Chapter 3---Service Adjustments
To perform software upgrade:
1. Verify that the projector circuit breaker is off. Use a Null Modem
cable to connect a PC to the projector’s Serial Port A.
2. Start Windows 3.1.
3. Click on the terminal icon from the Accessories Directory.
4. From the Terminal menu, select Settings-Terminal Emulation
and click on DEC-VT-100(ANSI).
Select OK.
5. Under Settings choose Terminal Preferences.
6. Under Terminal Preferences the following selections are
appropriate; Terminal Modes=Sound, CR->CR/LF=Both off,
Columns=80, Cursor=Block & Blink, Terminal Font=Fixedsys
15, Translation=None, Show Scroll Bars=On, Buffer Lines=100,
Use Function Arrow & Control Keys for Windows=Off. Select
OK.
7. Under Settings select Text Transfer=Standard Flow Control.
Select OK.
8. Under Settings select Communications and choose;
Connector=select the PC port being used, Baud Rate=9600 or
19200 (depending on the System Controller Switch block Pos
4-see note below this step), Data Bits=8, Stop Bits=1,
Parity=None, Parity Check=Off, Carrier Detect=Off, Flow
Control=XON/XOFF. Select OK.
NOTE:
Switch position 4 on the switch block at the card edge of
the System Controller (
see Figure 5-1
) controls the baud rate
for Serial Port A for the Boot Manager and System Software.
Down=9600, Up=19200. Ensure the other SCB switches (1, 2,
and 3) are in the Down position.
9. Turn the projector circuit breaker on while depressing and
holding down the service mode switch on the SCB (
see Figure
5-1)
for at least 5 seconds or until "Boot Manager" appears on
the terminal monitor. The Power On LED stays Red.
10. The following should be displayed on the Windows Terminal
screen (where x.x.0 is the currently loaded Boot Manager
version (e.g. 0.9.0 or 1.1.0).
–Boot Manager Ver x.x.0 (Service Mode Startup)
–Copyright (c) 1994 Hughes JVC Technology
–Command:
_
11. Verify that the Boot Manager version is correct. If it is
necessary to update the Boot Manager, perform the following
steps. If the Boot Manager is already up to date, skip to Step 12
to update the System Software.
11A. Enter the command "loadboot" at the prompt. You should
see the following output:
Model 220 Service Manual
3-15
Содержание 220
Страница 1: ...SERVICE MANUAL Model 220 Projector ...
Страница 10: ...Safety Information Model 220 Service Manual x ...
Страница 14: ...Chapter 1 Introduction 1 4 Model 220 Service Manual ...
Страница 20: ...Chapter 2 System Description Figure 2 1 Optical System Block Diagram 2 6 Model 220 Service Manual ...
Страница 119: ...Chapter 4 Maintenance Removal Replacement 4 26 Model 220 Service Manual ...
Страница 129: ...Chapter 5 Troubleshooting 5 10 Model 220 Service Manual ...
Страница 140: ...Glossary Model 220 Service Manual B 5 ...