Safety Notices

1. When moving humidifier, lift up the base and 
water tank together. Do not only lift water tank.

2. Do not press the electric cord with heavy 
objects in order to present electric shock of  
fire hazards.

3. Do not use damaged plug or electric cord  
in order to prevent fire hazards.

4. Do not replace electric cord by yourself. If it is 
damaged, please contact with our repair center 
or other qualified technicians to replace it.

5. Do not unplug with wet hands in order to 
prevent electric shock of fire hazards. Shut 
down humidifier before detaching the water 
tank.

6. Do not move humidifier when it is operating. 
If the base is not positioned on a flat and level 
surface, shut down humidifier and adjust its 
position.

7. To prevent explosion or fire hazards, do not 
place humidifier near flammable articles.

8. Do not place clothing or towels on top of 
humidifier. If the mist nozzle is covered or 
blocked, it may cause malfunction.

9. Do not place substances such as metal, 
chemicals or detergent into the reservoir, since 
this will cause poor atomization.

10. Do not operate humidifier when there is no 
water inside the water tank. Do not touch water 
in the reservoir during operation.

11. Use power voltage and frequency in 
accordance with the technical specifications. 
Connect power plug properly in order to prevent 
fire hazards.

12. Contact our company to purchase a new 
aroma diffuser when necessary.

Содержание TALL BBH-50

Страница 1: ...1 Product Manual Ultrasonic Humidifier TALL ...

Страница 2: ...2 ...

Страница 3: ...rt Description Features Specifications Instructions Cleaning Safety Notices Troubleshooting After sales Service 04 05 06 12 13 14 15 Use Set the Mist Volume Set the Timer Use the Remote Controller Contents ...

Страница 4: ...iption Indicator Light Main Body Water Tank Cap Water Tank Water Tank Handle Remote Controller Tank Outer Cover Mist Nozzle Air Filter Signal Receiving Point Power Button Power Button Remote Controller Timer Button ...

Страница 5: ... Specifications Product Name Function Model Number Rated Voltage Max Output Water Tank Capacity Rated Power Rated Frequency TALL Ultrasonic Humidifier BBH 50 100 120 V 300 mL h 2 8 L 23 W 50 60 Hz Washable Timer ...

Страница 6: ... flat hard surface Do not place on carpet rugs Lift off the tank outer cover detach the tank and hold it upside down Undo the tank cap and fill with clean water Replace the cap and close it tightly Attach the tank back to the base properly Connect to the power supply 100 120V 50 60Hz Press the power button indicator light is on and humidifier starts to operate Instructions ...

Страница 7: ...t will change colors depending on which level is selected 1 7 Set the Mist Volume Indicator light light up Orange Green Blue Red Off Mist Level Low Medium High Sleep Mode 5 hours preset Shut off Press Power Button First press Second Press Third Press Forth Press Fifth Press ...

Страница 8: ...e Close the tank cap tightly after refilling in order to prevent leakage The tank must be kept clean if there is any dirt on the atomizer clean it off gently with a small brush 8 Under low medium or high mist level press power button for 3 seconds to set the 2 hour timer for the selected mist level To cancel the timer Press and hold the power button for 3 seconds After continuous of 10 hrs use all...

Страница 9: ...ng ways Indicator light will change colors and a beep is heard Use the Remote Controller 1 Indicator light light up Orange Green Blue Red Off Mist Level Low Medium Strong Sleep Mode 5 hours preset Shut off Press Power Button First press Second Press Third Press Forth Press Fifth Press ...

Страница 10: ...hat timer has been set Low Medium Strong mode is 2 hours Press timer button again to cancel it Sleep mode is 5 hours timer default no need any set Press timer button Orange Low 2 Hours Press timer button Green Middle 2 Hours Press timer button Blue Strong 2 Hours Operation Light indicator Mist level Set timer light flashing 2 ...

Страница 11: ...11 To place and take out the remote control push inside for placement push again for taking out 1 Remote control connector is directed at body ...

Страница 12: ...in the base surface with the brush and rinse it with clean water Clean the reservoir once every week If there is any scale wipe away with a soft cloth and rinse it with clean water Clean the reservoir once every week If there is any scale wipe away with a soft cloth and rinse it with clean water Tank Cleaning Atomizer Cleaning Reservoir Cleaning Surface Cleaning Cleaning Power plug must be disconn...

Страница 13: ... when it is operating If the base is not positioned on a flat and level surface shut down humidifier and adjust its position 7 To prevent explosion or fire hazards do not place humidifier near flammable articles 8 Do not place clothing or towels on top of humidifier If the mist nozzle is covered or blocked it may cause malfunction 9 Do not place substances such as metal chemicals or detergent into...

Страница 14: ...mizer and refill water tank with clean water 1 Adjust the water level make sure cap is screwed on correctly the release valve spring is functioning Ensure that the dots on base tank line up 1 Attach water tank to base properly making sure tank base are aligned Fault Press power button but indicator light does not light up Indicator light is on and wind blows but there is no mist released Mist has ...

Страница 15: ...r soften filter it is recommended to replace every 2 months according to the regional water quality conditions in order to ensure the water soften effect 5 Ensure that the product is placed in a horizontal plane otherwise it may affect the mist output or cause water leakage 6 Please avoid water flowing into the main unit from the air outlet If the product is dumped accidentally and the main unit i...

Страница 16: ...16 ...

Отзывы: