INSTALLATION INSTRUCTIONS 

Miniliter IV 

MHSY Series 

WARNING

 

DISCONNECT POWER DURING INSTALLATION AND BEFORE SERVICING. 
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION

 

OPTIONAL PHOTOCONTROL (PBT SERIES) FIELD INSTALLATION (MHS­Y)

 

1. Remove two screws (5) and cover (6) 
2. Drill a 11/16 diameter hold in the centre of cover (6) 
3. Mount the photocontrol on the inside of the cover according to directions 
supplied with the photocontrol. 
4. Replace cover (6) and tighten screws (5).

 

FIXTURES NOT MARKED IP65

 

A. For up­aimed fixtures use a hammer and a 
Screwdriver to knock out the two thin 
Sections C located at the rear bottom 
Corners. 
B. For down­aimed fixtures­ remove the #10 drain 
Hole screw (19) located a the front bottom 
Centre.

 

FIXTURES MARKED IP65

 

If the fixture is marked IP65 do not remove 
Section C and do not remove the drain hold 
Screw (19)

 

FUSE REPLACEMENT (MHS­XXXX­46X­FX)

 

1. Turn off power before servicing. 
2. Open lens door and remove lamp. 
3. Remove the 2 socket retaining screws, socket 
And retainer. 
4. Remove the 4 reflector screws, and carefully 
remove three reflector segments. 
5. Lift barrier if present to expose fuse holder. 
6. Open the fuse holder 
7. Replace the blown fuse with the same fuse 
type and rating and close fuse holder. 
8. Replace the barrier, reflector segments and 
four reflector screws. 
9. Replace lamp and close lens door.