interface
interface-type2
interface-number2
specifies the interface associated with the EFM
OAM session.
NOTE
If Step 5 is performed, both the
oam-bind ingress efm interface
md-name
ma
ma-name
trigger if-
down
egress
interface
interface-type
interface-number
command and the
oam-bind ingress interface
interface-type interface-number
egress
cfm
md
md-name
ma
ma-name
trigger
if-down
command are
displayed in the configuration file, indicating fault notification in opposite directions.
----End
4.7.3 Checking the Configuration
After the association between an EFM OAM session and an interface is successfully configured,
you can view the association configuration in the OAM management view.
Prerequisite
All configurations of the association between an EFM OAM session and an interface are
complete.
Procedure
Step 1
Run the
display this
command in the OAM management view to check whether an EFM OAM
session and an interface are successfully associated.
----End
Example
Run the
display this
command. You can view all associations between EFM OAM sessions and
interfaces.
[Quidway-oam-mgr]
display this
#
oam-mgr
oam-bind ingress interface GigabitEthernet0/0/1 egress efm interface
GigabitEthernet0/0/2 trigger if-down
oam-bind ingress efm interface GigabitEthernet0/0/2 trigger if-down egress
interface GigabitEthernet0/0/1
#
return
4.8 Configuring Basic Ethernet CFM
By configuring basic Ethernet CFM functions, you can implement end-to-end detection,
advertisement, verification, and location of connectivity faults.
4.8.1 Establishing the Configuration Task
Before configuring basic Ethernet CFM functions, familiarize yourself with the applicable
environment, complete the pre-configuration tasks, and obtain the required data. This can help
you complete the configuration task quickly and accurately.
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
4 Ethernet OAM Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
175