5.  HEALTH & SAFETY   

5.1 

OPERATION & MAINTENANCE 

General  
This equipment/machinery is designed and constructed for industrial use only for the suppression of 
dust and similar in controlled environments with limited access, for example fenced 
construction/demolition sites. 
It should only be used by persons trained and competent in its operation in accordance with the 
instructions within this manual, and should only be maintained / repaired by persons trained and 
competent to do so, following the isolation and making safe of the equipment as detailed within this 
manual. 
The machine must not be misused in any way, nor any hazardous areas accessed, for example 
inside the oscillating mechanism during operation. 
The machine should only be used in a safe location away from other persons not involved in the 
demolition activity and a safe working area should be established with other persons kept away. 
The machine should not be left unattended where there is the possibility of access or operation by 
unauthorised persons.  
 Safety in Operation 

  This equipment/machinery is designed and constructed for industrial use only for the 

suppression of dust and similar in controlled environments with limited access, for example 
fenced construction/demolition sites. 

  It should only be used by persons trained and competent in its operation in accordance with 

the instructions within this manual, and should only be maintained / repaired by persons 
trained and competent to do so, following the isolation and making safe of the equipment as 
detailed within this manual. 

  The machine must not be misused in any way, nor any hazardous areas accessed, for 

example inside the oscillating mechanism during operation. 

  The spray head must never be directed at any person or animal. 

  The machine should only be used in a safe location away from other persons not involved in 

the demolition activity and a safe working area should be established with other persons kept 
away, and monitored on a continuous basis. 

  The machine should not be left unattended where there is the possibility of access or 

operation by unauthorised persons. No guards or other safety features may be disabled or 
bypassed, nor may they be removed unless for authorised maintenance or repair, again 
following the correct isolation procedures. 

  The operator must not access, or allow access by others to any hazard area during operation, 

and all other persons must be kept away from these areas, notably: 

o

  From around the machine 

o

  From the area in which the spray is directed 

Safety features and regular checking 
Safety features are provided for the protection of all and their effectiveness must be verified and 
recorded on a daily basis as follows: 

  Oscillating mechanism enclosure/guard be in place, undamaged and effective. 

  Correct operation of oscillation Off/On selector and HP water isolation valve. 

  Safety signage in place and legible. 

Isolation for intervention, maintenance and repair 

  Before accessing any parts of the machine/equipment for purposes of maintenance or repair, 

make safe and isolate energy sources as follows (and in accordance with the user’s 
procedures): 

o

  Ensure the Commando unit is stopped and take precautions to prevent it from being 

started. 

o

  Ensure that the HP water is depressurised. 

Содержание COMMANDO DUSTGUARD

Страница 1: ...ny purpose other than to assist in the safe operation and maintenance of the Dustguard Water Spray Unit without the express permission of Hugh Crane Cleaning Equipment Ltd For Sales Service and Spare Parts contact HUGH CRANE Cleaning Equipment Ltd www hughcrane co uk TEL 01493 750072 FAX 01493 751854 Email sales hughcrane co uk FS09628 HUGH CRANE Cleaning Equipment Limited SOUTH WALSHAM ROAD ACLE ...

Страница 2: ...anufacture 2 Machinery Designation 3 General Description 4 EC Declaration of Conformity and Warranty 5 Health Safety 5 1 Operation maintenance 5 2 Inspection testing before use 6 Legionella Legionnaire s Disease 7 Noise 8 Operating Instructions 8 1 General 8 2 Machine Operation 8 3 Operator Controls 8 4 Locating Starting the unit 8 5 Frost protection 9 Maintenance Servicing 9 1 General Safety 9 2 ...

Страница 3: ...erator to obtain the best from the equipment via correct operating and maintenance procedures together with basic safety points The Dustguard unit is designed to easily bolt on to a standard Hugh Crane 500D Electric Start pressure washer and can be supplied either as an attachment for the customer to fit or as a complete unit already attached to the 500D washer To power the oscillation device elec...

Страница 4: ...te of purchase guarantees are not transferable subject to good use and adherence to recommended service procedures Major components are subject to individual manufacturer s warranty conditions Wearing parts including tyres pump seals valves hoses filters jets and tooling are excluded from warranty cover unless subject to faulty materials or manufacture ...

Страница 5: ...quipment as detailed within this manual The machine must not be misused in any way nor any hazardous areas accessed for example inside the oscillating mechanism during operation The spray head must never be directed at any person or animal The machine should only be used in a safe location away from other persons not involved in the demolition activity and a safe working area should be established...

Страница 6: ...ppropriate precautions being put in place by the user Legionellosis Legionella bacteria can be present and breed in water at temperatures between 20 and 45C and can thrive in the presence of nutrients such as rust sludge scale algae organic material or other bacteria The equipment should therefore be operated outside these temperatures and regularly cleaned flushed and maintained to prevent the de...

Страница 7: ...ith the engine stopped locate the machine in the required position on site Ensure the valve controlling the HP water to the spray unit is OFF the oscillation is OFF and the oscillation stroke set to minimum Set the spray elevation and stroke to meet anticipated requirements Ensuring yourself and others are well clear of the spray zone start the Commando unit Once up to pressure and ensuring the sp...

Страница 8: ...e not only likely to be a source of rupture but may also cause severe cuts Of particular relevance are the end fittings of hoses which can be subjected to stress caused by pulling at sharp angles or stretching Hoses must be inspected regularly Where quick release couplings are employed they should be inspected regularly for wear damage and for condition of any sealing rings 5 2 3 Guarding The mach...

Страница 9: ...e exposed and any precautions necessary 8 OPERATING INSTRUCTIONS 8 1 GENERAL 8 1 1 Before putting the Dustguard unit into operation it is vital to risk assess the task and environment and formulate a plan Safe System of Work which ensures protection of all persons who could potentially enter the area of operation including operators Any persons or properties directly affected by the spraying shoul...

Страница 10: ...difications or changes to the specification of this machine should be made without consultation with and approval of the manufacturer e The machine is supplied with guarding in compliance with current legislation The machine should not be operated with any of the guards covers or any other safety equipment removed or damaged f Chemicals may be used in conjunction with this equipment Only chemicals...

Страница 11: ...oscillation action The latter determines the length angle of the stroke and thus the extent of the spray area either a Long L Medium M or Short S stroke In addition a valve is provided where the oscillation water supply is connected to the HP pressure washer outlet which allows the water supply to the oscillation unit to be turned on and off Adjustments should only be made to the oscillation unit ...

Страница 12: ...black knob securing the elevation angle is tight Ensuring yourself and others are well clear of the spray zone start the Commando unit Once up to pressure and ensuring the spray zone remains clear of people gently open the HP water valve and when fully open check that the spray is going where required Any further adjustment of the spray elevation angle or stroke should only take place with the HP ...

Страница 13: ...pment employed After use it is essential that all equipment is clean and prepared for the next usage Particular attention should be paid to clean hoses and assemblies jets couplings exposed threads and any such associated tooling WARNING NEVER ATTEMPT TO ADJUST OR CLEAN ANY PART OF THE MACHINE WITH THE ENGINE RUNNING 9 2 MAINTENANCE The unit is designed to require minimal maintenance and there are...

Отзывы: