottom will give a wider bottom return as compared to 
a soft or muddy bottom. 

 

Manual Mode 

 

In manual mode everything below the bottom is not blacked out, so that the second 
bottom echo can be seen. 

 

Note: You will find the manual sensitivity control most useful when looking for smaller 
targets such as smaller fish. In the automatic mode the computer might not be using 
enough sensitivity to show smaller targets. At higher sensitivity settings more targets will 
be seen. Therefore, you might want to use the automatic mode while running and then 
use the manual mode for charting and finding fish. 

 

Содержание LCR 8000

Страница 1: ......

Страница 2: ...uding aluminum Please carefully consider the following before installing your transducer TRANSDUCER MOUNTING OPTIONS A Transom Mount The Humminbird high speed transducer allows the transducer element...

Страница 3: ...bronz thru hull transducer has a threaded stem which installs through a hole drilled in the boat hull leaving the housing exposed under the boat This type of installation must be used for many boats...

Страница 4: ...use a silicone sealant between the screwhead and bracket in order to prevent leaking See Figure C Step 2 BRACKET INSTALLATION Fiberglass Boats If your boat has a stepped transom located below and und...

Страница 5: ...cally in the three slots found in the bracket It is important to use a silicone sealant between the screwhead and bracket in order to prevent leaking Step 3 TRANSDUCER PIVOT ASSEMBLY Assemble the pivo...

Страница 6: ...the bracket Slide the O ring on to the headed pin and insert it through the two parts Assemble by screwing the x3 8 allen head screw into the end of the pin and tighten See Figure G Step 5 ANGLE ALLIG...

Страница 7: ...h this type installation it is important that the transducer be mounted by someone familiar with the use of two part epoxy adhesives For this reason Techsonic Industries Inc will not be responsible fo...

Страница 8: ...ye of the transducer The bubbles will disappear in a short time or can be removed by rubbing the transducer eye with your fingers while the transducer is in the water 4 If your instrument should fail...

Страница 9: ...Install the mounting knobs and tighten snugly The unit can now be swiveled and tilted to any desired position...

Страница 10: ...cket can also be mounted directly to the dash without the swivel mount however this method is not recommended since the unit cannot be rotated INSTALLING THE CABLES Your LCR comes equipped with Hummin...

Страница 11: ...ole cover after determining the necessary wire length from the hole The power cable has a red lead to the positive post and the black lead to the negative post Install a 1 amp fuse between the red cab...

Страница 12: ...while still viewing the full depth range information on the right The display used on the LCR is a Liquid Crystal Display The material in the display is a liquid that can be aligned such that it eith...

Страница 13: ...d screen memory work in the same way to give you the benefit of split screen comparisons The detailed operation of each of these functions is explained later in this manual TOTAL SCREEN UPDATE What is...

Страница 14: ...pth scale This Total Screen Update feature works when changing to deeper or shallower scales For example suppose you are in the 0 to 120 foot scale but the bottom depth changes quickly to 20 feet When...

Страница 15: ...itch The LCR always comes on in the automatic mode In the automatic mode the unit will find the bottom by varying the sensitivity and selecting the proper depth range for a satisfactory return Also th...

Страница 16: ...nd later want to change it again you can just press either the or V button if no other function light gray button had been pressed since the zoom range button 4 Depth Automatic Mode In the automatic m...

Страница 17: ...to change to the 0 to 60 foot range The depth range can also be changed by only pressing the depth set button Each time this button is pressed the depth range will decrease become shallower Remember t...

Страница 18: ...hen a hard bottom is being read the sensitivity needed to achieve a good return will be less Also in the automatic mode the unit will black out the display beneath the bottom line Manual Mode There ar...

Страница 19: ...region may be selected as 15 feet 30 feet or 60 feet pressing the range size button Each time this range size button is pressed the zoom range size increases until it is at the maximum then the size...

Страница 20: ...r you have passed over it Remember that because of the LCR s Total Screen Update feature even while you are using Zoom no information is being lost You can turn Zoom off go to any depth range and see...

Страница 21: ...me a return is detected between the boat and the bottom It will not alarm on the bottom but only on objects off the bottom To activate the Fish Alarm press the Fish On Off button The indicator in the...

Страница 22: ...at the previous setting 11 Mode This button selects what is shown in the lower right corner of the display either depth surface temperature or memory location Depth When the LCR is turned on the digit...

Страница 23: ...matically split to display the screen in memory on the left side and the full depth scale information on the right See Figure 20 NOTE If zoom or bottom lock is on when recalling a memory screen then t...

Страница 24: ...d to avoid scratching the lens Care should be exercised to keep chemicals such as bug repelent ammonia abrasive cleaners or gasoline away from the LCR case and lens As with any electrical instrument d...

Страница 25: ...to deeper water until the bottom return goes off the display The LCR will automatically change to the next deeper depth range Notice that the entire screen is changed to the new depth range This is th...

Страница 26: ...splayed on the screen turn the unit off and then on again If this does not clear the fault condition the unit should be returned for repair LEARNING TO USE SCREEN MEMORY The operation of the LCR Scree...

Страница 27: ...ion LEARNING TO READ THE DISPLAY The following illustrations show some typical displays with bottom structure and fish returns These should help you in interpreting the information being displayed on...

Страница 28: ...With bottom lock the wreck and fish are clearly displayed on the left side of the screen which shows an expanded view 40 feet up from the bottom screen is from 112 feet to 172 feet...

Страница 29: ...ermocline therefore if you want to see the thermocline go to the manual mode and increase the sensitivity level OPTIONAL SURFACE TEMPERATURE GAUGE Your LCR 8000 or LCR 8000D is designed to work with a...

Страница 30: ...lay the reading on the LCR screen The probe and computer controlled electronics have been designed for an accurate indication and an extremely fast response time If you do not have a surface temperatu...

Отзывы:

Похожие инструкции для LCR 8000