Huck POWERIG 940 Скачать руководство пользователя страница 5

940 series Powerig® 

(HK496)

                        

 

 

 

Alcoa Fastening Systems & Rings

5

CSA CERTIFIED

WIDTH:

 16.1 inches 

(40.9 cm)

LENGTH:

 13.9 inches 

(35.4 cm)

HEIGHT:

 18.5 inches 

(47 cm)

WEIGHT:

 66 pounds 

(30 kg)

 

(with empty reservoir) 

ELECTRICAL SYSTEM:

  

115VAC (25A), 50/60hz, single phase

CONTROL SYSTEM:  

Solenoid operated directional valve, 24V 

MOTOR:  

12000 RPM, 1-1/8 HP, 25 amps. nominal

PUMP:  

2-stage, gear-piston type, 70 in

3

/min @5,000 psi out pres-

sure 

(Output pressure adjustable to 10,000 psi)

RESERVOIR CAPACITY: 

2.6 gallons 

(9.8 liters)

PRESSURE SETTING AS SHIPPED:

      RETURN: 2,200-2,400 psi 

(15,200-16,500 kPa)

      PULL: 5,400 - 5,700psi 

(37,200 - 39,300 kPa)

Minimum Operating Temperature (ambient):

 0° (18°C)

Maximum Hydraulic Fluid Temperature:

 150°F (65°C)

HYDRAULIC FLUID: 

Hydraulic fluid shall meet DEXRON® 

III, DEXRON VI, MERCON, Allison C-4 or equivalent ATF 

specifications. 

Fire resistant fluid may be used if it is an ester based fluid 

such as Quintolubric HFD or equivalent.  Water based fluid 

shall NOT be used as serious damage to equipment will 

occur.

DEXRON is a registered trademark of General Motors Corporation.

s

peCIfICatIons

 









 



  

 

­

€‚

ƒ  

„

 ­

…

†

f

Igure

 1

See Figures 1 & 5. Model 940 POWERIG

®

 Hydraulic Unit 

is a portable, electrically operated power source designed 

to operate all Huck hydraulic installation equipment exclud-

ing Huck-Spin

®

 tools. Model 940 operates on 115 volt AC, 

50-60 Hz, one-phase electrical power. The 

power cord

 is a 

10/3 SJTO cord with a NEMA L5-30 plug. The 

motor

 on the 

Powerig is rated at 115V, 50/60Hertz, 25A.

An 

electrical enclosure

 contains a motor contactor, trans-

former, relay and circuit breaker. Hydraulic pressure is 

developed by a two-stage, gear-piston 

pump

 driven by a 1 

1/8 horsepower universal electric 

motor

. Pressurized fluid is 

directed by a 

four-way directional valve

 to either the PULL 

or RETURN port of the installation equipment. The four-way 

directional valve is operated by a 24 volt AC control circuit. 

The 

high pressure relief valve

 controls  PULL pressure 

(maximum pressure of the unit) and is adjustable by the 

operator. An internal relief valve is preset at the factory to 

protect the Operator and equipment. The internal relief is 

not adjustable by the operator. A 

pressure switch

 controls 

RETURN pressure and turns off the POWERIG Hydraulic 

Unil at the end of an installation cycle. Pressures are adjust-

able to match Huck equipment being used. See applicable 

tool instruction manual for pressure settings for other Huck 

installation equipment.

Hydraulic fluid is stored in the 

reservoir 

which also serves 

as the base. Remove the 

filler cap/dipstick

 to check fluid 

level and to add fluid. 

Hydraulic quick disconnect cou-

plers

 are furnished for connecting hoses from installation 

equipment.

D

esCrIptIon

Main Components

Содержание POWERIG 940

Страница 1: ...August 6 2015 HK496 Instruction Manual Model 940 POWERIG Hydraulic Unit Makers of Huck Marson Recoil Brand Fasteners Tools Accessories ...

Страница 2: ...940 series Powerig HK496 Alcoa Fastening Systems Rings 2 NOTICE This manual applies to 940 serial number 3927 and above For any other serial numbers please contact a Huck customer service representative ...

Страница 3: ...Rings 3 Contents Safety 4 Description 5 Specifications 5 Principle of Operation 6 Preparation for Use 6 Checking and Adjusting Pressures 7 Operation 7 Maintenance 8 Assembly Reference Drawings 9 11 Powerig Options and Accessories 12 Troubleshooting 12 ...

