background image

 

 

 

 

 

 

 

 

 

 

HUAWEI SE2900 Session Border Controller

 

V300R002C10

 

Hardware Description

 

 

 

Issue 

01

 

Date 

2016-01-15

 

HUAWEI TECHNOLOGIES CO., LTD. 

Содержание SE2900

Страница 1: ...HUAWEI SE2900 Session Border Controller V300R002C10 Hardware Description Issue 01 Date 2016 01 15 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...e customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject...

Страница 3: ...k 17 1 4 1 AC PSU 24 1 4 2 Fan Tray 28 1 5 F8002 Subrack System Topology Structure 30 1 5 1 CAN Bus 30 1 5 2 Base Topology Structure 31 1 5 3 eFabric Topology Structure 32 1 6 F8002 Subrack System Monitoring 33 1 6 1 Power Module Monitoring 33 1 6 2 Fan Tray Monitoring 33 1 7 MXU 34 1 7 1 MXUA0 34 1 8 SPU 45 1 8 1 SPUA0 45 1 8 2 SPUA1 53 1 8 3 SPUZ0 61 1 9 VPU 69 1 9 1 VPUA0 69 1 9 2 VPUA1 77 1 10...

Страница 4: ...r and PGND Cables to a Subrack 101 3 1 2 Power Cables of the Alarm Box 104 3 2 Signaling Cables 105 3 2 1 Ethernet Cable 105 3 2 2 LC PC LC PC Multi Mode Optical Cable 108 3 2 3 DLC PC DLC PC Multi Mode Optical Cable 109 3 2 4 LC PC LC PC Single Mode Optical Cable 110 3 2 5 MPO PC MPO PC Multi Mode Optical Cable 112 3 2 6 High Density Cable 113 3 2 7 DB9 RJ45 Serial Cable 115 ...

Страница 5: ... Confidential Copyright Huawei Technologies Co Ltd 1 1 Service Processing Device About This Chapter 1 1 Subrack Datasheet 1 2 Subrack Classification and Numbering Rules 1 3 F8002 DC Subrack 1 4 F8002 AC Subrack 1 5 F8002 Subrack System Topology Structure 1 6 F8002 Subrack System Monitoring 1 7 MXU 1 8 SPU 1 9 VPU 1 10 Filler Panel ...

Страница 6: ...AWEI SE2900 Session Border Controller Hardware Description 1 Service Processing Device Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 2 1 1 Subrack Datasheet ...

Страница 7: ...HUAWEI SE2900 Session Border Controller Hardware Description 1 Service Processing Device Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 3 ...

Страница 8: ...HUAWEI SE2900 Session Border Controller Hardware Description 1 Service Processing Device Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 4 ...

Страница 9: ...rack from the bottom and is numbered 0 If there are multiple cabinets the subracks are numbered in ascending order based on the cabinet numbers Figure 1 1 illustrates how subracks are numbered Figure 1 1 Subrack numbering rules Figure 1 1 uses a cabinet configured with more than two subracks as an example Number subracks based to the subrack numbering rule depending on the actual situation Subrack...

Страница 10: ...ons Function Description Power supply Two power entry modules PEMs are configured in 1 1 redundancy mode Each PEM supplies DC power to the entire subrack through the backplane Data transmission The F8002 subrack provides data transmission channels Heat dissipation Two fan trays are configured to dissipate heat for the subrack Subrack identification Each F8002 subrack has a unique number If the sub...

Страница 11: ... Huawei Technologies Co Ltd 7 Figure 1 3 F8002 subrack unit mm Each F8002 subrack provides six slots for installing the multi function switch units MXUs and service boards Figure 1 4 shows the slot positions of the F8002 subrack Figure 1 4 F8002 subrack slot positions The F8002 subrack provides Slots 2 and 5 for MXUs Slots 1 3 4 and 6 for service boards ...

Страница 12: ...on Figure 1 6 shows the rear view of an F8002 subrack Figure 1 6 Rear view of an F8002 subrack Table 1 2 describes the components of the F8002 subrack Table 1 2 F8002 subrack components Componen t Quantit y Description MXU 2 The MXUs implement operation maintenance and management of the system Two MXUs are installed in slots 2 and 5 to work in active standby mode Service boards 4 The service board...

Страница 13: ...front of the subrack and exhaust warm air from the rear of the subrack Figure 1 7 shows the air flows Ground point 2 The F8002 subrack provides two ground points If the subrack is used in North America connect both ground points If the subrack is used in other regions only connect one of the ground points Electrostatic discharge ESD jack 1 The F8002 subrack provides one ESD jack Figure 1 7 Heat di...

Страница 14: ... work in active standby mode Only the active MXU executes management tasks The MXUs also manage the two fan trays through the RS485 bus and the two PEMs through the Inter integrated circuit I2C bus The service data and signaling data from a service board is forwarded in eFabric channels to the MXUs through the backplane The MXUs then forward the data to another service board The management data fr...

Страница 15: ...W x D 130 5 mm x 442 0 mm x 675 0 mm 5 14 in x 17 40 in x 26 57 in Weight of an empty subrack 20 8 kg 45 86 lb NOTE An empty subrack is equipped with two fan trays and two PEMs Weight of a fully loaded subrack 47 8 kg 105 38 lb NOTE A fully loaded subrack is equipped with two fan trays two PEMs two MXUA0s and four SPUA0s Power supply Rated input voltage 48 V DC to 60 V DC Operating voltage 40 V DC...

Страница 16: ...than 15 days 1 3 1 PEM Functions Table 1 5 describes the functions of the power entry module PEM Table 1 5 PEM functions Function Description Power supply Supplies power to devices in the subrack Supports wide input voltage range Power distribution monitoring Detects the installation status and type of PEMs Provides the indicators on the panel to indicate PEM status Detects the voltage and power o...

