background image

IMPORTANT SAFETY INSTRUCTIONS 

RISK OF EXPLOSION OR FIRE

WHAT CAN HAPPEN

It is normal for electrical contacts within the motor and pressure

switch to spark.

If electrical sparks from the compressor come in contact with

flammable vapors, they may ignite, causing fire or explosion.

Restricting any of the compressor ventilation openings will

cause serious overheating and could cause a fire.

Unattended operation of this compressor could result in

personal injury or property damage.

HOW TO PREVENT

Always operate the compressor in a well ventilated area free of

combustible materials, gasoline or solvent vapors. If spraying

flammable materials, locate the compressor at least 20 feet

away from the spray area. An additional length of hose may be

required.

Store flammable materials in a secure location away from the

compressor.

Never place objects against or on top of the compressor.

Operate compressor in an open area at least 12 inches away

from any wall or obstruction that would restrict the flow or fresh

air to the ventilation openings.

Operate compressor in a clean, dry and well ventilated area.

Do not operate compressor indoors in a confined area.

Always remain in attendance with the compressor when it is

operating.

RISK OF BURSTING

WHAT CAN HAPPEN

1. Failure to properly drain condensed water from the tank,

causing rust and thinning of the steel tank.

2. Modifications or attempted repairs to the tank.

3. Unauthorized modifications to the unloader valve, safety

valve or any other components which control tank pressure.

4. Excessive vibration can weaken the air tank and cause

rupture or explosion.

5.  Attachments & Accessories; Exceeding the operating

pressure of air tools can cause them to explode.

HOW TO PREVENT

Drain tank daily or after every use. If the tank develops a leak,

replace tank or get a new air compressor. Never drill into, weld

or make any modifications to the tank or its attachments.

The tank is designed to withstand specific operating pressures.

Never make adjustments or parts substitutions to alter the

factory set operating pressures.

For essential control of air pressure, you must install a

pressure regulator and pressure gauge to the air outlet.

RISK OF BURNS

WHAT CAN HAPPEN

Touching exposed metal such as the compressor head or

outlet tubes, can result in serious burns.

HOW TO PREVENT

Never touch any exposed metal parts on compressor during or

immediately after operation. The compressor will remain hot

several minutes after use.

Do not reach around protective shrouds or attempt

maintenance until the compressor has cooled down

completely.

RISK OF PROPERTY DAMAGE WHEN
TRANSPORTING COMPRESSOR

WHAT CAN HAPPEN

Oil can leak or spill and could result in fire or breathing hazard,

serious injury or death can result. Oil leaks will damage carpet,

paint or other surfaces in vehicules or trailers.

HOW TO PREVENT

Always place compressor on a protective mat when

transporting to protect against damage to vehicle from leaks.

Remove compressor from vehicles immediately apon arrival.

3

Содержание HP02P005S1

Страница 1: ......

Страница 2: ...OMPRESSOR DOES NOT SUPPLY BREATHABLE AIR RISK OF BURSTING DO NOT ADJUST REGULATOR TO RESULT IN OUTPUT PRESSURE GREATER THAN MARKED MAXIMUM PRESSURE OF ATTACHMENT IF A REGULATOR HAS NOT BEEN INSTALLED...

Страница 3: ...K makes every effort to ensure that this product meets high quality and durability standards HULK warrants to the original retail consumer a 2 year limited warranty as of the date the product was purc...

Страница 4: ...tank 3 Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure 4 Excessive vibration can weaken the air tank and cause rupture or explosion 5...

Страница 5: ...local codes and ordinances WARNING TO MAINTAIN PROPER GROUNDING DO NOT REMOVE OR ALTER THE GROUNDING PRONG IN ANY MANNER 110V OPERATION As received from the factory your compressor is ready to run fo...

Страница 6: ...gulator and is always less than or equal to the tank pressure TANK PRESSURE GAUGE A FIG 6 The tank pressure gauge indicates the reserve air pressure in the tank COOLING SYSTEM This compressor contains...

Страница 7: ...maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating of the tool being used 3 Turn the ON AUTO OFF lever to ON AUTO and al...

Страница 8: ...t be drained from the crank case by unscrewing and removing oil sight glass C Fig 8 Drain oil and replace oil sight glass To fill the crank case with oil first unscrew and remove oil breather cap A po...

Страница 9: ...PARTS DIAGRAM MODEL HP02P005S1 8...

Страница 10: ...30602001 BB30701003 AR10103200 BB30701001 FC10103201 WW30505000 RM00403001 SW30502052 HB30205192 FA40702000 SR30504140 CA40801070 MC50102000 No Part Number Description Qty FB30305012 FB30305022 MB2020...

Страница 11: ...937 540 1157...

Отзывы: