Mounting

A concrete pier is required to support the stanchion.
GAI-Tronics provides the Model 84504 Hardware Kit
to aid with the construction of this pier.

We recommend using as a minimum, 3,000 psi grade
concrete.  The pier must be strong enough to support a
structure that is 9 

1

/2

-feet tall and weighs 225 lbs.

Reinforcement Cage

We recommend that the concrete base be 3 feet deep
and 18 inches wide, and that a reinforcement cage be
used.  The reinforcement cage is not provided by
GAI-Tronics.  The following materials are necessary
to construct the reinforcement cage:

 

four #4 rebars;

 

three #4 ties;

 

one 18-inch sonotube.

1.

 

Construct the reinforcement cage by placing a horizontal
member in the center of the rebar.

2.

 

Place the two remaining horizontal members 12 inches
from that center point.  See Figure 2.  The top of the
cage should be 3 inches below the top of the pier.

3.

 

The reinforcement cage in Figure 2 shows the maximum
diameter that is suitable for a customer-provided 18-inch
sonotube.

4.

 

Install two conduits in the pier—one for the telephone
wire and one for the electrical power wire.

N

OTE

:

  These conduits MUST be kept separate to

prevent interference from occurring on the audio lines.
Conduits are not supplied by GAI-Tronics.

Figure 1.  Complete Emergency Station

Figure 2.  Reinforcement Cage

Содержание GAI-TRONICS 234

Страница 1: ...uals to assist in properly installing a complete station Pub No Emergency Phone Model Pub 42004 284 Model 530FB Strobe with Dual Constant On Lamps Pub 42004 352 Model 297 001 Flush Mount Emergency Pho...

Страница 2: ...AI Tronics The following materials are necessary to construct the reinforcement cage four 4 rebars three 4 ties one 18 inch sonotube 1 Construct the reinforcement cage by placing a horizontal member i...

Страница 3: ...Grounding electrode conductor not depicted in the illustration must be constructed in accordance with the National Electrical Code and applicable local codes Model 84504 Hardware Kit Installation The...

Страница 4: ...chion Assembly Page 4 of 11 d standard ioms current release 42004 instr manuals 42004 194h doc 09 05 NOTE The stanchion should not be mounted until the concrete has been allowed to cure for a minimum...

Страница 5: ...hex nut See Figure 5 and Figure 6 3 Before mounting the stanchion unscrew the four tamper resistant screws on the rear handhole cover and remove the cover 4 Apply a small amount of clear RTV silicone...

Страница 6: ...st exist between the base of the stanchion and the top of the concrete pier See Figure 6 This air gap must not be obstructed with soil mulch stone etc The unit should be installed and grounded in acco...

Страница 7: ...hot and the white neutral wires to the base of the stanchion these wires will be connected later along with the beacon wires to the incoming power wires in accordance with the electrical codes 4 Secu...

Страница 8: ...res to extend to the base of the stanchion See Figure 8 2 Screw the beacon onto the threaded nipple Secure the lens cover Model 84502 with four tamper resistant screws 3 Apply a small amount of clear...

Страница 9: ...ly on the protection bracket on the bottom of the stanchion wall mounting assembly 4 Install a ground wire between the telephone line surge suppressor sold separately and the grounding lug on the bott...

Страница 10: ...accordance with the National Electrical Code NEC in the United States or the Canadian Electrical Codes CEC in Canada Install the power lines as follows 1 Install the recommended ac power line surge s...

Страница 11: ...e to loosen and lift a corner edge of the damaged decal 2 Carefully peel back and remove the loosened decal 3 Wipe the area clean with denatured alcohol Allow the area to dry 4 Prior to attaching a ne...

Страница 12: ...be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of services provided hereunder Warranty Periods Every...

Отзывы: