background image

Page 3 

Kim Lighting • 16555 E. Gale Ave. • City of Industry, CA  91716-0080 • 626/968-5666 • FAX 626/330-3861

WARNING:

The H.I.D. / Fluorescent fixture utilizes a lamp that

may contain mercury.  For information on disposal of

lamp go to website:  

www.lamprecycle.org

Vandal Resistant Bollard 

Installation Instructions

VRB1/VRB3 & VRB2/VRB4

3. Install lamp of type and wattage shown on fixture

label.  Make sure globe gasket surface is clean.
Reinstall globe and retaining strap making certain
pressure pad is in place around retaining strap
before installing hex nuts.

4. Replace top cap by aligning screws with keyhole

slot openings.  Turn top cap counterclockwise and
tighten screws.

BALLAST REPLACEMENT INSTRUCTIONS:

Make certain the electrical supply is 

OFF

before starting replacement.

3. Place fixture over the ballast assembly and slowly turn until it drops into retaining slots; twist shaft clockwise 45° to

lock onto the base casting.  Tighten the two set screws at the base of the fixture.

!

LAMP INSTALLATION OR REPLACEMENT INSTALLATION INSTRUCTIONS 

cont'd.

1. Loosen two 

J

-20 set screws located near bottom

of fixture using a 

F

” hex key.  Rotate the fixture

counterclock-wise approximately 1” and lift upward
to clear ballast assembly.

2. Replace ballast with the correct type and wattage.

Connect all wiring as shown in the wiring diagram
on the new ballast.