Страница 17: ...cessing Device Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 13 Figure 1 10 PEM Figure 1 11 shows the PEM panel Figure 1 11 PEM panel 1 STATUS indicator 2 Power input terminal RTN 3 Power input terminal protective cover 4 Handle ...

Страница 18: ...wer supply Green The PEM is operating properly Red The power supply is abnormal The surge protection circuit is faulty The circuit breaker is faulty Technical Specifications Table 1 7 lists the technical specifications of the PEM Table 1 7 PEM technical specifications Item Specifications Mechanical specificatio ns Dimensions H x W x D 122 5 mm x 65 0 mm x 122 7 mm 4 82 in x 2 60 in x 4 83 in Weigh...

Страница 19: ...unction Description Heat dissipation The fan trays draw in cool air from the front of the subrack and exhaust warm air from the rear of the subrack Monitoring Fan monitoring boards are configured for fan trays to Provide ports for communicating with the switch boards Detect and report the fan operating status and speed values Control the health indicators on the fan trays Support fan blocking stat...

Страница 20: ...1 9 describes the indicator on the panel Table 1 9 Health indicator on the fan tray Silk Screen Meaning State State Description None Health indicator Off The fan monitoring module is not powered on Blinking green Blinking at 0 5 Hz The fan tray is operating properly and the communication is normal Blinking at 4 Hz The fan tray is operating properly but the communication is abnormal Steady orange T...

Страница 21: ...nvironme ntal specificatio ns Temperature Long term operating temperature 0 C to 70 C 32 F to 158 F Storage temperature 40 C to 70 C 40 F to 158 F Noise 66 dBA 1 4 F8002 AC Subrack Functions Table 1 11 describes the functions of the F8002 subrack Table 1 11 F8002 subrack functions Function Description Power supply Two AC power supply units PSUs are configured in 1 1 redundancy mode Each AC PSU sup...

Страница 22: ...uawei Technologies Co Ltd 18 Appearance Figure 1 13 shows an F8002 subrack Figure 1 13 F8002 subrack unit mm Each F8002 subrack provides six front slots and four rear slots The front slots are installed with the multi function switch units MXUs and service boards The rear slots are installed with AC PSUs and fan modules Figure 1 14 shows the slot positions ...

Страница 23: ...d 19 Figure 1 14 F8002 subrack slot positions The F8002 subrack provides Slots 2 and 5 for MXUs Slots 1 3 4 and 6 for service boards PSU 1 and PSU 2 for AC PSUs Fan 1 and Fan 2 for fan trays Figure 1 15 shows the front view of an F8002 subrack in full configuration Figure 1 15 Front view of an F8002 subrack in full configuration Figure 1 16 shows the rear view of an F8002 subrack ...

Страница 24: ...standby mode AC PSU 2 Two AC PSUs are configured in 1 1 redundancy mode If one AC PSU is faulty the power supply to the subrack is not affected Fan tray 2 Two fan trays are configured to perform heat dissipation for the components in the subrack Figure 1 17 shows the air flows Heat dissipation of the subrack The fans draw in cool air from the front of the subrack and exhaust warm air from the rear...

Страница 25: ...tial Copyright Huawei Technologies Co Ltd 21 Figure 1 17 Heat dissipation in the subrack Figure 1 18 shows the power supply mode of the F8002 subrack Each AC PSU supplies power to all slots and fan trays in the subrack Figure 1 18 F8002 subrack power supply mode Logical Structure Figure 1 19 shows the logical structure of the F8002 subrack ...

Страница 26: ...ter integrated circuit I2C bus The service data and signaling data from a service board is forwarded in eFabric channels to the MXUs through the backplane The MXUs then forward the data to another service board The management data from a service board is forwarded in Base channels to the MXUs through the backplane The MXUs then forward the data to another service board Hardware and Software Compat...

Страница 27: ...y Rated input voltage AC 200 V to 240 V High voltage DC 240 V Maximum input voltage AC 176 V to 264 V High voltage DC 192 V to 288 V Total power inputs Two Rated input current 10 A power input Power rating 2000 W The rated power of each AC PSU is 2000 W NOTE The subrack is configured with two AC PSUs in 1 1 redundancy mode Environme ntal specificatio ns Temperature Operating temperature 0 C to 40 ...

Страница 28: ...n Power distribution monitoring Detects the AC PSU installation status AC PSU type and power input Provides indicators on the panel to indicate AC PSU status Supports queries on input output voltage and current Supports queries on input power and maximum output power Supports queries on the electronic label temperature and version of the AC PSUs Detects the fan fault of the AC PSUs Protection Supp...

Страница 29: ...ion Border Controller Hardware Description 1 Service Processing Device Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 25 Figure 1 20 AC PSU Figure 1 21 shows the AC PSU panel ...

Страница 30: ...ive screw Indicators Table 1 16 describes the STATUS indicator on the AC PSU panel Table 1 16 STATUS indicator on theAC PSU panel Silk Screen Meaning State State Description STATUS Status indicator Off There is no power supply Steady green The AC PSU is operating properly Blinking green at 0 5 Hz The AC PSU is in hibernation mode and is supplying no power Blinking green at 4 Hz The AC PSU software...

Страница 31: ...the AC PSU Table 1 17 AC PSU technical specifications Item Specifications Mechanical specificatio ns Dimensions H x W x D 120 0 mm x 79 0 mm x 122 0 mm 4 72 in x 3 11 in x 4 80 in Weight 1 36 kg 3 00 lb Voltage and current Rated input voltage AC 200 V to 240 V High voltage DC 240 V Maximum input voltage AC 176 V to 264 V High voltage DC 192 V to 288 V Rated input current 10 A Operating frequency A...

Страница 32: ...g Fan monitoring boards are configured for fan trays to Provide ports for communicating with the switch boards Detect and report the fan operating status and speed values Control the health indicators on the fan trays Support fan blocking status detection and reports fan alarms Support online software upgrades and log uploads Monitor and report the fan temperature Detect the fan tray installation ...

Страница 33: ... 19 describes the indicator on the panel Table 1 19 Health indicator on the fan tray Silk Screen Meaning State State Description None Health indicator Off The fan monitoring module is not powered on Blinking green Blinking at 0 5 Hz The fan tray is operating properly and the communication is normal Blinking at 4 Hz The fan tray is operating properly but the communication is abnormal Steady orange ...

Страница 34: ...0 in x 5 16 in x 4 91 in Weight 1 7 kg 3 75 lb Electrical specificatio ns Total power inputs Two power inputs are provided by the backplane in the subrack Maximum power consumption 140 W Typical power consumption 20 W Environme ntal specificatio ns Temperature Long term operating temperature 0 C to 70 C 32 F to 158 F Storage temperature 40 C to 70 C 40 F to 158 F Noise 66 dBA 1 5 F8002 Subrack Sys...

Страница 35: ...oards are the managed units in the subrack The management and managed units communicate with each other Each board is connected to the CAN bus through two independent channels If one channel is unavailable the other channel is used to ensure uninterrupted communication 1 5 2 Base Topology Structure Functions The Base plane serves as the management and control plane in the subrack It provides chann...

Страница 36: ...nication reliability Service processing is not affected if one Base channel becomes unavailable for any service board 1 5 3 eFabric Topology Structure Functions The enhanced Fabric eFabric plane transmits service data in the system Figure 1 25 shows the eFabric plane connections Figure 1 25 eFabric plane connections Topology The dual star topology is used for eFabric plane connections The eFabric ...

Страница 37: ...le monitoring system in the F8002 subrack Figure 1 26 Structure of the power module monitoring system in the F8002 subrack The BMCs in power modules communicate with the shelf management modules SMMs in MXUs to implement monitoring of the following information about power modules Power module installation status type and version Electronic label Surge protection Circuit breaker status Power input ...

Страница 38: ...us Detects the fan tray slot numbers 1 7 MXU The multi function switch units MXUs exchange service plane data and provide ports for eFabric interface cascading 1 7 1 MXUA0 Functions Table 1 21 describes the functions of the MXUA0 Table 1 21 Functions Function Description Operation and maintenance The general processing card GPC on the MXUA0 implements subrack configuration and maintenance monitors...

Страница 39: ...s 80 Gbit s bandwidth for each service slot There are Base and eFabric plane interconnect channels between MXUA0s Device manageme nt The SMM provides the following device management functions Board management Detects the board temperature voltage and power implements power control manages board hot swap and reset and monitors the operating and health status Supports out of band and remote manageme...

Страница 40: ...oller Hardware Description 1 Service Processing Device Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 36 Figure 1 28 Appearance unit mm Figure 1 29 shows the hardware structure of the MXUA0 ...

Страница 41: ...tial Copyright Huawei Technologies Co Ltd 37 Figure 1 29 Hardware structure Table 1 22 describes the components of the MXUA0 Table 1 22 Components N o Compon ent Quantity Description 1 Hard disk 1 One 2 5 inch 600 GB SAS hard disk is configured before delivery 2 Dual in line memory module DIMM 1 One 8 GB DIMM is used to provide 8 GB memory ...

Страница 42: ...ure 1 30 shows the MXUA0 panel Figure 1 30 Panel 1 LAN0 2 LAN1 3 RS232 4 RS485 5 eFabric LAN0 6 eFabric LAN1 7 Subrack number indicators 8 Base LAN0 9 Base LAN1 10 HLY indicator 11 ACT indicator 12 Ejector levers 13 OFL indicator button 14 DIP button 15 eFabric LAN0 LAN1 indicators 16 HD ALM indicator 17 LAN1 LINK indicator 18 LAN1 ACT indicator 19 LAN0 LINK indicator 20 LAN0 ACT indicator Interfa...

Страница 43: ...85 port eFabric LAN0 LAN1 Cascading port for the eFabric plane Quad Small Form factor Pluggable Plus QSFP 40GBASE SR4 Base LAN0 LAN1 Cascading port of the Base plane RJ45 10 100 1000BASE T Indicators Figure 1 32 shows the indicators and buttons on the MXUA0 Table 1 24 describes the indicators and buttons Figure 1 32 Indicators and buttons Table 1 24 Description of indicators and buttons Silk Scre ...

Страница 44: ... 0 5 seconds To safely power off the GPC hold down this button for 6 seconds until the OFL indicator is blinking blue When the OFL indicator is blinking blue the GPC is in the graceful power off state When the OFL indicator is steady blue the GPC is powered off To forcibly power off the GPC hold down this button for 6 seconds when the GPC is in the graceful power off state DIP indic ator Subr ack ...

Страница 45: ...rs exit the setting mode without saving the settings Each time you press the DIP button the subrack number increases by 1 The subrack number restarts from 0 after it passes 7 ACT Networ k port indicat or Off The port is not sending or receiving data Blinking yellow The port is sending or receiving data LIN K Networ k port indicat or Green The link is connected Off The link is faulty or disconnecte...

Страница 46: ...e following ports Two GE ports One serial port for system commissioning One serial port for PDB monitoring Two ports for eFabric plane cascading Two ports for Base plane cascading The GPC implements configuration and maintenance monitors system status and collects performance statistics It also provides two GE ports for O M The SMM monitors the MXUA0 and the BMCs on service boards and performs sub...

Страница 47: ... Number of Base plane ports 11 Four GE ports connected to the service boards in the subrack through the backplane One GE port connected to the GPC of the MXU One GE port connected to the GPC of the other MXU in the subrack through the backplane One GE port connected to the CPU of the MXU One GE port connected to the CPU of the other MXU in the subrack through the backplane Two GE ports provided on...

Страница 48: ...itching capability 44 Gbit s for the Base plane Full duplex mode 480 Gbit s for the eFabric plane Full duplex mode Number of MAC addresses 32768 The ports support automatic learning of MAC addresses The MAC address table can contain a maximum of 32 768 MAC addresses Number of VLANs 4094 The VLANs comply with the 802 1Q standard Port binding 8 Port binding complies with the 802 3AD standard A maxim...

Страница 49: ...The service processing units SPUs implement service processing and board management 1 8 1 SPUA0 Functions Table 1 28 describes functions of the SPUA0 Table 1 28 Functions Function Description Service processing Uses one Intel Xeon full power 8 core Sandy Bridge EP CPU Provides four double data rate 3 DDR3 memory channels each for installing one 16 GB registered dual in line memory module RDIMM The...

Страница 50: ...I bus The BMC provides the following functions Manages the field replaceable unit FRU information sensor data records SDRs and system event logs SELs Detects the board temperature and voltage reports alarms and controls the power on power off hot swap and reset operations of the board Supports serial port redirection Loads board software online Hot swap The boards are hot swappable Appearance The ...

Страница 51: ...15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 47 Figure 1 35 Hardware structure Table 1 29 describes the components of the SPUA0 Table 1 29 Components No Compone nt Quantity Description 1 BMC 1 The BMC a processing module independent from the CPU implements board management and ...

Страница 52: ... 4 Cover 1 The metal cover is used to protect the components on the board and guide air flows 5 RDIMM 3 Three 16 GB RDIMMs are used to provide 48 GB memory NOTE The RDIMMs are installed close to CPU0 The three RDIMMs are installed in sockets J45 J46 and J7 as shown in Figure 1 35 6 Solid state drive SSD 1 The SSD stores the operating system OS and field programmable gate array FPGA files Figure 1 ...

Страница 53: ...P NOTE The ports can be set to the auto negotiation or forced mode 10G BASE R port 1 10GE or 1GE optical port port 2 10GE or 1GE optical port or electrical port port 3 10GE or 1GE optical port port 4 1GE optical port or electrical port SFP NOTE The ports can be set to the auto negotiation or forced mode 1000 BASE T port 5 1GE optical port port 6 1GE optical port or electrical port port 7 1GE optic...

Страница 54: ...linking at 4 Hz indicates a critical alarm UID Location indicator Off The indicator is used to locate a device to be operated You can customize the function of this indicator Steady green Blinki ng green OFL Offline indicator Off The board is operating properly Blinki ng blue The board is sending a request for power on or power off or the board is being powered on or off Steady blue The board is p...

Страница 55: ...is in the graceful power off state 0 to 7 Optical port indicator s Green off The link is faulty or disconnected Steady green The link is normal Yello w off The port is not sending or receiving data Blinki ng yellow The port is sending or receiving data Logical Structure Figure 1 39 shows the logical structure of the board Figure 1 39 Logical structure The modules of the board provide the following...

Страница 56: ... Hardware and software compatibility Board Model Spare Parts Model Compatibility Rule SPUA0 SPUA0 Only a board of the same model can be used to replace the SPUA0 You do not need to manually upgrade software Technical Specifications Table 1 33 lists the technical specifications of the SPUA0 Table 1 33 Technical specifications Item Specifications Mechanical specifications Dimensions H x W x D 45 2 m...

Страница 57: ...registered dual in line memory module RDIMM The board offers with the maximum memory capacity of 128 GB Supports 800 MHz 1066 MHz and 1333 MHz RDIMMs Supports error checking and correction ECC Interfacing Provides two 1GE Base ports for communicating with Base planes of multi function switch units MXUs through the backplane Provides two 20GE Fabric ports for communicating with Fabric planes of MXU...

Страница 58: ...i Technologies Co Ltd 54 Function Description Supports serial port redirection Loads board software online Hot swap The boards are hot swappable Appearance The SPUA1s are half width boards and installed in the front service board slots of the subrack Figure 1 40 shows an SPUA1 Figure 1 40 Appearance unit mm Figure 1 41 shows the hardware structure of the SPUA1 ...

Страница 59: ...5 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 55 Figure 1 41 Hardware structure Table 1 35 describes the components of the SPUA1 Table 1 35 Components No Compone nt Quantity Description 1 BMC 1 The BMC a processing module independent from the CPUs implements board management and ...

Страница 60: ...dy Bridge EP CPU 4 Heat sink 1 The heat sink is used to cool CPUs Two CPUs share one heat sink 5 Cover 1 The metal cover is used to protect the components on the board and guide air flows 6 RDIMM 6 Six 16 GB RDIMMs are used to provide 96 GB memory NOTE The RDIMMs are installed close to the CPUs The six RDIMMs are installed in sockets J45 J46 J47 J48 J7 and J8 as shown in Figure 1 41 7 Solid state ...

Страница 61: ...0 10GE or 1GE optical port or electrical port SFP NOTE The ports can be set to the auto negotiation or forced mode 10G BASE R port 1 10GE or 1GE optical port port 2 10GE or 1GE optical port or electrical port port 3 10GE or 1GE optical port port 4 1GE optical port or electrical port SFP NOTE The ports can be set to the auto negotiation or forced mode 1000 BASE T port 5 1GE optical port port 6 1GE ...

Страница 62: ...linking at 4 Hz indicates a critical alarm UID Location indicator Off The indicator is used to locate a device to be operated You can customize the function of this indicator Steady green Blinki ng green OFL Offline indicator Off The board is operating properly Blinki ng blue The board is sending a request for power on or power off or the board is being powered on or off Steady blue The board is p...

Страница 63: ...is in the graceful power off state 0 to 7 Optical port indicator s Green off The link is faulty or disconnected Steady green The link is normal Yello w off The port is not sending or receiving data Blinki ng yellow The port is sending or receiving data Logical Structure Figure 1 45 shows the logical structure of the board Figure 1 45 Logical structure The modules of the board provide the following...

Страница 64: ... software compatibility Board Model Spare Parts Model Compatibility Rule SPUA1 SPUA1 Only a board of the same model can be used to replace the SPUA1 You do not need to manually upgrade software Technical Specifications Table 1 39 lists the technical specifications of the SPUA1 Table 1 39 Technical specifications Item Specifications Mechanical specifications Dimensions H x W x D 45 2 mm x 205 0 mm ...

Страница 65: ...and 1333 MHz RDIMMs Supports error checking and correction ECC Interfacing Provides two 1GE Base ports for communicating with Base planes of multi function switch units MXUs through the backplane Provides two 20GE Fabric ports for communicating with Fabric planes of MXUs through the backplane Provides two 20GE Update interfaces for communicating with the switching planes through the backplane Prov...

Страница 66: ...16 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 62 Appearance The SPUZ0s are half width boards and installed in the front service board slots of the subrack Figure 1 46 shows an SPUZ0 Figure 1 46 Appearance unit mm Figure 1 47 shows the hardware structure of the SPUZ0 ...

Страница 67: ...15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 63 Figure 1 47 Hardware structure Table 1 41 describes the components of the SPUZ0 Table 1 41 Components No Compone nt Quantity Description 1 BMC 1 The BMC a processing module independent from the CPU implements board management and ...

Страница 68: ... 4 Cover 1 The metal cover is used to protect the components on the board and guide air flows 5 RDIMM 3 Three 16 GB RDIMMs are used to provide 48 GB memory NOTE The RDIMMs are installed close to CPU0 The three RDIMMs are installed in sockets J45 J46 and J7 as shown in Figure 1 47 6 Solid state drive SSD 1 The SSD stores the operating system OS and field programmable gate array FPGA files Figure 1 ...

Страница 69: ...P NOTE The ports can be set to the auto negotiation or forced mode 10G BASE R port 1 10GE or 1GE optical port port 2 10GE or 1GE optical port or electrical port port 3 10GE or 1GE optical port port 4 1GE optical port or electrical port SFP NOTE The ports can be set to the auto negotiation or forced mode 1000 BASE T port 5 1GE optical port port 6 1GE optical port or electrical port port 7 1GE optic...

Страница 70: ...linking at 4 Hz indicates a critical alarm UID Location indicator Off The indicator is used to locate a device to be operated You can customize the function of this indicator Steady green Blinki ng green OFL Offline indicator Off The board is operating properly Blinki ng blue The board is sending a request for power on or power off or the board is being powered on or off Steady blue The board is p...

Страница 71: ...is in the graceful power off state 0 to 7 Optical port indicator s Green off The link is faulty or disconnected Steady green The link is normal Yello w off The port is not sending or receiving data Blinki ng yellow The port is sending or receiving data Logical Structure Figure 1 51 shows the logical structure of the SPUZ0 Figure 1 51 Logical structure The modules of the board provide the following...

Страница 72: ...rdware and software compatibility Board Model Spare Parts Model Compatibility Rule SPUZ0 SPUZ0 Only a board of the same model can be used to replace the SPUZ0 board You do not need to manually upgrade software Technical Specifications Table 1 45 lists the technical specifications of the SPUZ0 Table 1 45 Technical specifications Item Specifications Mechanical specifications Dimensions H x W x D 45 ...

Страница 73: ...rate 3 DDR3 memory channels each for installing one 16 GB registered dual in line memory module RDIMM The board offers The maximum memory capacity is 32 GB Supports 800 MHz 1066 MHz and 1333 MHz RDIMMs Supports error checking and correction ECC Ports Provides two 1GE Base ports for communicating with Base planes of multi function switch units MXUs through the backplane Provides two 20GE Fabric por...

Страница 74: ...wer on power off hot swap and reset operations of the board Supports serial port redirection Loads board software online Provides a loading interface for board testing Hot swap The boards are hot swappable Appearance The VPUA0s are half width boards and installed in the front service board slots of the subrack Figure 1 52 shows a VPUA0 Figure 1 52 Appearance unit mm Figure 1 53 shows the hardware ...

Страница 75: ...e SSD 1 The SSD stores the operating system OS and field programmable gate array FPGA files 2 Baseboard managemen t controller BMC 1 The BMC a processing module independent of the CPU implements board management and provides interfaces and buses such as system interfaces General Purpose Input Output GPIO serial ports and Inter Integrated Circuit I2C bus 3 CPU 1 The board uses one Intel Xeon full p...

Страница 76: ...y 2 Two 16 GB RDIMMs are used to provide 32 GB memory 7 Digital signal processing DSP daughter board 1 The DSP daughter board processes voice and video data Figure 1 54 shows the board panel Figure 1 54 Panel 1 SFP optical port 2 Optical port indicators 3 SFP port 4 UID indicator 5 HLY indicator 6 Ejector levers 7 OFL indicator button 8 SFP port 9 SFP optical port Interfaces Figure 1 55 shows the ...

Страница 77: ...o Ltd 73 Figure 1 55 Panel ports Table 1 48 Panel port description Silk Screen Meaning Port Type Standard PORT 0 and 1 10GE media port SFP 10G BASE R PORT 2 and 3 1GE signaling Network File Server NFS interface SFP 1000 BASE X Indicators Figure 1 56 shows the indicators and buttons on the board Table 1 49 describes the indicators and buttons Figure 1 56 Indicators and buttons ...

Страница 78: ...Steady green Blinki ng green OFL Offline indicator Off The board is operating properly Blinki ng blue The board is sending a request for power on or power off or the board is being powered on or off Steady blue The board is powered off The board can be removed at the time Offline button To power off the board hold down this button for 6 seconds until the indicator is blinking blue When the OFL ind...

Страница 79: ...ta service interfaces on the backplane The configuration and control planes configure conversion module chips on the service interface and exchange control plane information with the switch modules The DSP daughter board processes the media data such as the voice and video data The BMC module implements board management and interacts with the backplane through the CAN bus The power module supplies...

Страница 80: ...mm 1 78 in x 8 07 in x 20 91 in Weight 4 0 kg 8 82 lb Electrical specifications Maximum power consumption 200 W Typical power consumption 185 W Power supply Two 48 V DC power supplies provided by the backplane Environmental specifications Temperature Long term operating temperature 0 C to 45 C 32 F to 113 F Short term operating temperature 5 C to 55 C 23 F to 131 F Storage temperature 40 C to 70 C...

Страница 81: ...s two 20GE Fabric ports for communicating with Fabric planes of MXUs through the backplane Provides two 10GE enhanced small form factor pluggable SFP optical ports and two GE SFP optical or electrical ports These four ports are reserved Management function Provides an independently powered baseboard management controller BMC The BMC connects to the SMM through the Network Controller Sideband Inter...

Страница 82: ...oller Hardware Description 1 Service Processing Device Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 78 Figure 1 58 Appearance unit mm Figure 1 59 shows the hardware structure of the VPUA1 ...

Страница 83: ...ents No Compone nt Quantity Description 1 Digital signal processing DSP daughter board 2 The DSP daughter board processes voice and video data 2 Solid state drive SSD 1 The SSD stores the operating system OS and field programmable gate array FPGA files 3 BMC 1 The BMC a processing module independent of the CPU implements board management and provides interfaces and buses such as system interfaces ...

Страница 84: ...sink 1 The heat sink is used to cool the CPU 6 Cover 1 The metal cover is used to protect the components on the board and guide air flows 7 Memory 2 Two 16 GB RDIMMs are used to provide 32 GB memory Figure 1 60 shows the board panel Figure 1 60 Panel 1 SFP optical port 2 Optical port indicators 3 SFP port 4 UID indicator 5 HLY indicator 6 Ejector levers 7 OFL indicator button 8 SFP port 9 SFP opti...

Страница 85: ...o Ltd 81 Figure 1 61 Panel ports Table 1 54 Panel port description Silk Screen Meaning Port Type Standard PORT 0 and 1 10GE media port SFP 10G BASE R PORT 2 and 3 1GE signaling Network File Server NFS interface SFP 1000 BASE X Indicators Figure 1 62 shows the indicators and buttons on the board Table 1 55 describes the indicators and buttons Figure 1 62 Indicators and buttons ...

Страница 86: ...Steady green Blinki ng green OFL Offline indicator Off The board is operating properly Blinki ng blue The board is sending a request for power on or power off or the board is being powered on or off Steady blue The board is powered off The board can be removed at the time Offline button To power off the board hold down this button for 6 seconds until the indicator is blinking blue When the OFL ind...

Страница 87: ... data service interfaces on the backplane The configuration and control planes configure conversion module chips on the service interface and exchange control plane information with the switch modules The two DSP daughter boards process the media data such as the voice and video data The BMC module implements board management and interacts with the backplane through the CAN bus The PSU supplies po...

Страница 88: ...mm 1 78 in x 8 07 in x 20 91 in Weight 5 5 kg 12 13 lb Electrical specifications Maximum power consumption 310 W Typical power consumption 290 W Power supply Two 48 V DC power supplies provided by the backplane Environmental specifications Temperature Long term operating temperature 0 C to 45 C 32 F to 113 F Short term operating temperature 5 C to 55 C 23 F to 131 F Storage temperature 40 C to 70 ...

Страница 89: ...ervice boards Figure 1 64 shows a filler panel installed in the vacant slot for a half width service board Figure 1 64 Filler panel for a half width service board unit mm Interfaces Filler panels provide no port Indicators There is no indicator on filler panels Technical Specifications Table 1 58 lists the technical specifications of filler panels for half width service boards Table 1 58 Technical...

Страница 90: ...0 Session Border Controller Hardware Description 1 Service Processing Device Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 86 Item Specifications Weight 0 6 kg 1 32 lb ...

Страница 91: ...o and visual alarms The universal alarm box adopts a box structure It features advanced technology appropriate layout and high operability serviceability and security The alarm box is generally mounted on the wall in the maintenance and monitoring room Exterior The front panel of the alarm box provides the following components alarm sound indicator alarm severity indicator serial interface communi...

Страница 92: ...m indicator 2 Major alarm indicator 3 Minor alarm indicator 4 Warning alarm indicator 5 Speaker 6 Alarm confirm button 7 Serial communication status indicator 8 Alarm sound turnoff button 9 Alarm sound turnoff indicator Interfaces The side panel of the alarm box provides the following components AC power connector power switch remote speaker interface indicator test button and lock Figure 2 2 show...

Страница 93: ...ators press the button again Except the critical alarm the alarm sound of the major minor and warning alarms cannot be turned on or off by using the alarm sound turnoff button There are four alarm sound turnoff indicators on the alarm box They are EMERGENCY IMPORTANT ORDINARY PROMPTING corresponding to the critical alarm major alarm minor alarm and warning alarm respectively The status of the alar...

Страница 94: ...turnoff button once The alarm sound for the warning alarms is disabled The alarm sound turnoff indicators for the warning alarm and minor alarms are on and other indicators are off Press the alarm sound turnoff button twice The alarm sound for the warning and minor alarms is disabled The alarm sound turnoff indicators for the warning minor major alarms are on and that for the critical alarm is off...

Страница 95: ... m 98 42 ft Maximum distance of the remote speaker 1W active speaker 30 m 98 42 ft 2 2 Optical Module Functions An optical module provides optical to electrical and electrical to optical conversion functions It is connected to an optical fiber to transmit signals Appearance Optical modules can be classified into the following types by encapsulation type small form factor pluggable SFP enhanced SFP...

Страница 96: ...re Description 2 Other Accessories Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 92 Figure 2 3 SFP SFP optical module Figure 2 4 QSFP optical module Figure 2 5 shows the structure of an optical module ...

Страница 97: ... Gbit s The operating wavelength can be 850 nm 1310 nm or 1550 nm The transmission distance can be 550 m 15 km 40 km 80 km or 120 km The transmission distance of an optical module depends on the operating wavelength Table 2 3 lists the mapping between the operating wavelength and the transmission distance Table 2 3 Mapping between the operating wavelength and the transmission distance Operating Wa...

Страница 98: ...al modules Model Trans missio n Rate Gbit s Trans missi on Dista nce km Transm ission Mode Optical Fiber Type Optical Port Parameters Enc aps ulat ion Ty pe Operatin g Tempera ture OMXD3 0008 41 25 0 15 Multimo de Optica l conne ctor type MPO Optica l fiber type multi mode Operating wavelength 850 nm Transmit optical power 7 3 dBm to 1 0 dBm Extinction ratio 3 0 dB Receiver sensitivity 9 5 dBm Ove...

Страница 99: ...e multi mode 850 nm Transmit optical power 9 5 dBm to 2 5 dBm Extinction ratio 9 0 dB Receiver sensitivity 17 0 dBm Overload optical power 0 dBm 4 F to 185 F eSFP 13 10nm 10 00Base Lx SM 1 25 10 00 Single mode Optica l conne ctor type LC Optica l fiber type single mode Operating wavelength 1310 nm Transmit optical power 9 0 dBm to 3 0 dBm Extinction ratio 9 0 dB Receiver sensitivity 20 0 dBm Overl...

Страница 100: ...Bm Extinction ratio 9 0 dB Receiver sensitivity 23 0 dBm Overload optical power 3 0 dBm eSFP 15 50nm 10 00Base Zx FC10 0 1 25 80 00 Single mode Optica l conne ctor type LC Optica l fiber type single mode Operating wavelength 1550 nm Transmit optical power 2 0 dBm to 5 0 dBm Extinction ratio 9 0 dB Receiver sensitivity 23 0 dBm Overload optical power 3 0 dBm eSF P 0 C 70 C 32 F 15 8 F OMXD3 0001 10...

Страница 101: ...y 9 9 dBm Overload optical power 1 0 dBm OSX001 001 10 00 10 00 Single mode Optica l conne ctor type LC Optica l fiber type single mode Operating wavelength 1310 nm Transmit optical power 8 2 dBm to 0 5 dBm Extinction ratio 3 5 dB Receiver sensitivity 12 6 dBm Overload optical power 0 5 dBm SFP 0 C 70 C 32 F 15 8 F OSX080 N00 9 9530 10 3125 80 00 Single mode Optica l conne ctor type LC Optica l fi...

Страница 102: ...ra ture optical power 7 dBm OSX040 N00 9 95 11 10 40 00 Single mode Optica l conne ctor type LC Optica l fiber type single mode Operating wavelength 1550 nm Transmit optical power 4 7 dBm to 4 dBm Extinction ratio 3 dB Receiver sensitivity 14 1 dBm Overload optical power 0 5 dBm SFP 0 C 70 C 32 F 15 8 F 2 3 Electrical Module Functions An electrical module provides optical to electrical and electri...

Страница 103: ... Other Accessories Issue 01 2016 01 15 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 99 Figure 2 7 Electrical module Figure 2 8 shows the structure of an electrical module Figure 2 8 Electrical module structure 1 Handle 2 Spring 3 Label ...

Страница 104: ... and is connected to an Ethernet cable to support the maximum transmission distance of 100 m Technical Specifications Table 2 5 describes the technical specifications of an electrical module Table 2 5 Technical specifications of an electrical module Model Transmissi on Rate Mbit s Transmis sion Distance km Port Type Encap sulati on Operating Temperature SFP 1000Bas eT 10 1000 auto negotia tion 0 1...

Страница 105: ...t terminal on a subrack to the power output terminal on the power distribution box PDB to supply power to the subrack A PGND cable connects the ground point on a subrack to the ground point on a mounting bar of the cabinet for proper grounding Appearance Power cable Power cable with OT terminals Both ends of a power cable are OT terminals The blue cable is connected to the NEG terminal and the bla...

Страница 106: ...als AC power cable Most countires have their own AC power cables including China Europe and North America The delivered AC power cables must comply with local standards The following uses China AC power cables as an example AC power cables include the AC power cable using the C13 straight female SF and the PI straight male SM and the AC power cable using the C13 angled female AF and the C14 SM The...

Страница 107: ... shows a PGND cable with OT terminals Figure 3 5 PGND cable with OT terminals PGND cable with dual hole JG terminals Each subrack is configured with one PGND cable The cable is yellow and green Both ends of the PGND cable are dual hole JG terminals Figure 3 6 shows a PGND cable with dual hole JG terminals Figure 3 6 PGND cable with dual hole JG terminals The subrack used in North America uses powe...

Страница 108: ...he Alarm Box Functions The power cables are used for supplying power to the alarm box Table 3 2 lists the configuration of the power cables Table 3 2 Configuration of the power cables Power Supply Quantit y Remarks AC power supply 1 The cable is configured only if system down notification is required for the alarm box If the length of the cable is not sufficient connector boards must be added The ...

Страница 109: ... the other end is two 1 pin connectors Voltage 48 V Length 30 m 98 42 ft The length varies according to the actual situation Gauge 0 8 mm2 0 001 in 2 Color black 3 2 Signaling Cables 3 2 1 Ethernet Cable Functions Ethernet cables are used for cascading devices or for communication between devices and the network Through Ethernet cables devices can be locally serviced and remotely accessed over the...

Страница 110: ...Proprietary and Confidential Copyright Huawei Technologies Co Ltd 106 Figure 3 7 Ethernet cable appearance Figure 3 8 shows the structure of an Ethernet cable Figure 3 8 Ethernet cable structure Pinouts Figure 3 9 shows the pins at both ends of a straight through cable Table 3 4 describes the pins ...

Страница 111: ...ables 2 2 Orange 3 3 White and green A pair of twisted pair cables 6 6 Green 5 5 White and blue A pair of twisted pair cables 4 4 Blue 7 7 White and brown A pair of twisted pair cables 8 8 Brown Technical Specifications Table 3 5 lists the technical specifications of the Ethernet cable Table 3 5 Technical specifications of the Ethernet cable Item Specifications Connectors X1 and X2 RJ45 Number of ...

Страница 112: ...an choose single mode or multi mode optical cables based on site requirements Figure 3 10 LC PC LC PC multi mode optical cable An LC PC connector is used at both ends of an LC PC LC PC multi mode optical cable Figure 3 11 shows an LC PC connector Figure 3 11 LC PC connector Technical Specifications The LC PC LC PC multi mode optical cables comply with ITU G651 and GB T 12357 Table 3 6 lists the te...

Страница 113: ...tical fiber core 62 5 125 um Outer diameter of an optical cable 2 0 mm 0 08 in Service life 500 times 3 2 3 DLC PC DLC PC Multi Mode Optical Cable Functions The DLC PC DLC PC multi mode optical cables are used to connect LAN switches or disk arrays to other network devices Exterior Figure 3 12 shows the exterior of a DLC PC DLC PC multi mode optical cable Figure 3 12 Exterior of a DLC PC DLC PC mu...

Страница 114: ...ssion mode Multi mode Number and type of optical connector I DLC PC Number and type of optical connector II DLC PC Diameter of the optical fiber core 62 5 125um Outer diameter of an optical fiber 2 0 mm 0 08 in Optical fiber length 5 0 m 16 40 ft Service life times 500 Net weight 0 048 kg 0 106 lb Lowest operating environment temperature 20 degC Highest operating environment temperature 70 degC 3 ...

Страница 115: ...ector Technical Specifications The LC PC LC PC single mode optical cables comply with ITU G 652 and GB T 9771 1 Table 3 8 lists the technical specifications of the LC PC LC PC single mode optical cable Table 3 8 Technical specifications of the LC PC LC PC single mode optical cable Item Specifications Cable type Optical jumper Transfer mode Single mode Number and type of optical connector I LC PC N...

Страница 116: ...tical cables are used to connect the optical ports on two devices for data communications The MPO PC MPO PC multi mode optical cables transmit 41 25 Gbit s signals Appearance The MPO PC MPO PC multi mode optical cable is cyan as shown in Figure 3 15 Figure 3 15 MPO PC MPO PC multi mode optical cable An MPO PC connector is used at both ends of an MPO PC MPO PC multi mode optical cable Figure 3 16 s...

Страница 117: ...m Specifications Cable type Optical cable component Transfer mode Multi mode Number and type of optical connector I MPO PC Number and type of optical connector II MPO PC Diameter of the optical fiber core 50 um 125 um Number of optical fiber cores 8 Outer diameter of an optical cable 3 5 mm 0 14 in Optical cable length 2 m 78 74 in 30 m 1181 1 in or 100 m 3937 in Service life 200 times 3 2 6 High ...

Страница 118: ...ns Figure 3 18 shows the pins at both ends of a high density cable Table 3 10 lists the technical specifications of the high density cable Figure 3 18 Pins at both ends of a high density cable unit mm Table 3 10 Technical specifications of the high density cable Item Specifications X1 Cable connector MDR 26 pin male cable solder type for OEM X2 Cable connector D connector 15 pin female connector c...

Страница 119: ... female connector W1 2 Twisted pair cable 100 ohms SEYVP 0 48 mm 26 AWG 4 pairs black W3 4 Twisted pair cable 100 ohms SEYVP 0 48 mm 26 AWG 2 pairs black 3 2 7 DB9 RJ45 Serial Cable Functions The DB9 RJ45 serial cable is used for data transmission It has a DB9 connector at one end and an RJ45 connector at the other end The DB9 connector connects to the serial port of a client and the RJ45 connecto...

Страница 120: ... X2 3 TX X1 3 X2 6 RX X1 5 X2 5 GND Technical Specifications Table 3 12 lists the technical specifications of the DB9 RJ45 serial cable Table 3 12 Technical specifications of the DB9 RJ45 serial cable Item Specifications Connector type Cable Connector 04040838 D Connector 9PIN Female Connector Cable Welding Type Network Interface Connector Single Row Single Interface 8PIN 8bit Shielded Crystal Con...

Отзывы: