SUN2000-(36KTL,42KTL)
User Manual
10 Technical Specifications
Issue Draft A (2016-05-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
92
Item
SUN2000-36KTL
SUN2000-42KTL
Note b: If the rated output voltage of the SUN2000-36KTL is 380 V AC or 400 V AC, the
rated input voltage is 620 V. If the rated output voltage is 480 V, the rated input voltage is
720 V.
Output
Item
SUN2000-36KTL
SUN2000-42KTL
Rated output power
36,000 W
42,000 W
Maximum apparent power
40,000 VA
47,000 VA
Maximum AC output power
(cos φ = 1)
40,000 W (can be set to
36,000 W)
47,000 W (can be set to
42,000 W)
Rated output voltage
220 V AC/380 V AC, 230 V
AC/400 V AC,
3W+(N)
c
+PE; 277 V
AC/480 V AC, 3W+PE
277 V/480 V, 3W+PE
Adapted power grid
frequency
50 Hz/60 Hz
Maximum output current
60.8 A
d
/57.8 A
e
/48.2 A
f
56.6 A
Power factor
0.8 leading ... 0.8 lagging
Total harmonic distortion
(THD)
< 3%
Note c: Choose whether to connect the neutral wire to the SUN2000-36KTL based on the
application scenario. When the SUN2000-36KTL is used in a low-voltage scenario without
the neutral wire, you need to set
Output mode
to
Three-phase, three-wire without N line
on the SUN2000 app, SmartLogger, or NetEco.
Note d: If the rated output voltage of the SUN2000-36KTL is 380 V AC, the maximum
output current is 60.8 A.
Note e: If the rated output voltage of the SUN2000-36KTL is 400 V AC, the maximum
output current is 57.8 A.
Note f: If the rated output voltage of the SUN2000-36KTL is 480 V AC, the maximum
output current is 48.2 A.
Protection
Item
SUN2000-36KTL
SUN2000-42KTL
Input DC switch
Supported
Standalone operating
detection (anti-islanding
protection)
Supported