Hubbell Gai-Tronics REDA LERT 234 Скачать руководство пользователя страница 2

Pub. 42004-510C 

 

G A I - T R O N I C S

®

 

A   H U B B E L L   C O M P A N Y  

234/234SBA 

RED ALERT

®

 

 

Tower Assemblies

 

GAI-TRONICS  3030 KUTZTOWN RD.  READING, PA  19605 USA 

610-777-1374  

  800-492-1212  

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

Confidentiality Notice

 

This manual is provided solely as an installation, operation, and maintenance guide and contains sensitive 
business and technical information that is confidential and proprietary to GAI-Tronics.  GAI-Tronics 
retains all intellectual property and other rights in or to the information contained herein, and such 
information may only be used in connection with the operation of your GAI-Tronics product or system.  
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third 
party. 

General Information

 

The Model 234 RED ALERT Tower Assembly is part of a completely integrated emergency 
communications station.  The Model 234SBA RED ALERT Broadcast Tower Assembly helps ensure 
public safety by combining two-way communication with one-way public-address broadcasting. 

The Model 234 RED ALERT Tower and Model 234SBA RED ALERT Broadcast Tower are designed to 
house a GAI-Tronics 39

x

 or 27

x

 series flush-mount telephone and a Model 540-001 or 541-001 strobe.  

Both tower assemblies are over 9 feet tall, making them easily located by potential users.  The Model 
234SBA Tower can be equipped with up to four public address speakers. 

GAI-Tronics enhanced emergency telephones are designed for isolated high-risk areas requiring 
emergency communication equipment.  Emergency telephone users simply press the emergency push 
button for immediate connection to a user-programmed central security telephone number. 

The strobe creates added visibility to emergency telephone locations by providing a constant-on lamp that 
automatically flashes when the emergency button is pressed.  A panel light mounted in the tower shines 
on the front of the telephone to illuminate the telephone for nighttime use. 

The complete emergency communication tower assembly, with or without public address, is shipped in 
two stages.  The No. 84504-301 Hardware Kit is usually shipped in advance, followed by the remaining 
assemblies (No. 84501-201 or No. 84509-201 Tower Body, No. 84502-201 Clear Lens, and No. 84503-
30

x

 LED Panel Light Assembly).  Both the Model 234 and Model 234SBA use the same hardware kit. 

Tower Components

 

Each tower model includes components that are shipped separately for field assembly.  The included 
components are: 

Содержание Gai-Tronics REDA LERT 234

Страница 1: ...Components 1 Model 234 Tower 2 Model 234SBA Tower 2 Installation 2 Pier Foundation Depth and Conduit Entry 4 Concrete Form Construction 4 Anchor Bolt Location 6 Tower Mounting 7 Increased Windspeed R...

Страница 2: ...wer are designed to house a GAI Tronics 39x or 27x series flush mount telephone and a Model 540 001 or 541 001 strobe Both tower assemblies are over 9 feet tall making them easily located by potential...

Страница 3: ...c or Panel Light Assembly 10 33 V dc 1 4 12538 201 Speaker Kit quantity of kits determines audio coverage 1 4 12538 201 Vacancy Kit required when a speaker kit is not utilized i e facing a building Th...

Страница 4: ...ing nuts and washers needed for installation Additional materials required to install the pier are not provided by GAI Tronics but are shown in the installation drawings for reference Determine all co...

Страница 5: ...see Figure 2 for typical conduit arrangements Figure 2 Sample conduit arrangements within tower Concrete Form Construction 1 Place the 24 inch diameter concrete form tube on a bed of crushed stone in...

Страница 6: ...Pub 42004 510C 234 234SBA RED ALERT Tower Assemblies Page 5 of 14 P Standard IOMs Current Release 42004 Instr Manuals 42004 510C docx 11 19 Figure 3 Reinforcement Cage Detail...

Страница 7: ...or bolts a minimum of nine inches into the concrete Anchor bolt positioning is critical for tower body mounting 1 Immediately submerge the anchor bolts into the concrete pier after pouring the concret...

Страница 8: ...or the bolt protrusion dimension Figure 5 Concrete Pier Cross Section Tower Mounting ATTENTION Do not mount the tower body until the concrete has been allowed to cure for a minimum of 24 hours 1 Threa...

Страница 9: ...11 19 Figure 6 Exploded View 4 Verify that a inch minimum air gap exists between the base of the tower and the top of the concrete pier see Figure 7 NOTE The air gap must not be obstructed with soil...

Страница 10: ...s highly recommended that this extension be installed The extension increases the installation height of the LED strobe for maximum visibility 1 Thread the extension onto the tower and tighten 2 Inser...

Страница 11: ...ires will be connected later to the incoming power conductors in accordance with applicable electrical codes Model 84503 302 10 33 V dc Extend the black and the white wires to the base of the tower th...

Страница 12: ...nnection to the electronics paging module before placing the batteries into the tower NOTE Leave the wires from the paging module to the batteries disconnected until ready to power up the unit 2 Secur...

Страница 13: ...42004 Instr Manuals 42004 510C docx 11 19 Power Connections For all component wiring refer to the specific equipment manual and the interconnection diagrams see Figure 11 and Figure 12 Figure 11 Inter...

Страница 14: ...ng by treating it with a phosphoric acid solution intended for this purpose Allow the area to dry 4 Using a cotton swab or small brush paint the prepared surface with an automotive enamel or oil base...

Страница 15: ...02 EMERGENCY reflective label white 25398 003 EMERGENCY standard label cardinal red 25398 013 EMERGENCY standard label black 25398 015 HELP large label white 540 001 Strobe 120 V ac 541 001 Strobe 12...

Страница 16: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...