11/09

 

Installation 

General Information 

WARNING

 

This product can contain hazardous voltages.  Always remove power to this 

station and any associated equipment before beginning any installation. 

CAUTION

Do not install this equipment in areas other than those indicated on the 

approval listing in the Specification section of this manual.  Such installation may cause a safety 
hazard and consequent injury or property damage.

 

Install equipment without modification and according to all applicable local and national electrical codes.  
Consult the National Electrical Code (NFPA 70), Canadian Standards Association (CSA 22.1), and local 
codes for specific requirements regarding your installation.  Class 2 circuit wiring must be performed in 
accordance with NEC 725.55. 

Safety Guidelines 

When installing any GAI-Tronics equipment, please adhere to the following guidelines to ensure the 
safety of all personnel: 

 

Do not install wiring during a lightning storm. 

 

Electrostatic Discharge (ESD) Protection:

 Your VoIP telephone may have an earth ground terminal 

provision.  If so, ensure that it is connected to ground in accordance with all local safety regulations 
and the National Electrical Code (NEC).  Grounding has to be ensured for safe and stable 
communications.  Do not use long and coiled ground wires.  Trim ground wires to the required 
length.  Use a star configuration whenever possible.  Please note proper grounding does not eliminate 
the need for lightning protection for the telephone or the telephone system. 

 

Do not install jacks in wet locations unless the jack is specifically designed for wet locations. 

Station Placement 

To prevent feedback problems in the system, volume settings, and station placement must be taken into 
consideration.  Unpleasant feedback problems can be reduced by: 

 

Pointing the telephone away from other telephones located nearby 

 

Reducing volume levels 

Tamper-Resistant Hardware 

All of the telephones described in this manual are vandal resistant.  The front panel for each telephone 
covered in this manual is attached to its enclosure with tamper-resistant screws.  A GAI-Tronics Model 
233-001 Tamper-Resistant Screwdriver (sold separately) is recommended for installing the tamper-
resistant screws. 

Содержание GAI-TRONICS 293-700

Страница 1: ...00 293AL 700 294AL 702 297 700 297 701 298 702 3 Placing a Non Emergency Call 3 Models 294AL 702 298 701 298 702 3 Models 297 701 297 702 and 297 703 3 Americans with Disabilities Act ADA Functionalit...

Страница 2: ...NICS COM FOR PRODUCT LITERATURE AND MANUALS Speaker Level Remote Control 15 Programming 16 Quick Start Guide 16 Alternative Configuration Methods 17 Maintenance 18 General Information 18 Preventive Ma...

Страница 3: ...The vandal resistant phone is housed in a cast aluminum enclosure painted safety yellow that is designed to be surface mounted and includes an emergency push button 294AL 702 VoIP Phone with Keypad A...

Страница 4: ...AN media capabilities and the services available at each end point Tips for VoIP Subscribers If you have or are thinking of subscribing to an interconnected VoIP service you should Provide your accura...

Страница 5: ...on emergency autodial call 1 Press the black autodial push button to place an immediate call to a preprogrammed number 2 On the Model 297 701 only the CALL RECEIVED WHEN LIT LED will light steady when...

Страница 6: ...Electrostatic Discharge ESD Protection Your VoIP telephone may have an earth ground terminal provision If so ensure that it is connected to ground in accordance with all local safety regulations and...

Страница 7: ...sure from the bottom Sealed fittings should be installed at all cable entry points Silicone sealant or equivalent should be applied around and inside all conduit entries Please refer to the examples b...

Страница 8: ...t is equivalent in size to the conduit diameter Bottom entry is strongly recommended Insert a conduit fitting in the access hole Refer to conduit installation details on page 5 NOTE Use silicone seala...

Страница 9: ...TELEPHONES PAGE 7 of 23 f standard ioms current release 42004 instr manuals 42004 397g doc 11 09 Figure 6 Model 293AL 700 Figure 7 Model 294AL 702 Figure 8 Component Locations for Models 293 700 293A...

Страница 10: ...ate hardware Refer to Figure 15 cutout dimensions 2 Remove the tapered plug from the top or bottom cable entry hole in the back box and install the cable and cable fitting See the Field Wire Installat...

Страница 11: ...004 397G VOIP TELEPHONES PAGE 9 of 23 f standard ioms current release 42004 instr manuals 42004 397g doc 11 09 Figure 11 Model 297 701 Figure 12 Model 297 702 Figure 13 Model 297 703 Figure 14 Model 2...

Страница 12: ...PUB 42004 397G VOIP TELEPHONES PAGE 10 of 23 f standard ioms current release 42004 instr manuals 42004 397g doc 11 09 Figure 15 Flush Mount VoIP Telephone Mounting Details...

Страница 13: ...fer to Figure 16 for wiring details Refer to Table 1 on page 12 for the recommended conductor sizes NOTE Consult the National Electrical Code NFPA 70 Canadian Standards Association CSA 22 1 and local...

Страница 14: ...an RJ45 connector between the Local Area Network LAN and the VoIP PCBA I O Inputs Four auxiliary inputs have been provided for customer use Terminations for these inputs are provided on terminal bloc...

Страница 15: ...acons video cameras and alarm generators to be activated when the EMERGENCY push button is pressed The relay remains energized for the duration of the emergency call In many applications the output is...

Страница 16: ...ndset microphone only Set the Handset Enable HNDST jumper to Y for handset telephones and to N for hands free telephones This jumper will be factory set for proper default operation InductiveLoopSourc...

Страница 17: ...ing the wiper to the end of the potentiometer range Example Volume Increase Short across P14 The volume begins to decrease Remove short across P14 and wait 1 second Short across P14 again The volume b...

Страница 18: ...onfiguration Mounting Physically mount the phone at the intended location Installation Provide phone connections and cabling to the network at the intended location Final configuration can also be don...

Страница 19: ...ld within the telephone can be accessed over the network using a browser such as Internet Explorer to view and change settings within a single unit Configuration files are ASCII text files containing...

Страница 20: ...rrosion or rusting is noticed remove with a non abrasive commercial cleanser and water Rub stained areas in the same direction as the existing grain Stubborn stains may be removed with a paste made fr...

Отзывы: