Since the output of the PV string connected to the solar inverter cannot be grounded,
ensure that the PV module output is well insulated to ground.
During the installation of PV strings and the solar inverter, the positive or negative
terminals of PV strings may be short-circuited to ground if the power cable is not properly
installed or routed. In this case, an AC or DC short circuit may occur and damage the solar
inverter. The caused device damage is not covered under any warranty.
The solar inverter supports Y type terminals.
Context
Figure 5-9
DC input terminals
(1) Terminals of DC input 1
(2) Terminals of DC input 2
Procedure
Step 1
Assemble positive and negative connectors.
Use the positive and negative metal terminals and DC connectors supplied with the solar
inverter. Using incompatible positive and negative metal terminals and DC connectors may
result in serious consequences. The caused device damage is not covered under any warranty
or service agreement.