Pub. 42004-519C
Rugged VoIP Autodial Handset Telephones
Page 7 of 26
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-519C.docx
10/19
Model 227-700
The mounting and cabling instructions for the Model 227-700 Telephone are as follows:
1.
Remove the eight security screws
from the front panel using a GAI-
Tronics No. 233-001Security
Screwdriver.
2.
Remove the front panel and set it
aside.
3.
Determine the hole pattern to use
for mounting the telephone (see
Figure 8).
•
Use the 7.875 × 4.0-inch hole
pattern for mounting to a wall
(outside pattern).
•
Use the 5.25 × 4.0-inch hole
pattern when using the No.
232-001 Pole Mounting Kit
(inside pattern).
4.
Insert (four provided) hole plugs
in the unused mounting holes.
5.
Position the enclosure on the
mounting surface and secure it with four
fasteners.
•
The holes in the telephone enclosure
accept 3/8-inch screws or bolts.
•
The Model 232-001 Pole Mounting Kit
includes four 3/8-16 × 1-inch shoulder
bolts with Teflon seal washers.
N
OTE
:
Use only the round head, hexagon
head, or pan head screws that are
provided. Do not use screws designed
to be countersunk for mounting the
enclosure.
6.
Install a conduit fitting in one of the 1/2-inch
NPT conduit entrances located at the top and
bottom of the unit.
The bottom location is preferred (see Figure 7).
7.
Insert the conduit into the fitting.
8.
Plug the unused access hole with the provided
3/8-inch Allen drive plug.
N
OTE
:
Use silicone sealant or equivalent
around and inside all conduit entries.
9.
Pull the Ethernet cable through the conduit and
install the cable (see the Network section).
10.
Connect peripheral devices (see the Auxiliary
I/O section).
Figure 6. Model 227-700 VoIP Autodial Telephone
with spring loaded door in the open position
Figure 7. Model 227-700 Outline