Huazheng HZBB-10S Скачать руководство пользователя страница 5

2

√1 print user manual

√1 copy of certificate and factory test repor

t

IV.Functional Characteristics

Lithium battery power supply or 100-240V AC power supply is self-adaptive.

After one charge, more than 100 transformers can be continuously tested in

the ratio group. The test process is simple and convenient.

It has the function of blind measurement, that is, to perform variable ratio

and group test when there is no connection between high and low voltage.

Based on the test of conventional transformer, Z-type transformer and PT

sample, the polarity test function of CT variable ratio is added, and the

application field is wider

Wide range and high accuracy, the variable ratio measurement range can

reach 10,000, and the test accuracy can be guaranteed 0.3% when the

maximum value is 10,000.

It has perfect protection functions such as reverse connection protection

and output short circuit protection.

5.6-inch super industrial high-brightness color LCD screen, still visible

under strong sunlight.

equipped with external printer, facilitate data printing

It can be stored locally and on USB memory.

V.Technical Indicators

Range

0.9

10000

Accuracy

±

Reading×0.1%+2 words

)(

≤500

±

Reading×0.2%+2 words

)(

>500≤3000

±

Reading×0.3%+2 words

)(

>3000

Resolution ration

0.9

9.9999

0.0001

10

99.999

0.001

Содержание HZBB-10S

Страница 1: ...HZBB 10S Portable Transformer Turns Ratio Tester Huazheng Electric Manufacturing Baoding Co Ltd...

Страница 2: ...manual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this...

Страница 3: ...aging Content 1 IV Functional Characteristics 2 V Technical Indicators 2 VI Adjust The Wristband 3 VII Battery Charging 3 VIII Tilt Hand held Tester 4 IX Product Appearance 4 X Operation Instructions...

Страница 4: ...e battery without authorization When the instrument or battery fails please return to the factory II Introduction Hand held transformer turn ratio tester is an innovative product with compact size han...

Страница 5: ...e polarity test function of CT variable ratio is added and the application field is wider Wide range and high accuracy the variable ratio measurement range can reach 10 000 and the test accuracy can b...

Страница 6: ...ure 10 50 Relative humidity 90 No dew VI Adjust The Wristband For better grip strip the belt and adjust the adhesive tape as shown in the following figure VII Battery Charging When the battery is low...

Страница 7: ...ld Tester In order to take the instrument or expose the side interface during operation the hand held tester can be tilted as shown in the figure below Lift the tilt seat and pull outward IX Product A...

Страница 8: ...yellow and green test lines are connected to single phase test Low voltage test terminal The yellow green and red three color junction bases correspond to the three phase of a B and C respectively an...

Страница 9: ...ted to the high voltage end of the tested product and the yellow and green test clamps of the black test line at the low voltage test end are connected to the low voltage end of the tested product Sin...

Страница 10: ...of printer paper tear the teeth out a little bit Close the cover and press the print head to the print head Press the print head back to the print head with a bit of force Operation instruction After...

Страница 11: ...e of the instrument Need a password operation it is not open to the user 5 SV Display software current version number HV Display hardware current version number The function and operation of are descr...

Страница 12: ...e connection mode and connection group of the tested products Group When the user chooses the known connection mode the measurement and display of the instrument are based on the user s input When the...

Страница 13: ...strument detects short circuit high and low voltage reverse connection fault the display screen will pop up the fault alarm box and stop measuring The three phase ratio test results screen is shown be...

Страница 14: ...ing according to the high side pressure regulating design is to assume that one point as the highest voltage range if the voltage reverse design or tap changer in low voltage side of transformer displ...

Страница 15: ...12 XII Packing List No Item Qty 1 Main engine 1 2 Red test line 1 3 Black test line 1 4 Print paper 2 5 Power line 1...