Outputs
The telephones have two dry-contact outputs for customer use. Terminate these outputs to connector
P2
on the relay PCBA (see Figure 6).
Table 5. Output Contacts—Connector P2
Pin
Label
Description
1
C2
Common Output 2
2
NO2
Normally Open Output 2
3
C1
Common Output 1
4
NO1
Normally Open Output 1
Relay capacity is 5 A at 30 V dc or 120 V ac.
USB port
The USB port is for GAI-Tronics service personnel only. Make no connection to this port.
Front Cover Installation
After all wiring and cable connections are complete:
1.
Place the front panel on the rear enclosure.
2.
Do not to pinch any cables.
3.
Secure the front panel using the four screws and washers provided.
4.
Torque the screws to 10–12 in
lb (1.13–1.36 N·m).
Programming
The network configuration must provide VoIP service (using the SIP protocol) between the desired
locations before attempting to configure a GAI-Tronics VoIP telephone.
The general sequence to set up a VoIP telephone is as follows:
VoIP Telephone Setup
1.
Connect a PC to the same network as the VoIP telephone.
2.
Log into the unit’s web interface.
The unit is factory configured with a static IP address:
192.168.1.2.
3.
Enter the username and password when prompted.
The initial factory settings are:
•
U
SER
N
AME
:
user
•
P
ASSWORD
:
password
4.
Change the username and password upon first login.
This security measure helps prevent unauthorized changes to the VoIP telephone’s interface
configuration.