SW2-8
SW2-7
Speed
Adjustment
Mode
Speed Adjustment Policy
Remar
ks
OFF
OFF
Stop fan
rotating and
measure the
temperature at
the air intake
vent
Policy 4
l
If the temperature is lower than 15°C,
the fans stop rotating.
l
If the temperature ranges from 15°C to
45°C, the fans rotate at 50% of the full
speed.
l
If the temperature ranges from 45°C to
65°C, the fans rotate at 50% to 100%
of the full speed.
l
If the temperature is higher than 65°C,
the fans rotate at full speed.
-
Procedure
Step 1
Loosen the screws on the front panel of the fan tray anticlockwise by using the Phillips
screwdriver, as shown in (1) of
.
Figure 1-7
Removing/Inserting the fan tray
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
1 Commissioning
Issue 01 (2014-04-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15