SUN2000-(30KTL-A, 33KTL, 40KTL)
User Manual
5 Electrical Connections
Issue 04 (2016-06-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
53
Figure 5-15
shows the DC terminals at the bottom of the SUN2000.
Table 5-2
describes
the requirements for DC terminal selection.
Figure 5-15
DC terminals
Table 5-2
DC terminal selection requirements
Number of Inputs SUN2000
1
Connected to any one route
2
Connected to routes 1 and 3
3
Connected to routes 1, 3, and 5
4
Connected to routes 1, 2, 3, and 5
5
Connected to routes 1, 2, 3, 4, and 5
6
Connected to routes 1, 2, 3, 4, 5, and 6
DC input cable specifications
Table 5-3
lists the recommended DC input cable specifications.
Table 5-3
Recommended DC input cable specifications
Cable Type
Cross-sectional Area (mm
2
)
Cable Outer
Diameter (mm)
Range
Recommended
Value
Common PV cables in
the industry (model:
PV1-F)
4.0–6.0 (or 12–10
AWG)
4.0 (or 12 AWG)
4.5–7.8