U8950 Maintenance Guide V1.0
9 Maintenance Records During Verification
2012-10-22
Huawei Proprietary and Confidential
32
9
Maintenance Records During Verification
9.1 Maintenance Records on Each Stage
Stage
Station of Fault
Faulty Item
Symptom
Solution
V3
Board upgrade
The upgrade
failed at 4%.
The data was lost.
The board was formatted and
reloaded and the test then passed.
V3
Loading
Poor loading
The flash chip was
poorly soldered.
The software was reloaded and no
interface was detected. The test
passed after the flash chip was
heated and re-soldered.
V3
Loading
Poor loading
The data was lost.
The board was formatted and
reloaded and the test then passed.
V3
CT
MMI06A
vibrator
malfunction
The vibrator was
faulty.
The faulty product was retained, as
required by the R&D department, for
analysis by the vendor.
V3
MMI
MMI06A
vibrator
malfunction
The FPC and BTB
connector were not
fit in place.
The BTB connector was refitted.
V3
MMI
MMI06A
vibrator
malfunction
The FPC BTB
connecting to the
antenna board was
bridged, resulting in
the grounding of
VIB_DRV_N. The
vibrator started
vibrating once the
battery was loaded.
The vibrator was re-soldered.
V3
MMI
MMI05C
touchscreen
malfunction
The chip on the
touchscreen was
damaged.
The touchscreen was replaced.