The IFS06 supports at least three RRUs when the ambient temperature is higher than or
equal to the lowest operating temperature of the RRUs and at least 5°C (41°F) lower than
the highest operating temperature of the RRUs. The IFS06 supports a maximum of six
RRUs when the ambient temperature is higher than or equal to the lowest operating
temperature of the RRUs and at least 10°C (50°F) lower than the highest operating
temperature of the RRUs.
For details about the operating temperature of the RRUs, see section "Technical Specifications of RRUs"
in
Base Station Technical Description
.
RRUs cannot be stacked when the RRUs are installed on an IFS06, as shown in Figure 3-18.
Figure 3-18
Correct installation of RRUs installed on an IFS06
Figure 3-19 and Figure 3-20 show RRUs installed on an IFS06.