Страница 4: ...ury from fastener ejecting may occur 17 Where applicable always clear spent pintail out of nose assembly before installing the next fastener 18 There is possibility of forcible ejection of pintails or spent mandrels from front of tool 19 Check clearance between trigger and work piece to ensure there is no pinch point when tool is activated Remote triggers are available for hydraulic tooling if pin...

Страница 5: ... exclud ing Huck Spin tools Model 940 operates on 115 volt AC 50 60 Hz one phase electrical power The power cord is a 10 3 SJTO cord with a NEMA L5 30 plug The motor on the Powerig is rated at 115V 50 60Hertz 25A An electrical enclosure contains a motor contactor trans former relay and circuit breaker Hydraulic pressure is developed by a two stage gear piston pump driven by a 1 1 8 horsepower univ...

Страница 6: ...ection al valve spools Pressurized fluid is directed to the RETURN pressure port of the installation equipment The motor contactor is held closed until the preset RETURN pressure is reached and pressure switch PS contacts open The motor turns off the pres sure drops and pressure switch returns to the closed normal position Service Introduction of foreign material into Hydraulic Unit will result in...

Страница 7: ...psi Refer to specific tool instruction manual for PULL and RETURN pressures Severe personal injury may occur if excessive pressures cause violent failure of equipment Higher than normal pres sures will also cause premature wear of equipment WARNING If recommended maximum pressure is exceeded violent failure of fastening system may occur This may cause severe personal injury Operation Before each u...

Страница 8: ...aul is necessary return the directional valve to the nearest repair facility shown on the inside of the back cover Clean components in mineral spirits Smear LUBRIPLATE 130AA or equivalent on O rings and mating surfaces to aid assembly and prevent damage to O rings LUBRIPLATE is trademarked and manu factured by Fiske Brothers Refining Co and is avail able in most localities A handy tube of LUBRIPLA...

Страница 9: ...rig HK496 Alcoa Fastening Systems Rings 9 Note This assembly is purchased complete The bill of material listed is for reference and replacement part purposes only 10 4 with 4 Figure 4 111345 Pump Motor Valve Assembly ...

Страница 10: ...08266 502783 Screw 500693 Lockwasher 500234 Hex Nut 590303 Schematic Sticker 506368 Enclosure Gasket 123479 Enclosure 507293 Transformer 500424 Screw 4 502767 Screw 2 502758 Screw 2 590131 Sticker 115V AC 590131 Sticker Class 2 Circuit 30V 123433 Enclosure Panel 590134 Sticker 24V AC 501214 Screw 3 590012 Nameplate 502992 Screw 4 Motor Cord 502783 Screw 4 Pressure Switch Solenoid 123432 Motor Gask...

Страница 11: ...ire No Color From To 1A red transformer lower right circuit breaker 1 red CR12 CR9 1 red circuit breaker MCL3 1 red MCL1 MCL3 1 red MCL3 CR9 2 white MCL2 transformer lower left 2 white MC terminal MCL2 3 red MCT3 CR5 6 blue transformer upper left trigger 7 blue trigger CR14 8 blue transformer upper right CR13 ...

Страница 12: ...tion slow Entire cycle does occur a Pump is cavitating fluid level may be low or fluid viscosity is too heavy b Strainer is dirty and clogged c Worn or defective directional valve d Worn or damaged pump e Worn or defective hydraulic couplers Always check the simplest possible cause of malfunction first For example blown fuse tripped circuit breaker defective switch or control cord Eliminate each p...

Страница 13: ...ranty period for tooling other items nonstandard or custom products described above and Huck shall inspect products for which such claim is made Tooling Part s and Other Items not manu factured by Huck HUCK MAKES NO WARRANTY WITH RESPECT TO THE TOOLING PART S OR OTHER ITEMS MANUFACTURED BY THIRD PARTIES HUCK EXPRESSLY DISCLAIMS ANY WARRANTY EXPRESSED OR IMPLIED AS TO THE CONDITION DESIGN OPERATION...

Страница 14: ...acturer of fastening systems and rings including specialty fasteners fluid fittings assembly components installation systems and seamless rings for aerospace and industrial applications Headquartered in Torrance California the company has over 8 300 employees at 39 manufacturing and distribution logistics locations in 13 countries For more information visit afsr alcoa com For The Long Haul The Fut...

Отзывы: