background image

Pub. 42004-461D 

f:\standard ioms - current release\42004 instr. manuals\42004-461d.doc 
07/14

G A I - T R O N I C S ®  

A   H U B B E L L   C O M P A N Y  

Hands-free VoIP Retro-Fit Telephones 

Confidentiality Notice 

This manual is provided solely as an installation, operation, and maintenance guide and contains sensitive 
business and technical information that is confidential and proprietary to GAI-Tronics.  GAI-Tronics 
retains all intellectual property and other rights in or to the information contained herein, and such 
information may only be used in connection with the operation of your GAI-Tronics product or system.  
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party. 

Product Overview 

RED ALERT

®

 VoIP Retro-Fit Telephones are designed for connection to a 10/100 baseT Ethernet.  

These telephones will operate from Power-over-Ethernet or an external power source.  The VoIP 
Telephones provide direct point-to-point communications between personnel throughout the facility over 
the existing LAN.  The appropriate RED ALERT

®

 retrofit models are designed to replace Code Blue, 

Ramtel, or Talk-A-Phone telephones utilizing a six-hole mounting pattern. 

The following RED ALERT

®

 VoIP Retro-Fit Telephones are detailed in this manual: 

Table 1.  Model Chart 

Model Description 

397-700CB  Code Blue Flush-Mount Hands-free VoIP Telephone

, weatherproof brushed stainless 

steel front panel, 

HELP

 

autodial push button, and 

CALL

 

RECEIVED

 

WHEN

 

LIT

 LED. 

397-700TP 

Talk-A-Phone Flush-Mount Hands-free VoIP Telephone

, weatherproof brushed 

stainless steel front panel, 

HELP

 

autodial push button, and 

CALL

 

RECEIVED

 

WHEN

 

LIT

 

LED. 

397-700RT  Ramtel Flush-Mount Hands-free VoIP Telephone

, weatherproof brushed stainless steel 

front panel, 

HELP

 

autodial push button, and 

CALL

 

RECEIVED

 

WHEN

 

LIT

 LED. 

398-702CB  Code Blue Flush-Mount VoIP Telephone

, weatherproof brushed stainless steel front 

panel, 

HELP

 autodial push button, 

CALL

 (off-hook) button, 12-button Braille keypad, and 

CALL

 

RECEIVED

 

WHEN

 

LIT

 LED.

 

398-702TP 

Talk-A-Phone Flush-Mount VoIP Telephone

, weatherproof brushed stainless steel front 

panel, 

HELP

 autodial push button, 

CALL

 (off-hook) button, 12-button Braille keypad, and 

CALL

 

RECEIVED

 

WHEN

 

LIT

 LED.

 

Содержание GAI-Tronics RED ALERT 397-700CB

Страница 1: ...5 Features and Functions 5 Operation 6 Autodial Emergency Call 6 All Models 6 Placing a Telephone Call using Keypad 6 Models 398 702CB 398 702RT and 398 702TP 6 Receiving a Call 6 Multicast Broadcast...

Страница 2: ...0 796 5954 VISIT WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS Heartbeat 19 EACT 19 Programming 19 VoIP PCBA Setup 19 VoIP PCBA Initial Network Configuration 19 Maintenance 20 General Informa...

Страница 3: ...t the facility over the existing LAN The appropriate RED ALERT retrofit models are designed to replace Code Blue Ramtel or Talk A Phone telephones utilizing a six hole mounting pattern The following R...

Страница 4: ...V dc power source for operation Two VoIP telephones can be connected in a peer to peer configuration without the need for a LAN However a 10 100 BaseT Ethernet with SIP server is required for systems...

Страница 5: ...ions of your 911 service If your power is out or your internet connection is down be aware that your VoIP service may not work Consider installing a backup power supply maintaining a traditional phone...

Страница 6: ...wing the receiving caller or the defined timeout of the call duration or the SIP server Placing a Telephone Call using Keypad Models398 702CB 398 702RT and398 702TP To place a general telephone call u...

Страница 7: ...e which can override which A telephone with Multicast enabled can still make and receive normal calls peer to peer or SIP server Normal calls can be assigned a priority level defining whether calls ca...

Страница 8: ...S FREE VOIP RETRO FIT TELEPHONES PAGE 8 of 23 f standard ioms current release 42004 instr manuals 42004 461d doc 02 15 Figure 1 Model 397 700CB Figure 2 Model 397 700RT Figure 3 Model 397 700TP Figure...

Страница 9: ...PUB 42004 461D HANDS FREE VOIP RETRO FIT TELEPHONES PAGE 9 of 23 f standard ioms current release 42004 instr manuals 42004 461d doc 02 15 Figure 5 Model 398 702RT Figure 6 Model 398 702TP...

Страница 10: ...essary not to cause harmful interference Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference a...

Страница 11: ...ing through the cable entry hole 4 The connecting line should be equipped with an RJ45 modular connector Plug the connector into the mating network connector on the VoIP PCBA mounted to the Carrier PC...

Страница 12: ...PUB 42004 461D HANDS FREE VOIP RETRO FIT TELEPHONES PAGE 12 of 23 f standard ioms current release 42004 instr manuals 42004 461d doc 02 15 Figure 7 Back Box for Ramtel RT and Code Blue CB...

Страница 13: ...PUB 42004 461D HANDS FREE VOIP RETRO FIT TELEPHONES PAGE 13 of 23 f standard ioms current release 42004 instr manuals 42004 461d doc 02 15 Figure 8 Back Box for Talk A Phone TP...

Страница 14: ...med in accordance with NEC 725 55 Power Power Over Ethernet Connect power to the system as indicated in your PoE equipment manual Local Power When PoE is not available a separate isolated 24 48 V dc p...

Страница 15: ...ES PAGE 15 of 23 f standard ioms current release 42004 instr manuals 42004 461d doc 02 15 NetworkCable Connect a Cat5 or Cat5e UTP cable with an RJ45 connector between the Local Area Network LAN and t...

Страница 16: ...ed on terminal block P12 Table 3 Auxiliary Inputs P12 Pin Label Function 1 IN4 Input 4 2 COM Common 3 IN3 Input 3 4 COM Common 5 IN2 Input 2 6 COM Common 7 IN1 Input 1 8 COM Common Outputs Two outputs...

Страница 17: ...Activation of these inputs can be configured to update a SYSLOG or generate an email Please refer to Figure 9 on page 15 of this manual and the Logic Settings section of GTC Pub 42004 396 VoIP Telepho...

Страница 18: ...acons video cameras and alarm generators to be activated when the HELP push button is pressed The relay can remain energized for the duration of the emergency call In most applications this output is...

Страница 19: ...ing to configure the GAI Tronics VoIP Telephones The general sequence for set up of the VoIP telephone is as follows VoIP PCBA Setup The easiest way to get started is to make a network connection to t...

Страница 20: ...ove with a non abrasive commercial cleanser and water Rub stained areas in the same direction as the existing grain Stubborn stains may be removed with a paste made from magnesium oxide ammonia and wa...

Страница 21: ...uration Front panel push buttons are not operational Verify the push buttons are properly configured Inputs not operational Check the input connections Verify the inputs are properly configured Output...

Страница 22: ...t Not available on all models Outputs Output 1 8 A 30 V ac dc resistive load Output 2 8 A 30 V ac dc resistive load Indicators External Off hook indicator light Internal on VoIP PCBA Power Heartbeat E...

Страница 23: ...el 398 702CB Panel 11 75 H 8 50 W inches 298 4 215 9 mm Back box depth from mounting surface 2 56 inches 65 0 mm Weight 7 0 lbs 3 2 kg Approval Standards Compliance to Standard FCC CRF 47 Part 15 Encl...

Страница 24: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: