oam-mgr
oam-bind ingress efm interface Ethernet0/0/1 egress cfm md md1 ma ma1
oam-bind ingress cfm md md1 ma ma1 egress efm interface Ethernet0/0/2
#
----End
4.15 Configuring Association Between Ethernet CFM and
Ethernet CFM
This section describes how to configure association between Ethernet CFM and Ethernet CFM.
4.15.1 Establishing the Configuration Task
Applicable Environment
IEEE 802.1ag is designed for a group of services or certain network devices to detect faults on
the network. IEEE 802.1ag is used between CE devices, PE devices, or CE and PE devices. As
shown in
, Ethernet CFM runs between CE1 and PE1, and between CE2 and PE2;
Ethernet CFM runs between CE1 and CE2. After Ethernet CFM is associated with Ethernet
CFM, the Ethernet CFM module can detect faults on the link between CE1 and PE1 and notify
CE2.
Figure 4-11
Networking diagram for configuring association between Ethernet CFM and
Ethernet CFM
Ethernet CFM
Ethernet0/0/1
CE1
PE1
PE2
CE2
Ethernet CFM
Ethernet CFM
Ethernet0/0/1
Ethernet0/0/2
Ethernet0/0/2
Pre-configuration Tasks
Before configuring association between Ethernet CFM and Ethernet CFM, complete the
following task:
l
4.8 Configuring Basic Ethernet CFM
Data Preparation
To configure association between Ethernet CFM and Ethernet CFM, you need the following
data.
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
4 Ethernet OAM Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
206