Figure 5-26 Connecting a PGND cable
NO TICE
The OT terminal may rotate and result in device damage. Make sure that it is
independent of the adjacent metal mechanical part or other terminals.
----End
Follow-up Procedure
Verify the following after the cabling is complete:
●
The PGND cable is securely connected to the ground terminal.
●
The electrical resistance between the ground terminal and ground point is less
than 0.1 ohm on a multimeter.
5.4.3 Installing a Hard Disk
This section describes how to install a hard disk units for the first time to avoid
hard disk damage.
Precautions
Precautions for the use of hard disks
●
Use Huawei hard disks. The system cannot recognize the hard disks provided
by other vendors.