![Hubner UO-EM-EGS41 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/hubner/uo-em-egs41/uo-em-egs41_configuration-manual_2180884021.webp)
Configuration manual EGS(H)41
21
6
Monitoring screen
These pages are available to all users, as they do not permit any changes to the device settings.
Here you will find a graphic user interface based on the functions of an oscilloscope, for observation
and analysis of EGS(H) 41's switching behaviour.
Shown as curves:
The top section shows the current speed of EGS(H) 41 as a curve over time. It also shows the mini-
mum and maximum speeds during the measurement.
The bottom section shows the statuses of switching outputs S1, S2 and diagnosis together with the
following binary statuses of the following triggers.
The description is valid for signal representation as binary '1'
S1:
The switching output 1 is closed (ON)
C1:
Status monitoring for switching output 1 has triggered
S2:
The switching output 2 is closed (ON)
C2:
Status monitoring for switching output 2 has triggered
Diag:
The switching output Diag. is closed (ON)
Rotation: The current direction of rotation is clockwise
Still:
Standstill detected or slip detection triggered