28/29 >>
Aligning Antennas
Relationship Between RSSI Port Voltage and Receive Signal Level
Moistureproofing the Connectors of GE(o), COMBO, GE(e) and P&E ports
1. Wrap one layer of PVC tape around the exposed part of the group clip.
2. Wrap three layers of waterproof insulation tape outside the PVC tape.
3. Wrap three layers of PVC tape outside the waterproof insulation tape.
4. Secure the tape by using outdoor binding straps at the positions 1 cm to the wrapping edges.
Appendix
Connect GE ports to the RTN 380e and then moistureproof them.
Waterproof insulation tape
For details on how to use the
waterproof insulation tape, see
instructions provided by the tape
vendor.
Waterproofing the Ground Clip
Moistureproof a connector as follows:
1. Wrap one layer of PVC tape around the moistureproofed part.
2. Wrap one layer of waterproof insulation tape outside the PVC tape. Ensure that the waterproof insulation tape completely
covers the PVC tape (including the edges).
3. Wrap one layer of PVC tape outside the waterproof insulation tape.
4. Secure the tape by using outdoor binding straps at the positions 1 cm to the wrapping edges.
Length between the root of the GE(o)
/COMBO port connector and the
lower edge of the moistureproofed
part: 30 mm
Moistureproofed part
PVC tape
30 mm
30 mm
30 mm
Root
Root
The entire GE(e)/P&E port
connector and the length between
the root of the connector and the
lower edge of the moistureproofed
part: 30 mm