Huazheng Electric Manufacturing HZ-600C Скачать руководство пользователя страница 11

8

B

Status Display Area

The status display area displays working status of the current equipment.

C

Operating Zone

There are two keys in the operating area, start

and stop

that display in turn according to

service status, i.e. “start” displays under stop status and “stop” under start status.

There is a current status display label under the key to display current status of the tester:

“Offline status”: computer is working under off-line status, when only data reading and printing

functions are available.

“Equipment connected”: computer is connected with equipment and testing is possible.

“Equipment disconnected”: computer is disconnected with equipment and testing is impossible,

generally requiring reconnection and restart of software.

D

Test Parameter Setting Area

Area D displays parameter setting window that is used for setting of test parameters, including

winding wiring method, category and number of the winding to be tested, scan stop frequency, etc.

E

Curve Description Area

Area E displays description information of the current curve. The label in a color contains description

information of its corresponding curve in the same color.

F

Data Selection Area

What locates at the top right corner (F) is data selection area. Test data applies hierarchical

management, where the first grade is name of substation, the second grade name of transformer, the
third grade category and number of transformer winding and the last grade existing data. Data name is
displayed in the manner of “data type @ test time”. Data displayed in the part matches with content of
the label in area (A). When “amplitude-frequency curve” is displayed, the data selection area displays
test result of the amplitude-frequency curve and when “phase-frequency curve” is displayed, the data
selection area displays test result of the phase-frequency curve.

When “amplitude-frequency curve” or “phase-frequency curve” is displayed, the test result is

displayed in area A when relevant data is clicked.

G

Function Key Area

Keys in the function key area (G) will switch automatically and display dynamically based on the use

function.

Содержание HZ-600C

Страница 1: ...HZ 600C Transformer Winding Deformation Tester USER MANUAL Huazheng Electric Manufacturing Baoding Co Ltd...

Страница 2: ...anual and operate and maintain the instrument according to the manual to prolong its service life Just a light press the test will be completed automatically is the operating characteristics of this i...

Страница 3: ...ntroduction 3 Part I Simple Operation Flow of System 4 Part II Preparation 5 Part III Test Wiring 5 Part IV System Test 7 Part V Tester Maintenance 13 Annex Instructions for Installation of Transforme...

Страница 4: ...sition and every wiring terminal is normal Winding deformation test must be carried out on the conditions that all leads of the transformer including overhead line enclosed busbar and cable are discon...

Страница 5: ...t water proof Put the tester into its packing case when not used and keep the packing case level The scrapped equipment must be handled according to requirements of national laws and regulations or ha...

Страница 6: ...haracteristics of transformer windings are measured with frequency sweep method Deformations of windings such as distortion swell or displacement of 6kV and above transformer are measured by detecting...

Страница 7: ...each curve and diagnose winding deformations to provide the reference diagnosis conclusion Software management function is powerful that takes into full account of site use demand Measuring data is au...

Страница 8: ...ic operations of computer and Windows operating system are not contained in the operation instructions Please refer to relevant computer books Note basic operations of Windows operating system involve...

Страница 9: ...during transformer winding deformation test is as shown in Figure 2 3 2 Winding Wiring Mode Figure 2 Wiring type Comnect the terminal on the front panel to testee the code of the terminal is acrrodin...

Страница 10: ...oordinate and dB value with Y coordinate amplitude frequency test or angle value phase frequency test The label below consists of Curve type label to mark the current display is amplitude frequency cu...

Страница 11: ...uency etc E Curve Description Area Area E displays description information of the current curve The label in a color contains description information of its corresponding curve in the same color F Dat...

Страница 12: ...sktop The system will flash through the welcome interface and then enter the test interface The system will have following dialogue box if equipment is not connected Occurrence of the above dialogue b...

Страница 13: ...ction menu pop up The information setting window as shown in the figure below will pop up when setting is selected where you may adjust the default scanning information and restart the software after...

Страница 14: ...st curve display area A is double clicked in the test process which contains waveform display input voltage peak value red response voltage peak value yellow amplification factor and X coordinate time...

Страница 15: ...equiring analysis you may right click clear curve on the curve description information E so that the curve will be removed out of the analysis list automatically Curves in area E are automatically div...

Страница 16: ...low humidity and protect it against entry of dirt and dust Put the tester into its packing case when not used and keep the packing case level 5 2 Senior Maintenance To be proceeded by professional tec...

Страница 17: ...der and delete the entire folder if the computer is not installed before directly enter step 2 2 Open the installation file package double click setup exe file and open the installation file 3 Click i...

Страница 18: ...is clicked the drive installation interface will display Select Install and turn to the next step installation 6 Click Confirm and then click to quit instlalation 7 Select Confirm and turn to the next...

Страница 19: ...y communication module installation program of which the interface is as shown below If the system is not installed with the software before select Next Step until installation is completed If the sys...

Страница 20: ...tion interface closes automatically indicating the system installation is completed At the time the executive file icon will occur on the desktop as shown below Installation of the test software compl...

Отзывы: