Connect Power
Use the following instructions to connect power to the scanner unit. Also, see the illustration and table for
more information.
1.
Route the cable to the fuse panel or battery (12V to 20 VDC required). Make sure that the Data
connector can also reach the control head.
2.
Connect the Large Black wire to the negative (-) terminal of the fuse panel or battery.
3.
Connect the Large White wire (with the in-line fuse) to the positive (+) terminal of the fuse panel
or battery.
NOTE:
Do not remove the in-line fuse unless a dedicated and fused terminal is available. If so, install a 5A
fuse (AS 12RD2KW) or an 8 Amp fuse (AS 21RD4KW).
4.
The green and blue wires must connect to enable radar (open = disabled, closed = enabled).
The installation options are as follows:
To connect the scanner to an On/Off switch or relay:
Connect the small green wire to the
normally closed lead and the small blue wire to the normally open lead.
If you are not connecting the scanner to an On/Off switch or relay,
connect the wires
together.
NOTE:
The On/Off Switch or relay is optional. Please contact our Customer Resource Center for more
information.
NOTE:
The On/Off control switch or relay provides a signal that controls the DC power inside the scanner
unit. It does not switch the main power leads to the scanner unit.
5.
Plug the Data Connector into the adapter cable.
6.
Connect the adapter cable to the control head's Ethernet port. Hand-tighten the screw nut.
7.
Proceed to Radar Configuration.
12
Installation
Humminbird_Radar_Manual_531986-1EN_A.qxp:Layout 1 9/19/11 4:37 PM Page 12