Figure A-1
PGND cable
shows the appearance of the OT bare crimp terminal.
Figure A-2
OT bare crimp terminal
Installation
1.
Connect the OT bare crimp terminal at one end of the PGND cable to the connection
hole of the USG, with the conducting wire upward, as shown in A of
Figure A-3
Installing the OT bare crimp terminal
A
B
2.
Select a matching screw for the screw jack and turn the screw in clockwise direction to
fasten it. For reliable connection, make sure that at least two full threads match each
other.
3.
Pull the power cable gently to verify that it is well connected.
4.
Connect the other end of the PGND cable to the ground port of the equipment room or
cabinet.
HUAWEI USG6000 Series
Hardware Guide
A Appendix
Issue 08 (2017-06-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
372