Silkscree
n
Color
Status
Description
Blinking (on for
1s and off for 1s)
An alarm is generated. The alarm may be
caused by a fault on a related board or port.
Therefore, you need to locate the fault before
deciding whether to replace the module.
Steady off
No alarm is generated.
ACT
Green
Steady on
The module is running properly with TX
channels enabled or the software is being
loaded without RRU running.
Blinking (on for
1s and off for 1s)
The module is running properly with TX
channels disabled.
VSWR
Red
Steady off
No Voltage Standing Wave Ratio (VSWR)
alarm is generated.
Blinking (on for
1s and off for 1s)
VSWR alarms are generated on the
ANT_TX/RXB port.
Steady on
VSWR alarms are generated on the
ANT_TX/RXA port.
Blinking (on for
0.125s and off for
0.125s)
VSWR alarms are generated on the
ANT_TX/RXA and ANT_TX/RXB ports.
CPRI0/IR0
Red or
green
Steady green
The CPRI link is functioning properly.
Steady red
An optical module fails to transmit or receive
signals because the optical module is faulty
or the fiber optic cable is broken.
Blinking red (on
for 1s and off for
1s)
The CPRI link is out of lock because of
mutual lock of dual-mode clock sources or
mismatched data rates over CPRI ports.
Steady off
The optical module cannot be detected, or the
CPRI cable is not connected properly.
CPRI1/IR1
Red or
green
Steady green
The CPRI link is functioning properly.
Steady red
An optical module fails to receive signals
because the optical module is faulty or the
fiber optic cable is broken.
Blinking red (on
for 1s and off for
1s)
The CPRI link is out of lock because of
mutual lock of dual-mode clock sources or
mismatched data rates over CPRI ports.
Steady off
The optical module cannot be detected, or the
CPRI cable is not connected properly.
RRU3942
Hardware Description
2 RRU Introduction
Issue 02 (2012-06-29)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10