38
Triac:
•
Disconnect power.
•
Remove cover.
•
Disconnect the
RED
wire from the heating element, the
BLACK
wire from the power distribution block or
magnetic contactor (as applicable), and the
YELLOW
wire from the controller for the triac to be replaced.
NOTE: Replacement triacs come with replacement wires
attached.
•
Remove the two (2) nuts securing the triac to the heatsink
and remove the triac.
•
Spread a pea sized amount of the conductive thermal paste
included with the replacement kit on the back of the triac to be installed.
•
Install the replacement triac to the heatsink with the two (2) nuts removed previously.
•
Connect the
RED
wire to the heating element, the
BLACK
wire to the power
distribution block or magnetic contactor (as applicable), and the
YELLOW
wire to the
controller.
•
Re-install cover.
•
Turn on power.
Flow Meter:
•
Disconnect power.
•
Shut off cold water inlet and hot water outlet
valves.
•
Drain unit.
•
Remove cover.
•
Disconnect the flow meter wires from the
controller.
NOTE: The display may need to be removed to
access the wires from the flow meter. The
display can be removed by removing the four (4)
screws securing the display to the controller
standoffs and then pulling the display from the socket.
•
Disconnect the cold water supply pipe from the quick-connect fitting. See
Disconnecting a Joint in Section III.
•
Unscrew the quick-connect and coupling assembly from the flow meter.
•
Unscrew the flow meter from the inlet pipe.
•
Screw the replacement flow meter into the inlet pipe.
NOTE: Pipe dope must be used to seal the connection.
•
Screw the quick-connect and coupling assembly into the replacement flow meter.
NOTE: Pipe dope must be used to seal the connection
•
Re-connect the cold water inlet piping to the quick-connect connector. See Installation
of Quick-Connect Fitting in Section III.
•
Connect the flow meter wires to the controller. From left to right,
WHITE
/
GREEN
/
BROWN
.
•
Re-install cover.
•
Open the cold water inlet and hot water outlet valves
•
Bleed air from the unit. See Checking for Leaks and Purging Air in Section III.
•
Turn on power.
Содержание JHX
Страница 10: ...10...
Страница 16: ...16 Wiring Diagram 1 Wiring Diagram 2...
Страница 17: ...17 Wiring Diagram 3 Wiring Diagram 4...
Страница 20: ...20 Wiring Diagram 8...
Страница 22: ...22 Wiring Diagram 10...
Страница 30: ...30 Initial Evaluation...
Страница 43: ...43 NOTES...
Страница 44: ...44 P O BOX 288 STRATFORD CT 06615 0288 PHONE 203 378 2659 FAX 203 378 3593 INTERNET http www hubbellheaters com...