Huayu HYL-3000 Скачать руководство пользователя страница 3

Information on this Manual

Validity

This manual is valid for the following devices:HYL-3000/HYL-4000 /HYL-5000

Scope

This manual provides  the installation, operation and troubleshooting of this unit, please read this manual 

carefully before installations and operations.

Target Group

For qualified persons and end users. Qualified persons and end users must have the following skills:

Knowledge about this unit operation

Training in  deal with the security issues associated with installations and electrical safety

Training in the installation and commissioning of electrical devices and installations

Knowledge of the applicable local standards and directives

Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual 

for future reference.

All the operation and connection need to be operated by qualified persons.

Before using the unit, read all instructions and cautionary marking on the unit. Any  damage caused by 

inappropriate operation is not warranted by huayu .

All the electrical installation must comply with the local electrical safety standards.

Do not disassemble the unit. Take it to a qualified service center when service or repair is required, 

incorrect re-assembly may result in a risk of electric shock or fire. Do not open inverter cover or change 

any components without huayu's authorization, otherwise the warranty commitment for the inverter 

will be invalid.

To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning, 

turning off the unit will not reduce this risk.

CAUTION-To reduce risk of injury, charge only deep-cycle lead-acid type rechargeable batteries and 

lithium batteries, other types of batteries may burst, causing personal injury and damage.

NEVER charge a frozen battery.

For optimum operation of this unit, please follow required spec to select appropriate cable size and breaker.

Please strictly follow installation procedure when you want to disconnect AC or DC terminals, please refer 

to INSTALLATION section of this manual for the details.

GROUNDING INSTRUCTIONS -This unit should be connected to a permanent grounded wiring system, 

be sure to comply with local requirements and regulation to install this inverter.

NEVER cause AC output and DC input short circuited. Do not connect to the mains when 
DC input short circuits.

1.   Brief Introduction

1.1  Features of the Inverter

HYL series is a multifunctional, high frequency pure sine wave entry-level hybrid solar inverter, features:

Applicable for pure off grid/ backup power / self-consumption / on grid situation

Integrated with 2 MPPT solar charge controllers, MPPT ranges 120V~385V

Rated power 5KW, power factor 1

Be able to run with or without battery in ongrid and offgrid mode

With separated generator input interface, able to control generator remotely

Solar and utility grid can power loads at the same time

With integrated advanced parallel function, up to 10pcs max paralleling 

Support CAN/RS485 for Li-ion battery BMS communication

WIFI/ GPRS remote monitoring , setting and firmware update, support website, free IOS/Android APP

LOGIN

Solar Panel

Utility Grid

Generator

Battery

Wifi / 4G

Internet

Huayu View

Huayu Server

Home
Loads

01

02

Содержание HYL-3000

Страница 1: ...USER MANUAL Huayu Entry Level Hybrid Solar Inverter HYL 3000 HYL 4000 HYL 5000 www huayu solar com info huayu energy com Huayu Ningbo New Energy Technologies Co Ltd For Our Home Energy Independence...

Страница 2: ...Connection 2 5 PV Connection 2 7 Dry Contact Signal Control 2 9 Power ON OFF 4 LCD Display and Settings 2 8 Parallel Function 5 Monitor System 3 Working Modes 7 Trouble Shooting Error List 6 Specifica...

Страница 3: ...any maintenance or cleaning turning off the unit will not reduce this risk CAUTION To reduce risk of injury charge only deep cycle lead acid type rechargeable batteries and lithium batteries other ty...

Страница 4: ...if not installed immediately refer to below figure a The inverter and its components must be stored in its original packaging b The storage temperature should be within 25 60 and humidity within 0 85...

Страница 5: ...AC output GEN cable size for each inverter Model Gauge Cable mm2 Torque Value 3 PV Connection Please install separately a DC circuit breaker between inverter and PV modules The recommended of DC brea...

Страница 6: ...tery configuration in order to communicate with battery BMS you should set the battery type to Li ion in Program 03 by LCD and choose the right battery brand for details please check the LCD setting c...

Страница 7: ...tput Connection CAUTION There are two terminal blocks with IN and OUT markings Please do NOT mis connect input and output connectors Please follow below steps to implement AC input output connection 1...

Страница 8: ...r battery charging reaches floating stage Battery voltage Low DC warning voltage Battery voltage Setting value or battery charging reaches floating stage NO2 COM2 NC2 COM2 Close Open Close Open Close...

Страница 9: ...m For more detailed guidance for paralleling system please visit https www huayu solar com download And download the guidance Monitor Data Overview Maintain Stations Overview Station Name Serial numbe...

Страница 10: ...st power from PV can feed in Grid PV BAT Grid On PV Battery power the load and the AC can power the load if PV Battery power not enough PV Grid On PV power the load the rest power feed in Grid PV Char...

Страница 11: ...Mode 1 charge first AC charge battery if solar power is not enough to charge battery and the battery voltage SOC is lower than AC start charge voltage SOC the AC will stop charging when the battery V...

Страница 12: ...n AC Charge Start Battery SOC and will stop when Voltage is higher than AC Charge End Battery SOC And battery will not discharge during the setting time 19 20 PV AC Take Load Jointly Export to Grid En...

Страница 13: ...V voltage Floating charging voltage Cut off voltage Discharge end voltage And display the voltage SOC and power in turns of period of 1 seconds System working status setting code There are three type...

Страница 14: ...dc DC source input There are four buttons on the LCD Step for settings by the display Step1 After touching enter button for about 2 seconds the unit will enter setting mode The setting icon and index...

Страница 15: ...Battery Step1 Choose battery type first when Li ion flashing select Enter to choose Li ion battery Step2 Choose battery brand 0 Standard Battery 2 Pylon Battery 6 Huayu Protocol Battery 8 Dyness Batte...

Страница 16: ...ource AC Input to take Load time setting Setting time of 1 start Range 00 00 23 59 Default 00 00 00 00 Setting time of 1 end Range 00 00 23 59 Default 00 00 00 00 Similar to set time 2 and time3 15 st...

Страница 17: ...Enable 16 19 20 PV Off Grid enable disable Setting Range PV Off Grid Enable default PV Off Grid Disable Green Function enable disable Setting Range Green Function Disable default Green Function Enable...

Страница 18: ...P store Scan two code bar to download the APP INVERTER MODEL HYL 5000 HYL 4000 HYL 3000 Input Voltage Waveform Sinusoidal utility or generator Nominal Input Voltage 230Vac Low Loss Voltage 170Vac 7V U...

Страница 19: ...ow DC Warning Voltage Different load 2V load 20 20 load 50 load 50 42 0Vdc Settable Cut off Voltage load 20 1 2V Cut off Voltage load 20 3 6V Low DC Warning Return SOC 15 SOC Grid off settable Low DC...

Страница 20: ...part there should be one master in the system CAN communication error in parallel system Check parallel setting for master Slave part there should be one master in the system No master in parallel sys...

Отзывы: