3 Storage
Issue 03 (2020-06-03)
Copyright © Huawei Technologies Co., Ltd.
15
3
Storage
The following requirements should be met if the solar inverter is not put into use directly:
Do not unpack the solar inverter.
Keep the storage temperature at –40°C to +70°C and the humidity at 5%–95% RH.
The solar inverter should be stored in a clean and dry place and be protected from dust
and water vapor corrosion.
A maximum of 10 solar inverters can be stacked. To avoid personal injury or device
damage, stack solar inverters with caution to prevent them from falling over.
Regular inspection is required during the storage. Replace the packing materials that are
damaged by insects or rodents in a timely manner.
If the solar inverter has been stored for a long time, inspections and tests should be
conducted by qualified personnel before it is put into use.