Chapter 4---Maintenance (Removal/Replacement)
Figure 4-6
High Voltage Power Supply.
3. Carefully slide the cover upward and outward to
remove it.
NOTE:
For the remainder of this procedure refer to Figure
4-6 above.
4. Disconnect the 3 CRT anode cables.
5. Disconnect P44-G2 Out (at the middle-front of the
HVPS).
6. Unsnap the cable clamp at the top of the HVPS.
7. Remove the anode cables and the P44 cable from the
cable clamp.
8. Disconnect P45 (“Control”) at upper left of HVPS.
9. Disconnect and label the 3 Focus cables. The square
tabs on these cables (see Figure 4-6) may have to be
lifted up by gently prying with a flathead screwdriver.
10. Remove all cables from the slot in the cable guide at
the left side of the HVPS.
11. Verify that all plugs and cables are removed and out of
the way so the HVPS is free to be removed.
12. Loosen (do not remove) the 2 pozidrive screws (at the
bottom of the HVPS) that secure the HVPS metal
housing to the projector.
13. Remove the 2 pozidrive screws that hold the top of the
HVPS metal housing to the projector frame.