background image

PD2665 

(PAGE 2)

 

05/17

 

1 Enclosure

  2  Mounting foot

   3   Drill spots

  4  Terminal screws

    5   Grounding buss

  6  Ground buss mounting screw

  7  User installed thru-feed conduit entrance

   8  Switch

   9  Neutral buss

 10   Breather drain (not included)

 11  User installed conduit entrance for dual bottom feed

 12  Switch release tab.  Pull to remove switch

 13  Listed/Certified conduit hub rated 

       Type 4X,12  (One supplied)

 14  LINKOSITY Power out

 15  Align rib with slot

 

7. Select the correct wiring diagram. Loosen terminal screws. Insert conductors fully into proper terminals.

  8.Tighten terminal screws as follows: SWITCH

 terminals: 12‑15 lb•in (1.4‑1.7 N•m); gROuND 

and 

NEuTRAL

  

terminals 14.2 lb•in (1,6  N•m).

  9.Tighten the grounding buss mounting screw to 4.4‑8.9 lb•in (0.5‑1.0 N•m).

10. Take caution that there are no loose wire strands. 

11. Reinstall cover. The handle must be in the “OFF” position. Start each of the four screws by hand to avoid 

cross threading. Tighten the four cover screws to 24 lb•in (2.7 N•m).  Make sure the sealing O‑rings are in 

place under the screw heads.

12. An additional DANgER label (D64558) has been supplied loose with this product as a convenience. Apply 

label to the outside of the front cover (see figure M‑11) if the product application does not pose the risk of the 

label being removed through cleaning, hose down or any other means.

13. Consult factory for auxiliary contact availability.

14. For all catalog suffix ending in –J or –H refer  to selector switch instruction below. See torque setting below. 

      http://literature.rockwellautomation.com/idc/groups/literature/documents/td/800-td008_-en-p.pdf
      http://literature.rockwellautomation.com/idc/groups/literature/documents/td/800-td009_-en-p.pdf
      800H selector switch terminal screw torque 6-8 lb-in (0.7-0.9 N-m) of torque. Wire gauge #18-10awg.

WIRING DIAGRAMS 

NOTE 

: “G” designates ground wire and yellow and green grounding buss.

30 A

600 VAC

1 HP

120 VAC 1Ø

3 HP

200-240 VAC 1Ø

5 HP

480 VAC 1Ø

7.5 HP 200-240 VAC 3Ø

15 HP

480 VAC 3Ø

15 HP

600 VAC 3Ø

NOTICE

: This manual motor con-

troller carries a maximum rating of:

15

A

B

C

Power

in

Power

out

D

B

125 VAC, 1Ø

240 VAC, 1Ø

240 VAC, 1Ø

480 VAC, 1Ø

600 VAC, 1Ø

240 VAC, 3Ø

480 VAC, 3Ø

600 VAC, 3Ø

125/240 VAC, 1Ø

120/208 VAC, 3ØY 

240/480 VAC, 3ØY 

347/600 VAC, 3ØY

Fig. M-5

Fig. M-3

Fig. M-7

Fig. M-8

Fig. M-9

11

12

4

14

10

Fig. M-6

Fig. M-4

6

8

5

9

14

13

Отзывы: