background image

4  A1230-Control Software

4.1  Hardware and Software Requirements

To run the software, you need a computer running Windows 7 or Windows 10 and a free USB 
port.

4.2  Installation of the A1230-Control Software 

Insert the supplied USB stick into an USB port on your computer. Open the drive in Windows 
Explorer and locate to setup.exe.

Additional drivers and required additional programs are installed within the framework of the 
installation routine and require administrative access rights.

The driver devices required for the device are tested and do not represent any security risk! 
The possible security risks documented by your operating system due to non-certified 
drivers can be ignored.

Continue to follow the instructions on the screen.

The installation program generates the directory A1230-Control.

A1230-01 

A1230-Control Software

Page 11

Содержание A1230-01

Страница 1: ...Operating Manual A1230 01 4 Quadrant Voltage Amplifier 2 Channel DC 7 MHz 450 V s 185 W DC source 68 W DC sink Revision 2 0 MA 12300010...

Страница 2: ...lements 8 4 A1230 Control Software 11 5 Notes on Operation 16 6 Integration into Automated Test Systems 19 7 Maintenance and Service 22 8 Decommissioning and Disposal 23 9 Warranty 23 10 Contact Infor...

Страница 3: ...e device is equipped with a temperature controlled low noise fan Additionally an over temperature protection a power loss calculation and an absolute current monitoring guarantee perfect short circuit...

Страница 4: ...or serious injury Type and source of danger Indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury or property damage Type and source of danger Indic...

Страница 5: ...k of electric shock the device housing must be earthed and therefore always operate the device via the supplied three core power cable with protective conductor The mains cable may only be plugged int...

Страница 6: ...to be performed contact the manufacturer of the device 2 3 Intended Use 2 3 1 Hardware The device is intended exclusively for use as an LF power amplifier Typical applications are the operation as vol...

Страница 7: ...ser Operation may only be performed by qualified persons Reading and understanding the operating instructions Never use the device without having read and understood the operating instructions Always...

Страница 8: ...itched on 3 AMP IN 100 K BUTTON OFF 100 k input is switched off ON 100 k input is switched on 4 OUT OUT 4 mm safety sockets amplifier output Reference potential negative socket is connected to protect...

Страница 9: ...r is ready for operation READY Red Signals the intervention of a protection mechanism Red LED lights up constantly Over temperature protection the device switches on automatically after the drop of th...

Страница 10: ...4AT 5x20 mm 2 BRIDGE OUT BNC SOCKET Inverted preamp output for simple setup of bridge circuits 3 INTERLOCK BNC socket for interlock connection 4 COMPUTER USB USB socket for connecting to a computer em...

Страница 11: ...tup exe Additional drivers and required additional programs are installed within the framework of the installation routine and require administrative access rights The driver devices required for the...

Страница 12: ...artup configuration The amplifier then starts after the repeated switching on with the adjusted options 2 DEVICE saadfasdfasdfsd 3 INFO Here you find information about your GUI software version as wel...

Страница 13: ...ction must be reset manually The amplifier can now be switched on again Amplifier On 9 STATUS INDICATION Green Ready Signals the operational readiness of the amplifier Red short circuit_current exceed...

Страница 14: ...signal output of the amplifier can be turned on and off by clicking the appropriate box 4 3 2 Connect Menu The available amplifiers are listed with their corresponding port A connection is establishe...

Страница 15: ...n of the state of the 100 k input 4 INTERLOCK Setting the interlock mode LATCHING After an interlock the interlock state must be reset by a remote command before the amplifier can be switched through...

Страница 16: ...ep the power loss of the amplifier low the operating voltage should always be selected according to the load Example The load current IL should be 2 ADC Load 1 RL 25 For IL 2 ADC an output voltage UA...

Страница 17: ...e operation the cables should be as short as possible and of similar length The cable cross section should not fall below 1 5 mm The A1230 01 is a fast broadband amplifier that can deliver fast pulses...

Страница 18: ...t amplifier is connected to the 100 k input of the second amplifier Switch the 100 k input of the second amplifier on so you can control the entire output signal via the button of the selected input o...

Страница 19: ...1 99 default 1 which is determined by a command The address 100 is answered by all amplifiers regardless of the stored address 6 1 List of Remote Commands 0x01 Status query parameters no answer 1 Byt...

Страница 20: ...sion Parameters no answer 1 Byte revision 0x16 Set hardware revision Parameters 1 Byte revision e g 0x21 2 1 0x17 Query hardware revision Parameters no answer 1 Byte revision 0x53 Set Interlock Mode P...

Страница 21: ...turer s interface listed below Current devices https www lantronix com products deviceinstaller Older devices https www eztcp com en download ezmanager php Drivers and product information on the curre...

Страница 22: ...y Shipping without a pallet usually leads to considerable transport damage the costs of which we do not cover Please include the RMA number with the delivery e g on the delivery note Ensure that the p...

Страница 23: ...e product which was not damaged by negligence misuse improper installation accident or unauthorized repair or modification by the buyer This warranty is applicable only to defects due to material or w...

Страница 24: ...Bochum Germany Tel 49 234 970569 0 Fax 49 234 970569 29 service drhubert com www drhubert com 11 Guidelines This device complies with the relevant European Union harmonisation legislation EMC Directi...

Страница 25: ...12 Document History Revision Date Changelog 1 1 February 2020 First publication in new design 2 0 March 2020 Backpanel and frontpanel images were updated A1230 01 Document History Page 25...

Отзывы: