ORBEON INSTALLATION INSTRUCTIONS
page 2
WARNING
:
TO AVOID DAMAGE TO LED LAMPS, AC POWER SUPPLY MUST BE TURNED OFF BEFORE
CONNECTING OR DISCONNECTING SECONDARY WIRING CONNECTIONS.
INSTRUCTIONS: (ENSURE THAT POWER IS TURNED OFF)
1. Verify that input power is 120-277 VAC.
2. Loosen Phillips screw that holds the bracket to the housing. Remove bracket from Orbeon housing.
3. If provided with the optional bird guard, secure bracket to the housing using screws provided.
4. Attach the mounting bracket to the junction box (by others) using screws (by others). Junction box may
be recessed (as shown), surface mounted or suspended. Assure bracket is square with traffic for aesthetics.
Observe “street side” label if directional optics are provided. Street side label should be mounted to match the
direction of traffic flow.
Ceiling Surface
Conduits and Primary
Wiring (by others)
Concrete
(by others)
2
4
Mounting Bracket
.75
3.5
2.75
1.75
6.0
Screw
Bird Guard
Align the guard such that this
notch is opposite of the screw
3