This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA.  On this
equipment is a label that contains, among other information, a product identifier in the format
US:AAAEQ##TXXXX.  If requested, this number must be provided to the telephone company.

A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the
applicable FCC Part 68 rules and requirements adopted by the ACTA.  A compliant telephone cord and modular
plug is provided with this product.  It is designed to be connected to a compatible modular jack that is also
compliant.  See installation instructions for details.

The REN is used to determine the number of devices that may be connected to a telephone line.  Excessive RENs on
the telephone line may result in the devices not ringing in response to an incoming call.  In most but not all areas, the
sum of the RENs should not exceed five (5.0).  To be certain of the number of devices that may be connected to a
line, as determined by the total RENs, contact the local telephone company.  For products approved after July 23,
2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX.  The
digits represented by ## are the REN without a decimal point (e.g., 03 is an REN of 0.3).  For earlier products, the
REN is separately shown on the label.

If this equipment [GAI-Tronics telephone] causes harm to the telephone network, the telephone company will notify
you in advance that temporary discontinuance of service may be required.  But if advance notice isn’t practical, the
telephone company will notify the customer as soon as possible.  Also, you will be advised of your right to file a
complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect
the operation of the equipment.  If this happens the telephone company will provide advance notice in order for you
to make necessary modifications to maintain uninterrupted service.

If trouble is experienced with this equipment [GAI-Tronics telephone], for repair or warranty information, please
contact GAI-Tronics Corporation at 800-492-1212 or www.gai-tronics.com.  If the equipment is causing harm to the
telephone network, the telephone company may request that you disconnect the equipment until the problem is
resolved.

Connection to party line service is subject to state tariffs.  Contact the state public utility commission, public service
commission or corporation commission for information.

User Instructions (Canada) CP-01, Issue 8, Part I: Section 14.1

NOTICE:  

The Industry Canada label identifies certified equipment.  This certification means that the equipment

meets certain telecommunications network protective, operational and safety requirements as prescribed in the
appropriate Terminal Equipment Technical Requirements document (s).  The Department does not guarantee the
equipment will operate to the user's satisfaction.  Before installing this equipment, users should ensure that it is
permissible to be connected to the facilities of the local telecommunications company.  The equipment must also be
installed using an acceptable method of connection.  The customer should be aware that compliance with the above
conditions may not prevent degradation of service in some situations.  Repairs to certified equipment should be
coordinated by a representative designated by the supplier.  Any repairs or alterations made by the user to this
equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to
disconnect the equipment.  Users should ensure for their own protection that the electrical ground connections of the
power utility, telephone lines and internal metallic water pipe system, if present, are connected together.  This
precaution may be particularly important in rural areas.

CAUTION

Users should not attempt to make such connections themselves, but should contact the appropriate electric
inspection authority, or electrician, as appropriate.

CP-01, Issue 8, Part I: Section 14.2

NOTICE:

  The 

Ringer Equivalence Number

 (REN) assigned to each terminal device provides an indication of the

maximum number of terminals allowed to be connected to a telephone interface.  The termination on an interface
may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence
Numbers of all the devices does not exceed 5.

Содержание GAI-TRONICS 293-001

Страница 1: ...298 001 Only 3 Americans with Disabilities Act ADA Functionality 4 Installation 5 Safety Guidelines 5 General Installation Guidelines 5 Tamper Resistant Hardware 5 Conduit Installation Details 6 Model...

Страница 2: ...cast aluminum enclosure painted safety yellow that is designed to be surface mounted and includes a 12 button Braille keypad an emergency push button and a call off hook button 297 001 Flush panel Em...

Страница 3: ...uration Answering options All of the above telephones are line powered telephones and can be connected to any of the following Central Office CO line to the Public Switched Telephone Network PSTN 24 V...

Страница 4: ...1 2 The emergency operator must press the key to acknowledge the call 3 Once acknowledged the CALL RECEIVED WHEN LIT lamp on the phone s front panel illuminates and communication can begin PlacingaNon...

Страница 5: ...The telephone detects the DTMF signal and transmits a three digit location identification code to identify which emergency telephone is originating the call This location code can be displayed on a D...

Страница 6: ...ith the phone Please consult our Service Center at 800 492 1212 for further information Do not install telephone jacks in wet locations unless the jack is specifically designed for wet locations Do no...

Страница 7: ...e enclosure from the bottom Sealed fittings should be installed at all cable entry points Silicone sealant or equivalent should be applied around and inside all conduit entries Please refer to the exa...

Страница 8: ...e Refer to conduit installation details on page 6 NOTE Use silicone sealant or equivalent around and inside all conduit entries 4 Pull the telephone line through the conduit Connect the telephone line...

Страница 9: ...ANT EMERGENCY PHONES PAGE 8 of 29 d standard ioms current release 42004 instr manuals 42004 352k doc 06 06 Figure 6 Model 293AL 001 Figure 7 Model 294AL 001 Figure 8 Models 293 001 293AL 001 and 294AL...

Страница 10: ...e telephone line and cable fitting 4 Telephone line connections directly to TB1 are acceptable 5 If using the modular jack remove the cover and connect the red and green wires of the telephone line to...

Страница 11: ...PUB 42004 352K ADA COMPLIANT EMERGENCY PHONES PAGE 10 of 29 d standard ioms current release 42004 instr manuals 42004 352k doc 06 06 Figure 11 Model 297 001 and 298 001 Mounting Details...

Страница 12: ...ase 42004 instr manuals 42004 352k doc 06 06 Figure 12 Model 297 001 and 298 001 Component Locations shown with connection to optional GAI Tronics 530FB 531A Beacon Connecting a Beacon Figure 12 above...

Страница 13: ...pins 2 and 3 Disable Insert the J14 jumper on pins 1 and 2 Do not use this setting except under the direction of GAI Tronics personnel NOTE The Auto answer feature must be enabled during remote progr...

Страница 14: ...to Figure 13 for the location of TB2 The auxiliary output allows peripheral equipment such as beacons video cameras and alarm generators to be activated when the EMERGENCY push button is pressed The r...

Страница 15: ...en the front panel is tightly mounted in the enclosure After making any volume adjustments we recommend mounting the front panel to the enclosure and testing the phone again Automatic Line Level Compe...

Страница 16: ...Disconnect the keypad from J13 12 Install the phone in the back box or enclosure For emergency phones with a CALL push button and keypad Disable password protection by removing the jumper from J9 1 P...

Страница 17: ...mper on pins 2 and 3 3 Using a touch tone telephone call the emergency telephone The emergency telephone automatically answers the call and generates a splash tone followed by a success tone single be...

Страница 18: ...See Figure 8 and Figure 12 for details Contact GAI Tronics Field Service Department for details 2 Temporarily move the EMERGENCY push button switch harness from connector J7 to the CALL push button co...

Страница 19: ...ameters See the Programming Sequences section below A success tone single tone DTMF tone is generated each time a new parameter is accepted An error tone double beep is generated to indicate an error...

Страница 20: ...he first backup or roll over number Again in the event an emergency call cannot connect to first back up telephone number the emergency phone will automatically dial the second backup or roll over num...

Страница 21: ...sequence ends in 2 instead of 1 None Emergency Button Auto dial Number 3 DD 3 Same as Emergency Button Auto dial Number 1 except the sequence ends in 3 instead of 1 None Call Button Auto dial DD 4 Sa...

Страница 22: ...oringFeature When the Silent Monitoring feature is enabled the splash tone is eliminated and silent monitoring can begin without notifying individuals near the telephone Feature Key Sequence Descripti...

Страница 23: ...sconnect Option 1 2 N N This feature programs the maximum length of a call if no other disconnect features are used The valid entries are 1 99 representing 1 minute increments and 0 representing 4 5 h...

Страница 24: ...es the three digit location identification ID number To enable the ID feature set L 1 To disable the ID feature L 0 Enter the three digit location identification code in the sequence N N N For Example...

Страница 25: ...gency Button Auto dial Number 2 DD 2 None Emergency Button Auto dial Number 3 DD 3 None Call Button Auto dial Number DD 4 None Primary Dial Tone Delay 10NN Infinite Secondary Line Dial Tone Delay 11NN...

Страница 26: ...authorization number RA Equipment should be shipped prepaid to GAI Tronics with a return authorization number and a purchase order number If the equipment is under warranty repairs will be made witho...

Страница 27: ...n PCBA printed circuit board assembly Conformal coated Model 293 001 Enclosure construction Valox high impact glass reinforced polyester painted safety yellow Dimensions 9 5 H 8 W 4 D inches 241 3 203...

Страница 28: ...er 4B Connection Method CA11A Replacement Parts Part No Description 293 001 293AL 001 294AL 001 297 001 298 001 233 001 Model 233 001 Tamper Resistant Screwdriver 12562 102 Emergency PCBA Replacement...

Страница 29: ...ble is experienced with this equipment GAI Tronics telephone for repair or warranty information please contact GAI Tronics Corporation at 800 492 1212 or www gai tronics com If the equipment is causin...

Страница 30: ...ide and contains sensitive business and technical information that is confidential and proprietary to GAI Tronics GAI Tronics retains all intellectual property and other rights in or to the informatio...

Страница 31: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Отзывы: