PRINCIPLE OF PUMP OPERATION
The diaphragm pump is consisted of two diaphragm chambers and
two diaphragms.The diaphragms are connected to each other with a
diaphragm rod andmove in a reciprocating action.As one diaphragm
performs thedischarge stroke, the other diaphragm which is
connected with the rod ispulled to perform the suction.At the end of
the stroke, an airdistribution valve automatically shifts, reversing the
entire sequence, filling and pumping from alternate chambers. Mutual
movements that repeatedcontinuouslyensure suction and discharge
movements onto the fluids in each chamber.Continuously repeated
reciprocal motions pump the liquid during entering to andexitingfrom
the chambers.The flow of the fluid from one chamber to another is
regulated by the suction and discharge valves.
The ball and butterfly valves automatically controls the fluid suction
and discharge of the fluid.The butterfly valves allow passage of the
solid particles with a size up to diameter of the pipe.The ball valves
regulate passage of the small-size particles.